• Title/Summary/Keyword: 대수제어

Search Result 132, Processing Time 0.031 seconds

Valve Openings and Minimum Pump Head for Precise Operation of Multiple Groundwater Injection Wells (군정의 주입량의 정밀 제어를 위한 유량조절밸브의 개도 및 최소 펌프 소요양정)

  • Park, Namsik;Jang, Chi Woong;Cho, Kwangwoo
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.10
    • /
    • pp.869-877
    • /
    • 2015
  • Freshwater may be injected into aquifers to combat sea water intrusion in groundwater or to store water for later retrieval. For these cases to achieve the desired goal groundwater modeling is commonly used to determine locations and rates of injection wells. When these wells are connected to a pipe network, a flow control valve is installed for each well to regulate the injection rate. When a valve opening is modified, pressure changes in the entire pipe network and thereby changes flow rates in other wells. Therefore, desired valve openings must be determined for all injection wells. The pipe flow analysis allows estimation of the minimum pump power in addition to valve openings. Methods are developed to identify valve openings for multiple wells and the minimum pump power. The methodology developed in this work can contribute to precise operation of multiple injection wells.

Design and Implementation of On-board Computers for KAISTSAT-4 (과학위성 1호 탑재 컴퓨터의 설계 및 구현)

  • 곽성우;류상문;박홍영;오대수;유관호;최병재;김병국
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.105-111
    • /
    • 2003
  • Qualification Model of On-board Computer (OBC) for KAISTSAT-4 was developed. The OBC of KAISTASAT-4 has some improved features compared with that of KAISTSAT-3: To reduce weight and size of OBC many logics are implemented by FPGAs, and a network controller is included in OBC to access the satellite network with high speed. Also, the developed OBC has an improved tolerance against SEUs and faults. The OBC was fully tested under simulated space environment with no errors.

A Study for Considering PMU based Online Transient Stability Assessment (PMU 기반 실시간 과도안정도 판정을 위한 고려사항 검토)

  • Seo, Sang-Soo;Kim, Dong-Joon;Kim, Seog-Joo;Moon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.218-219
    • /
    • 2011
  • 한전계통에서는 대규모 발전단지 인출 송전선로 고장 시발전기 과도 안정도 향상을 위한 발전기 제어 대책을 수립하여 운영하고 있다. 이러한 대책을 SPS(Special Protection System)이라고 한다. SPS는 인출 송전선로 고장정지에 따른 과도안정도 평가를 오프라인을 통하여 사전에 모의 분석하여 수립된다. 그러나 대상 계통은 보수적 운영을 위해 가장 가혹한 조건을 선정하여 검토한다. 그러나 차단 대수는 검토 대상 계통에 따라 달라질 수 있다. 그래서 필요한 기술이 실시간과도안정도 평가 기술이다. 본 논문에서는 PMU기반의 실시간 과도 안정도 평가시 고려해야할 사항에 대하여 검토하였다.

  • PDF

The energy-saving effect by controlling the number of operating chillers in university facility (대학시설에 대한 열원기기 대수 운전 제어의 에너지 절약 효과)

  • Lee, Je-Hyeon;Akashi, Yasunori;Kum, Jong-Soo;Kim, Dong-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1043-1048
    • /
    • 2009
  • This paper proposes the new operation control method that let heat source system stop and circulate only hot water at low load, and verified the introduction effect. At first, we constructed simulation model of heat source system and examined the proposing method by using simulation model. At last, we examined the introduction effect of proposing method with actual building. As a result, the primary energy consumption of heat source system was reduced by about 13%.

  • PDF

The Design of Middleware Components for Updata of Distributed Spatial Databases (분산된 공간 데이터베이스의 변경을 위한 미들웨어 컴포넌트의 설계)

  • 정민규;조대수;홍봉희
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.04b
    • /
    • pp.9-11
    • /
    • 2000
  • 본 논문에서는 공간 데이터가 여러 서버에 분산 저장되어 있을 때, 여러 클라이언트에서 동시에 변경 작업을 수행하기 위한 미들웨어 컴포넌트를 설계한다. OpenGIS 구현 명세에는 변경을 위한 미들웨어 인터페이스가 정의되어 있지 않다. OLE DB 데이터 제공자의 변경 인터페이스 사용을 고려 할 수 있으나, 공간 관련성을 가지는 공간 객체의 특징을 반영하고 협동 작업을 통한 동시성 지원을 위해서는 새로운 인터페이스의 설계가 필요하다. 왜냐하면, 기존의 프로토콜을 이용한 인터페이스 구현으로는 클라이언트가 미들웨어를 통해서 분산된 공간 데이터에 대한 변경 작업 수행이 어렵기 때문이다. 본 논문은 분산된 공간 데이터 변경을 위한 인터페이스를 가진 서비스 제공가작 미들웨어를 통한 분산 공간 데이터 변경 프로토콜을 설계하는 것을 목적으로 한다. 즉, 분산된 공간 데이터의 확장 잠금 기법을 통한 일관성 제어와 협동 변경 트랜잭션에 대한 인터페이스를 정의하고, 분산 환경을 고려한 변경 프로토콜을 설계한다.

