• Title/Summary/Keyword: 대지저항률

Search Result 50, Processing Time 0.029 seconds

Apparent Soil Resistivity Calculation Using Complex Image Method (복소수이미지 방법을 이용한 겉보기 대지저항률 계산)

  • Kim, Ho-Chan;Boo, Chang-Jin;Kang, Min-Jae
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.318-321
    • /
    • 2019
  • The apparent soil resistivity is used for estimating multilayer soil parameters, such as, layer's depth and soil resistivity. The apparent soil resistivity can be measured, and also can be calculated if soil parameters are given, becacuse the apparent soil resistivity is a function of these parameters. Therefore, any optimization algorithms can be used to find these parameters which make the calculated apparent soil resistivity close to the measured one. The equation for calculating the apparent soil resistivity is complicated and time consumed, because it is composed of an infinite integral which includes a zero order Bessel's function of the first kind. In this paper, a fast algorithm for calculating the apparent soil resistivity of horizontal multilayer earth structure has been presented using complex image method.

Frequency-Dependent Grounding Impedances of Counterpoises Associated with Soil Resistivity (대지저항률에 따른 매설지선의 접지임피던스의 주파수의존성)

  • Kim, Tae-Ki;Choi, Young-Chul;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.114-121
    • /
    • 2010
  • This paper deals with the frequency-dependent grounding impedances of counterpoises relevant to the soil resistivity, the length of counterpoises and the feeding point of test current. The grounding impedances of counterpoises buried in one-layered and two-layered soils were measured and analyzed in the frequency range from 1[kHz] to 10[MHz]. As a result, the frequency-dependent grounding impedances strongly depend on the soil resistivity, and the grounding impedances within the frequency of several tens [kHz] are capacitive behavior in high soil resistivity. When injecting the ground current to the end of counterpoise buried in soil with high resistivity, the grounding impedances in high frequency are increased.

Design of optimum grounding system for reserved area of wind turbine system by the ground resistivity measurement and analysis (풍력개발예정지에 대한 대지저항률 측정과 해석을 통한 최적 접지설계)

  • Chang, Jeong-Ho;Choi, Hyeong-Cheol;Lee, Kwang-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.321-323
    • /
    • 2008
  • 전력설비에 대한 접지시스템의 근본 목적은 인체에 대한 안정성의 확립과 설비의 기능 향상을 위하여 사고 발생 시 고장 전류를 대지로 안전하고 신속하게 방전시키는데 그 목적이 있다. 풍력발전기 접지설계 시 고려해야 할 중요한 설계 요소는 토양조건, 대지저항률의 측정과 분석, 고장전류, 안전전압 결정 등이 있으며, 이러한 설계 파라미터 가운데 대지저항률은 접지설계 방법 및 물량에 미치는 영향이 결코 작지 않으므로 이에 대한 정확한 측정과 분석을 통하여 효율적인 접지 설계를 시행할 수 있어야 한다.

  • PDF

The method of ground connection system design due to the difference of earth restivity (대지저항률 변화에 따른 접지설계 기법)

  • Han, C.D.;Choi, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.224-225
    • /
    • 2006
  • 접지설비는 전력계통의 안정적인 운전을 유지하고 사고시 고장전류를 대지로 안전하게 방전시켜 사람과 전기설비의 안전을 확보하는 데 그 목적이 있다. 접지설계시 대지저항률은 중요한 설계인자로 대지저항률 변동에 따른 접지설계 방법을 접지 설계프로그램을 이용하여 비교, 분석하였다.

  • PDF

Conventional Grounding Impedance according to the Length and Soil Resistivity of the vertical grounding electrode (수직접지전극의 길이와 대지저항률에 따른 규약접지임피던스 분석)

  • Choi, Jong-Hyuk;Shin, Hee-Gyung;Lee, Bok-Hee;Kim, Tae-Ki;Ahn, Chang-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1568-1569
    • /
    • 2011
  • 최근 기후변화로 인해 낙뢰의 발생빈도가 크게 증가하고 있으며 이에 따라 피뢰시스템의 중요성이 부각되고 있다. 피뢰시스템의 원활한 기능을 수행하기 위해 접지시스템의 성능이 보장되어야 하며, 접지전극은 뇌격전류를 안전하게 대지로 방류시켜야 한다. 본 논문에서는 피뢰시스템에서 가장 흔하게 사용되는 수직접지전극을 대상으로 서지전류가 인가되었을 때 접지전극이 묻힌 대지저항률, 접지전극의 길이, 서지 전류의 파두시간 등에 따른 규약접지임피던스를 측정하고 그 특성을 분석하였다. 그 결과 대지저항률이 높은 토양과 접지전극의 길이가 짧은 경우 접지임피던스가 감소하는 용량성 특성이 지배적으로 나타나며, 대지저항률이 작고 접지전극의 길이가 긴 경우 접지임피던스가 증가하는 유도성 특성이 지배적으로 나타났다. 따라서 피뢰시스템을 위한 접지시스템 설계 시 대지저항률 및 접지전극의 길이를 고려하여 유도성 특성을 최소화 할 수 있도록 설계해야 한다.

  • PDF

Design of Grounding System for Rock Area by Ground Resistivity measurement (암반지형에서의 대지저항률 측정을 통한 접지설계)

  • Lee, Jeong-Hun;An, Ho Sung;Maeng, JongHo;Mun, Seong Duk;Ahn, Heesung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.394-395
    • /
    • 2015
  • 접지시스템은 전력계통에서 사고가 발생하거나 접지가 시공된 시설물에 낙뢰가 침입하는 경우와 같이 고장 전류나 써지가 발생하였을 때 대지로 신속하게 방전시켜 전력기기의 파손 및 고장을 방지하고 대지 전위 상승을 억제하여 인체에 대한 안전성을 확보를 해야한다. 본 논문에서는 대지저항률이 높은 암반지형에서 접지시스템을 설계하기 위해서 대지저항률을 측정하여 토양모델을 모의하였으며, 접지망 설계를 통해 대지 전위 상승을 모의하여 인체 안전 측면을 검토하고자 한다.

