• Title/Summary/Keyword: 대지

Search Result 812, Processing Time 0.033 seconds

Numerical Quadrature Techniques for Inverse Fourier Transform in Two-Dimensional Resistivity Modeling (2차원 전기비저항 모델링에서 후리에역변환의 수치구적법)

  • Kim, Hee Joon
    • Economic and Environmental Geology
    • /
    • v.25 no.1
    • /
    • pp.73-77
    • /
    • 1992
  • This paper compares numerical quadrature techniques for computing an inverse Fourier transform integral in two-dimensional resistivity modeling. The quadrature techniques using exponential and cubic spline interpolations are examined for the case of a homogeneous earth model. In both methods the integral over the interval from 0 to ${\lambda}_{min}$, where ${\lambda}_{min}$, is the minimum sampling spatial wavenumber, is calculated by approximating Fourier transformed potentials to a logarithmic function. This scheme greatly reduces the inverse Fourier transform error associated with the logarithmic discontinuity at ${\lambda}=0$. Numrical results show that, if the sampling intervals are adequate, the cubic spline interpolation method is more accurate than the exponential interpolation method.

  • PDF

A Divece for Reducing the Zero phaze Harmonics of Neutral Line of Power Facility (전기수용설비의 중성선 영상분고조파전류저감장치)

  • Kang, Chang-Won;Choi, Gil-Soo;Han, Sung-Bae;Kim, Bum-Soo;Chung, Yeon-Hae;Lee, Ki-Cheol
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.43-48
    • /
    • 2001
  • Wide use of non-linear loads such as personal computers, monitors, laser printers, variable speed drives, UPS systems and other electronic equipment have led to harmonics becoming #1 issue in the electrical industry today. Commercial and Industrial building power distribution systems, designed for the old, linear-style loads especially when found in high densities. Some common power system problems include overloaded neutral conductors, overheated distribution transfOlmers, high neutral-to-ground voltage, poor power factor and distortion of the voltage waveform supplying these loads. The power quality problems, particularly high voltage distortion, have been known to cause equipment downtime due to malfunctions and component failure.

  • PDF

Measurement and Analysis of Earth Resistivity for the Substation Grounding Design (변전소 접지설계를 위한 대지고유저항의 측정과 해석)

  • Han, P.;Kim, J.Y.;Choi, J.K.;Jung, G.J.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.807-812
    • /
    • 1997
  • For an equivalent uniform soil model to multiple-layered soil structure, ground depth, which is used in the calculation of equivalent resistivity, should be varied according to the size of grounding area. In case of 150 kV substation grounding design, 15 m of ground depth has been used and 25 m for 345 kV, But applying these ground depths can lead to errors in grounding resistance calculation, and these errors are coming from the poor representation of those depths to real soil resistivities. In this paper, the soil resistivity measurement techniques by Wenner method and grounding resistance calculation results by computer simulation were presented. Case studies contain the area from 3,000 to $30,000\;m^2$ and measuring space from of m to $100{\sim}250\;m$, Based of the computation results, 50 m, 60 m and 80 m of ground depth for less than 30, 40 and 70 m of equivalent hemispherical radius were proposed respectively.

  • PDF

Rheological Properties of Various Gelatinized Potato Starch Pastes (품종별 감자 전분 호화액의 리올로지 특성)

  • 정란희;김경애
    • Korean journal of food and cookery science
    • /
    • v.7 no.3
    • /
    • pp.1-6
    • /
    • 1991
  • Potato starches are obtained from Irish Cobbler (the dry type), Shepody and superior (the intermediate type) and Dejima (the moist type). Rheological properties of heat-gelatinized potato starch paste were studied to elucidate difference of various potato starches. Heat-gelatinized 3 to 7% potato starch paste showed pseudo plasticity in yield stress. As starch paste concentration increased, the values of consistency index was increased. Relationship between logarithmic consistency index and concentration of potato starch paste was linear at 5% starch concentration. Concentration dependence of consistency index and yield stress of Shepody was highest. As measuring temperature increased, the value of consistency index was decreased. Irish Cobbler starch paste at $50^{\circ}C$, Shepody, Superior and Dejima starch paste at $60^{\circ}C$ showed linear relationships with different slopes. The activation energies of Shepody starch paste was 3.97㎉l/㏖.

