Shin, Sang-Ho;Jung, Dong-Soo;Kim, Chong-Bo;Seo, Tae-Beom;Chun, Won-Gee;Auh, P. Chung-Moo
Solar Energy
/
v.17
no.4
/
pp.23-33
/
1997
In this paper, performance of various working fluids is evaluated for the closed Ocean Thermal Energy Conversion(OTEC) power plant operating on Rankine cycle. The evaporator and condenser are modeled via UA and LMTD method while turbine and pump are modeled by specifying isentropic efficiencies. R22, Propane, Propylene, R134a, R125, R143a, R32, R410A and Ammonia are used as working fluids. Results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. The superheat at the evaporator exit and subcooling at the condenser exit do not affect the performance of the simple OTEC power cycle. Turbine efficiency and heat exchanger size influence greatly the performance of the Rankine cycle. Finally, it was shown that closed OTEC power plants can practically generate electricity when the difference in warm and cold sea water inlet temperatures is greater than $20^{\circ}C$.
Journal of the Korean Society of Groundwater Environment
/
v.4
no.2
/
pp.73-77
/
1997
Temperature log is an effective method for evaluating the thermal situation and ground water flow path within boreholes. When pumping is proceeding, the continuous temperature logs in a neighboring holt are very helpful to assess connectivity between holes. Mean geothermal gradient is calculated as 26.6$^{\circ}C$/km from 400 bottom hole temperatures, their depths, and the annual mean temperature at each location. Various examples of temperature logs in crystalline rocks are described: first examples show linear increases in homogeneous granitic rocks. Another one illustrates that isolated aquifers have connected each other after a borehole is completed. Slopes of temperature gradient indicate ground water inlet and/or outflow within a borehole. The other log concludes that thermal response in observation borehole induced by pumping is related to the location of interconnected fractures.
Journal of Advanced Marine Engineering and Technology
/
v.28
no.1
/
pp.39-45
/
2004
The commercial viability of heat exchanger is mainly dependent on their long-term fouling characteristics because the fouling increases the pressure loss and degrades the thermal Performance of a heat exchanger. An experimental study was performed to investigate the characteristics of fluid flow and heat transfer in a fluidized bed heat exchanger with circulating various solid particles. The Present work showed that the flow velocity range for Possible collision between the tube wall and the particles was higher with heavier density solid particles. in audition. the solid particle periodically hitting the tube wall broke the thermal boundary laver. and increased the rate of heat transfer.
Korean Journal of Air-Conditioning and Refrigeration Engineering
/
v.14
no.1
/
pp.46-54
/
2002
To investigate the design effects of a heat exchanger on a tube type, a tube circuit and a fin pitch, an experimental study on the heat transfer characteristics of finned- tube evaporators was performed. The refrigerant was R-22. A refrigerant loop was established to measure the heat transfer rate, the air heat transfer coefficient. The experimental results showed that the heat transfer characteristics of the evaporators were affected by the design parameters. And the heat transfer rate of the slit fin was better about 25%, compared to those of the louver fin. In the present experimental range, the heat transfer performance with the straight tube circuit was more remarkable than that of the zigzag tube circuit, as seen from temperature variations of the evaporator exit. $\jmath$-factor on the tube type, the tube circuit and the fin pinch decreased, as increasing Reynolds number.
Transactions of the Korean hydrogen and new energy society
/
v.32
no.1
/
pp.63-67
/
2021
Accurate measurements of the heat transfer coefficients of concentric annular space for the test section is important to measure the tube-side heat transfer coefficients of working fluids. This paper presents the annular side heat transfer coefficients of concentric annuli with variation of tube diameter ratios using Wilson plot method. The test facility has a straight, horizontal test section with an active length of 3.0 m. Inner/outer diameters of test tubes are 7.0/7.5 and 8.0/8.56 mm, respectively. An outer diameter of annulus side is 16.0 mm. The test results show that convective heat transfer coefficients in annuli increase with annular diameter ratio. The correlations for convective heat transfer coefficients in annuli are also developed.
Korean Journal of Air-Conditioning and Refrigeration Engineering
/
v.26
no.9
/
pp.401-408
/
2014
This paper proposes an optimum operation method for open type ground heat exchangers. A series of TRTs and artificial heating/cooling operations were carried out while monitoring temperature in the hole of SCW. The ground temperature naturally increases with depth, but a switch between the cooling/heating mode results in a change in the distribution of ground temperature. The effect of the mode change was evaluated by performing LMTD and COMSOL multiphysics analysis for a reduced model with the depth of 150 m. As a result, in the cooling mode, the upstream operation is more efficient than the downstream operation and reduces EWT by $2.26^{\circ}C$. On the other hand, in the heating mode, the downstream operation is advantageous over the upstream operation and increases EWT by $3.19^{\circ}C$. The merit of the optimum operation will be enhanced for the typical dimension of SCW with a depth of 400~500 m. In the future, an open type ground heat exchanger system adopting the optimum operation with variation in the ground temperature will be used in practice.
Journal of Advanced Marine Engineering and Technology
/
v.36
no.8
/
pp.1016-1023
/
2012
Because heat exchanger consists of many circular tubes, the analysis of local heat transfer and pressure drop at the surrounding of circular tubes, performance and calculation of size, economics play important roles in design. In this study, This study conducted experiment and analysis in order to observe convective heat transfer coefficient LMTD (logarithm mean temperature difference) and pressure losses according to water temperature and air flow rate using a cross flow heat exchanger of staggered arrangement. This heat exchanger was composed of staggered arrangement for five rows and seven columns of tube banks, and the condition of experiment and analysis are $40{\sim}65^{\circ}C$ of water temperature and $5.0{\sim}12.3m^3/s$ of air flow rate. As a result of it, since air density decreases as water temperature and flow rate increases, Reynolds number decreases with characteristics of low flow velocity but mean heat transfer coefficient increases with air flow rate increase, heat transfer performance has been improved and pressure losses decreased. And since heat transfer rate shows about 8~12% and pressure drop around 0.01~7.5% error as the analysis result, the feasibility of this study could be evaluated.