  • PDF

Hysteresis Reduction in piezoelectric actuator by a charge control method (전하 제어법을 이용한 압전 액추에이터의 이력저감)

  • Jeong Soonjong;Lee Daesu;Song Jaesung;Hong Younpyo;Kang Eungu;Choi Wonjong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.35-39
    • /
    • 2005
  • This paper presents a method to reduce hysteresis in multilayer ceramic actuator by connecting the actuator with a capacitor in a series circuit. The change in hysteresis with respect to the capacitor was examined. $0.2Pb(Mg_{1/3}Nb_{2/3})O_3-0.8Pb(Zr_{0.475}Ti_{0.525})O_3$ ceramic material was used as a piezoelectric material for the actuator. Displacement of the actuator was measured in a capacitive gap sensor measuring system. In case of inserting a capacitor in a total circuit, hysteresis became dramatically decreased, and then finally the hysteresis value can be reduced below $0.2\%$. It was found in this present study that reducing the hysteresis in the actuator is dependent upon the characteristics of the capacitor in total circuit and also operating frequency.

  • PDF

컨테이너터미널 계획을 위한 시뮬레이션 통합관리시스템의 설계

  • 배종욱;양창호;김영훈;김갑환;윤원영
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.05a
    • /
    • pp.49-53
    • /
    • 2001
  • 지금까지 컨테이너터미널을 계획하면서 시뮬레이션을 이용하여 소요자원의 규모나 생산성 등을 분석하려는 연구는 많이 진행되어왔다. 그렇지만 컨테이너터미널의 구성 요소에 대한 전제 조건이 부족한 경우에 도입 가능한 다양한 컨테이너 취급 시스템과 그에 관련된 배치안 및 운영 알고리즘의 조합으로 구성되는 모든 대안들을 시뮬레이션하여 비교 평가하기 위해서는 많은 비용과 시간이 필요하다. 따라서 본 연구의 목적은 상세 분석이 필요한 대상을 선정하기 위해 개발 조건을 고려한 컨테이너터미널의 적정 처리능력, 대안별 시설 규모 및 위치 그리고 하역 장비의 종류 및 운영대수 등을 대략적으로 계획하고 시뮬레이션 분석과 운영정보가 이에 체계적으로 연결되어 효율적인 의사결정을 할 수 있게 정보와 흐름을 통합 관리하는 시스템을 설계하는 것이다. 통합관리시스템은 수행 역할에 따라 프로젝트 관리, 운영정보 관리, 능력계획, 배치계획 그리고 시뮬레이션의 모듈들로 구성된다. 본 논문에서는 각 구성모듈의 기능과 모듈간의 입출력 정보를 정의하였고 시뮬레이션에서 필요한 주요 객체 및 제어 흐름을 설계하기 위해 개체지향방법론의 표준인 UML을 이용하였다.

  • PDF

Algebraic Delay Metric Using Reduced Models of RC Class Interconnects (RC-class 연결선의 축소모형을 이용한 대수적지 연시간 계산법)

  • 김승용;김기영;김석윤
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.193-193
    • /
    • 2003
  • This Paper analyses several model-order reduction methods and then proposes an improved n model and a new delay calculation method to be used in analyzing RC-class interconnects, which does not involve moment calculation processes. The proposed delay calculation method has been derived by combining the unproved $\pi$ model, the concept of effective capacitance and Elmore delay. This method has an advantage in that it can be applied in the calculation of end-to-end delay as well as incremental delay.

A Study on Efficiency of Privacy-preserving Search in Cloud Storage using SGX (SGX를 활용한 클라우드 환경에서의 프라이버시 보존 데이터 검색 효율성에 대한 고찰)

  • Koo, Dongyoung;Hur, Junbeom
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.380-382
    • /
    • 2020
  • 네트워크에 존재하는 저장 공간을 필요에 따라 유연하게 대여하여 사용할 수 있는 클라우드 스토리지 서비스는 데이터의 일관성 유지, 저렴한 유지관리 비용 등 여러 장점에 힘입어 널리 활용되고 있다. 하지만 클라우드 시스템은 데이터 소유자에 의한 관리가 이루어지지 않으므로 민감한 데이터의 노출에 의한 피해 또한 다수 발생하고 있는데, 이를 해결하기 위하여 암호화 등을 통한 프라이버시 보존을 위한 연구가 꾸준히 진행되고 있다. 본 연구에서는 프라이버시가 보존된 상태에서 클라우드에 저장된 데이터를 검색함에 있어, 대수적 난제에 근거를 둔 접근 제어 기능을 내포한 소프트웨어 기반의 검색 가능한 암호화 (searchable encryption) 기법과 최근 많은 관심을 받고 있는 하드웨어 기반 클라우드 데이터 검색의 효율성 및 기능에 대한 비교 분석을 수행한다. 이를 통하여 하드웨어 기반 기법의 활용을 통한 성능 향상 가능성을 확인하고 잠재적 보안 위협을 검토한다.

Effects of Fish and Bacterium on the Morphological and Growth of Cyanobacterium Microcystis aeruginosa (박테리아와 어류가 유해조류 Microcystis aeruginosa의 성장 및 형태변화에 미치는 영향)

  • Kim, Bo-Ra;Han, Myung-Soo;Kim, Baik-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.420-428
    • /
    • 2005
  • Effects of three biological control agents such as Xanthobacter autotrophycus, Tanichthys albonubes and Oryzias latipes on the morphology and growth of cyanobacterium Microcystis aeruginosa were studied. The experiments were consisted of six treatments of living organism (LO) and culture filtered water of three organisms (CFW). Three LOs effectively decreased the density of M. aeruginosa, and then cyanobacteria hardy showed in the microscopic field after 5 days of cultivation. All LO and CFW agents induced the colonial formation of cyanobacterium M. aeruginosa, although there were little differences in colony formation according to the kinds, density and type of treatment. In particular, the higher density treatment of fish CFW induced effectively the colony formation of cyanobacteria, compared to the bacterial LO and CFW. Thus, the application of bio agents to control the cyanobacterial bloom is needed to the further study to diminish the adverse effects such as the enhancement of colony formation towards on the new bloom against the aquatic ecosystem.