  • PDF

Examinations on the Reasonable Measuring Methods of the Soil Resistivity for Design of Grounding System (접지시스템의 설계를 위한 대지저항률의 합리적인 측정방법 고찰)

  • Lee, Bok-Hee;Kim, Ki-Bok;Lee, Seung-Hoon;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.35-41
    • /
    • 2011
  • In order to design effectively the grounding system, it is very important to determine the optimum soil resistivity at the desired location of the connection to earth. This paper deals with the reasonable methods of measuring the soil resistivity where grounding electrodes are buried. The soil resistivity at three test sites with different resistivity of soil were measured as functions of the spacing between the test probes in the Wenner's four-point method and the length of test ground rod in the three-point method. In the case of the three-point method, the length of test ground rod of 2-10[m] in length was appropriate in two-layered soil structure. In the length range of 2-10[m], the results measured by the three-point method using the test ground rod with the length corresponding to the spacing between the test probes of the Wenner's four-point method are in good agreement with the data obtained from the Wenner's four-point method.

Grounding Characteristics Analysis of the Stainless-steel Plate Grounding Electrode for Distribution Poles (배전전주용 스테인리스강판 접지전극의 접지 특성분석)

  • Kim, Kyung-Chul;Lee, Kyu-Jin;Kim, Min-Sung;Jung, Ji-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.94-100
    • /
    • 2010
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents or transient currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the grounding resistance, grounding impedance and transient grounding impedance are measured by using 3-point fall-of-potential method in order to analyse grounding characteristics of the stainless-steel plate grounding electrode. An equivalent transfer function model of the grounding impedance and transient grounding impedance are identified from the measured values by using ARMA method and evaluated by comparing conventional grounding impedances.

Electric Leakage Point Detection System of Underground Power Cable Using Half-period Modulated Transmission Waveform and Earth Electric Potential Measurement (반주기 변조된 송신파형과 대지전위 측정을 이용한 지중 케이블 누전 고장점 탐지 시스템)

  • Jeon, Jeong Chay;Yoo, Jae-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2113-2118
    • /
    • 2016
  • The precise detection of electric leakage point of underground power cable is very important to reduce cost and time of maintenance and prevent electric shock accident through expedite repair of electric leakage point. This paper proposes a electric leakage point detection system underground power cable using of half-period modulated transmission waveform and earth electric potential measurement. The developed system is composed of transmitter to generate the wanted pulse waveform, receiver to measure and display earth electric potential by the transmitted pulse in electric leakage point and PC Software program to display of GPS coordinate on detection cable line. The performance of the electric leakage point detection system was tested in the constructed underground cable leakage detection test bed. The test results on signal generation voltage precision of signal transmitter, mean detection earth voltage, mean detection leakage current and electric leakage point detection error showed the developed system can be used in electric leakage point detection underground power cable.

Natural Period Estimation for the Buildings of Upper Wall and Lower Frame Type (상부벽식-하부골조를 가진 복합구조물의 고요주기예측)