Journal of Advanced Marine Engineering and Technology
/
v.38
no.9
/
pp.1027-1031
/
2014
Free cooling system is used to reduce energy consumption of cooling system. Free cooling system is consisted of cooling group and dry-cooler in which heat exchange of chilled water and out air is conducted. Although this system has an excellent energy saving effect in place having cooling load regularly, data or material of design for free cooling system is lacked. In this study, characteristics analysis of free cooling system is conducted through software HYSYS with changing some facts. The main result is following as : Dry-cooler capacity is influenced by out air temperature, required chilled water temperature and LMTD(Logarithmic Mean Temperature Difference) of heat exchanger. As out air temperature is more low, dry-cooler capacity become increased. in addition, as required chilled water temperature is more high and LMTD is more low, the out air temperature range is widened for using dry-cooler. If out air temperature is below $0^{\circ}C$, antifreeze need to be used because freeze and burst can be occurred. In case of South Korea, antifreeze of 34% of ethylene glycol concentration is proper. When compressor load of R22, R134a and R407C is compared, considering environmental regulation and energy consumption, R134a is best working fluid.
Proceedings of the Korea Water Resources Association Conference
/
2007.05a
/
pp.698-701
/
2007
지하수 개발가능량 산정을 위한 함양량의 평가는 수문계의 물리적인 형태나 함수층의 수리성 분석 및 수직인 지질분포를 파악하여 어떤 조건하에서 물이 유입 유출되는가를 파악한 후에만 가능하다. 또한 지하수계의 물리적인 형태를 이해함으로써 조사지역의 지표수계나 지하수계의 양계를 통해서 흐르는 물의 양을 결정짓는 물수지 분석이 수행되어야 한다. 이에 따라 강수량, 증발산량, 지하수 유출량, 지표유출량 그리고 하천유출량 등을 수문학적으로 고려해야만 한다. 본 연구는 지표수-지하수 결합모형을 도입하여 분포형 지하수 함양량의 시공간적인 변동성을 파악하는 데 그 목적이 있다. 이를 위해 지표수-지하수 결합모형인 SWAT-K모형을 미호천 유역에 적용하였으며, 지표수의 총유출량과 지하수위의 공간분포자료를 이용하여 검정과 검증을 수행하였다. 전체유역에 대한 연평균 함양량은 수문총량의 약 19%인 것으로 나타났다. 1999년${\sim}$2004년까지의 소유역별 연간 함양량 결과를 월별로 나타냈으며, HRU(Hydrologic Response Unit)별 함양량의 공간분포를 통해 월별, 계절별 특성을 살펴볼 수 있었다. 소유역 모두 강수가 집중하는 7-9월에 걸쳐 많은 함양이 이루어지며 $1{\sim}3$월에는 상대적으로 함양이 적은 것을 볼 수 있다. 월함양량의 경우 최대 약200mm범위내에서 유역의 토지이용 및 토양특성, 경사등에 따라 매우 비균질하게 분포하는 것을 확인할 수 있었다. 이와같은 함양량의 시공간적 불균일성으로 인해 지하수 관리방안은 소유역별 함양특성을 반영해야 할 것으로 판단된다.의 종분산지수가 일반적인 자연대수층에 비해 9.1배 정도 높다는 것을 의미한다. 이는 시험대수층의 투수성이 매우 높아 염소이온의 용질이송이 매우 빠르게 발생되었기 때문이다. 본 연구에서 추정된 종분산지수를 Gelhar et al.(1992)의 연구 결과와 비교 분석한 결과에서도 시험규모에 비해 매우 높은 수리분산이 발생된 것으로 나타났다. 그리고 염소이온의 확산면적을 추정하기 위해, 수렴흐름 추적자시험에 의한 종분산지수와 시험대수층의 평균선형유속을 이용하여 종분산계수를 구하였다. 현장에서 수행된 양수시험에 의한 평균선형유속 22.44 m/day와 평균 종분산지수 0.4155 m를 적용하여 산정된 종분산계수는 $9.32\;m^2/day$이었다. 따라서, 시험부지 내 충적층에서 일정한 양수율$(2,500\;m^3/day)$로 지하수를 개발할 시에 양수정 주변지역으로 유입되는 염소이온의 확산면적은 1일 $9.32\;m^2$ 정도일 것으로 나타났다.적인 $OH{\cdot}$ 의 생성은 ascorbate가 조직손상에 관여할 가능성을 시사하였다.었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin
The purpose of this study is to investigate experimentally the heat transfer characteristics of combustion gas or a mixture fuel of LFG and LNG as compared LFG, LNG A Pilot combustion system is constructed. Tube bundle type heat exchangers with vertical and horizontal baffles are used, and the experiment is carried out for different operating conditions, the heating value, the concentration of methane (44.5%, 54.5%). The results show that the Nusselt number of LNG is higher than that of LFG at the same Reynolds number, and in case LFG, the Nusselt number of the mixture of LFG and LNG is larger than that of LFG alone. Therefore, heat transfer is improved by using LFG that is added to LNG pertinently, if and instability of LFG supply will be relaxed.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.