  • PDF

Determining Kernel Function of Apparent Earth Resistivity Using Linearization (선형화를 이용한 대지저항률의 커널함수 결정)

  • Kang, Min-Jae;Boo, Chang-Jin;Lee, Jung-Hoon;Kim, Ho-Chan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.454-459
    • /
    • 2012
  • A kernel function of apparent earth resistivity can be estimated using the apparent earth resistivity measured with Wenner's 4 point method. It becomes to solve a nonlinear system to estimate the kernel function of apparent earth resistivity. However it is not simple to get solution of nonlinear system with many unknown variables. This paper suggests the method of estimating kernel function by linearizing this nonlinear system. Finally, various examples of earth structure have been simulated to evaluate the proposed method in this paper.

Comparison Analysis of Soil Structure Methods for Deciding the Position of a Deeply Driven Ground Rod (심매설 접지봉의 위치결정을 위한 대지구조 분석 방법들의 비교분석)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.37-45
    • /
    • 2007
  • Recently, there has been an increase of the use of ground system for lightning protection called deeply driven grounding electrode. In the case of deeply driven grounding electrode, the rod electrode is equipped perpendicularly and deeply, therefore, it has a benefit to have less restriction of place compared to mesh grid electrode. However, ground impedance is largely changed by the local earth resistivity, so it requires a detailed analysis of the ground structure when planning. The measurement of earth resistivity by existing Wenner's method has been widely used, however, this method can not find out a change in the local ground resistance and it shows the result outwardly to be difficult to estimate exact depth. Therefore, this study analyzed the ground structure as 2-D image using 96 channels measurement facility and tried to analyze change in the local ground resistance and depth of the ground in order to design a deeply driven electrode effectively for lightning protection. It used Wenner alpha method dipole-dipole method and Schlumberger method for 2-D image analysis of the ground resistivity ma based on, it the result was compared with the ground structure analyzed with the result using the CDEGS and Wenner 1-D method.

Comparison of Grounding System Performance by Analysing Soil Laver Structures (대지지층구조의 분석유형에 따른 접지성능 비교 평가)

  • Cho, D.H.;Lee, K.S.;Jung, C.H.;Rhee, E.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.80-83
    • /
    • 2009
  • 현장 대지구조의 측정과 분석은 정확하고 신뢰성 있는 접지시스템의 설계와 시공에 매우 중요하며, 특히 대지 구조의 분석은 접지방식의 선정과 시공에 있어 절대적인 요소이다. 현장 측정 대지저항률의 실제적 분석을 통해 더 정확한 접지설계와 접지의 효율성을 높일 수 있으며, 시공 후 접지성능의 설계 오차를 최소화할 수 있게 된다. 대지는 다양한 형태의 지층과 구조로 이루어져 있으며, 접지설계의 신뢰성과 정확성은 대지 조건을 얼마나 현장 지질 조건에 가깝게 모델링 하는가에 달려있다. 현장 대지구조 및 지질 특성에 가깝게 분석하여 적용된 접지 설계는 시공 오류의 최소화, 성능의 안정화 그리고 비용의 절감은 물론 운용 설비의 운용 품질을 높여 주게 된다. 본 연구에서는 현장에서 측정된 대지저항률을 수직 지층와 수평지층 구조로 분석하여 그 결과를 비교하였고, 분석된 각각의 구조 대지저항률을 적용하여 접지시스템을 설계 비교하였다. 또한 설계된 접지시스템을 현장에 시공하여 측정된 결과값을 수직구조의 접지 설계치와 수평구조의 접지 설계치를 비교하므로써, 이를 통해 대지구조의 유형분석에 따른 접지설계의 신뢰성과 오류를 최소화하기 분석방안을 제시하였다.

  • PDF

Development of Smart Multi-function Ground Resistivity Measuring Device using Arduino in Wind Farm (풍력 발전단지내 아두이노를 활용한 스마트 다기능 대지 고유 저항 측정 장치 개발)

  • Kim, Hong-Yong;Yoon, Dong-Gi;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.65-71
    • /
    • 2019
  • Conventional methods of measuring ground resistance and ground resistance field measurement are used to measure voltage drop according to the resistance value of the site by applying current by installing a constant interval of measurement electrode. If the stratified structure of the site site is unique, errors in boundary conditions will occur in the event of back acid and the analysis of the critical ground resistance in the ground design will show much difference from simulation. This study utilizes the Arduino module and smart ground measurement technology in the convergent information and communication environment to develop a reliable smart land resistance measuring device even if the top layer of land is unique, to analyze the land resistance and accumulate data to predict the change in the age of the land. Considering the topographical characteristics of the site, we propose a ground resistance measuring device and its method of measuring ground resistance so that the auxiliary electrode can be installed by correctly positioning the angle and distance in measuring ground resistance. Not only is ground resistance value obtained through electrodes installed to allow accurate ground resistance values to be selected, but it can also be used as a useful material for installing electrical facilities in similar areas. Moreover, by utilizing reliable data and analyzing the large sections of the site, a precise analysis of the site, which is important in ground design as well as construction cost, is expected to be used much in ground facility design such as potential rise.