  • 박기수;김희철;김종헌
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.1-13
    • /
    • 2000
  • 상부벽식 하부골조를 가진 복합구조물은 부족한 대지를 효율적으로 활용하기 위하여 건설되고 있다. 이러한 복합건물은 상부벽식-하부골조를 가지는 구조로써 일반적으로 전이보 또는 전이판으로 상하부를 연결하고 있다. 따라서 상하부 구조사이의 강성과 질량에 많은 차이가 발생하게 된다. 구보물의 고유주기는 지진하중과 밑면전단력을 결정하기 위한 중요한 변수이다. 그러나 현재 국내 규준에서 제안하는 고유주기 산정식은 이러한 건물에는 적용할 수 없다. 본 연구에서는 상부벽식-하부골조를 가진 복합구조물의 고유주기의 산정에 영향을 미치는 변수들 중 가장 큰 영향을 미치는 건물의 상하부 층수에 따른 변수만을 고려하여 고유주기산정식을 제안하였다. 하부는 2~5개 층을 가지고, 상부는 10~18개 층을 가지는 15~20층의 건물이면 정형적인 평면을 가지는 복합구조물로 한정하였다. 건물 내부의 채움벽에 대한 효과를 고려한 고유주기 제안식은 다음과 같다. 장변 방향 : $T_{L}$=($0.20H_{h}+0.05H_{i}$)/$sqrt{B}$-0.42 단변 방향 :$T_{S}$=($0.07H_{h}+0.12H_{i}$)/$sqrt{B}$-0.40

  • PDF

A Study on the Problems of elementary School Safety and its Improvement in Korea (우리나라 초등학교 학교안전의 문제점 및 개선방향에 관한 연구)

  • Yoon, Yong-Gi
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.3
    • /
    • pp.1-14
    • /
    • 2014
  • This research aims to orientation for new ways to improve school safety environment composition : The first study was the survey of various literature and status on primary school safety has been established in residential developments in urban areas were investigated and analyzed. This study was constructed as follows : The first chapter of the study is composed with the purpose, contents and configuration of study, definitions of terms, and consists of a limitation of such studies. And in chapter 2, we define such concepts, the range of school safety incidents. In Chapter 3, the nation's school safety situation was investigated, And in the fourth chapter introduced the practice of foreign school safety plan, Chapter 5 was to provide direction for future school safety and accident prevention plan. Including 12 new elementary school in Dongbaek district and Dongtan New-Town 20 new elementary schools in the metropolitan area of New-City were examined for safety issues, such as the environment of school, school zones, school premises form compositions and its outdoor and indoor facilities. This study was aimed at some of the nation's metropolitan New Town Elementary School. Therefore, there is a limit to this generalization. Also planned construction safety plan elements for the indoor facilities are further studies are needed for this hayeoteumeuro excluded. In addition, the architectural planning elements of the school safety needs additional studies is excluded.

The Planning Graph for Estimating Capacity of Rainwater Utilization Cisterns (엑셀 기반의 저류시설 용량 계획선도 개발 및 적용)

  • Kim, Ree-Ho;Kim, Young-Min;Lee, Sang-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.832-836
    • /
    • 2010
  • 물 부족에 대비한 대체수자원 개발과 함께 최근 들어 환경성과 생태계를 고려한 녹색도시 조성이 부각되면서 빗물이용을 통한 용수확보가 지속적으로 추진되고 있다. 녹색도시 조성은 조경시설 및 수경시설에서의 용수 사용량을 증가시키므로 용수확보에 대한 부담을 경감시키고 대상 사업의 환경성을 강조하기 위한 것으로 판단된다. 그러나 최근의 빗물이용시설의 도입 현황을 살펴보면 설계 시 집수면적이나 대지면적의 일정비율 이상을 설치하는 간편식이 주로 이용하고 있다. 간편식을 이용한 방법은 집수면의 토지이용 특성, 물 사용량을 고려할 수 없기 때문에 시설이 설치된 후 운영효율 저하가 우려된다. 본 연구에서는 간편식 법의 문제점 개선과 함께 시설 설계 시 편리하게 활용할 수 있도록 엑셀기반의 저류용량 계획선도를 개발하였다. 본 계획선도는 대상지역의 강우량과 토지이용 특성을 입력한 후 용수 공급 패턴(매일 일정량 활용, 무강우 시 일정량 활용, 하절기에 중점적으로 활용)에 따라 빗물이용시설 용량을 결정할 수 있다. 인터넷을 통해 기상청 등의 강우자료 서비스가 진행 중이므로 공간적인 제약 없이 전국적으로 활용도가 높을 것으로 기대된다.

  • PDF