• Title/Summary/Keyword: 대비검사

Search Result 384, Processing Time 0.03 seconds

Posttransplant Lymphoproliferative Disorder in Pediatric Liver Transplantation: Samsung Medical Center Experience (소아 간이식에서 Posttansplant Lymphoproliferative Disorder (PTLD): 삼성서울병원의 경험)

  • Choe, Yon-Ho;Lee, Suk-Koo;Seo, Jeong-Meen;Joh, Jae-Won;Kim, Sung-Joo;Lee, Kwang-Woong;Park, Je-Hoon;Ko, Young-Hye;Kwon, Ki-Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.1
    • /
    • pp.39-46
    • /
    • 2003
  • Purpose: In a retrospective study for the pediatric patients who underwent liver transplantation in the past 6 years at Samsung Medical Center, the clinical features of 5 patients with posttransplant lymphoproliferative disorder (PTLD) were analyzed. Methods: Between June 1996 and June 2002, 41 pediatric patients underwent liver transplantation. Seven of them died in the postoperative period. Thirty-five including one patient who died of PTLD were finally reviewed. Patients were divided into two groups: high risk group, EBV naive recipients of EBV-positive grafts; low risk group, the patients other than those in high risk group. The authors reviewed age at operation, immunosuppressive agent, postoperative duration until diagnosis, postoperative duration until EBV seroconversion, presence of treatment against rejection, and presenting symptoms of PTLD. Results: Five of 41 patients (12.2%) developed PTLD. All of them belonged to high risk group, and the incidence of PTLD in high risk group was 31.3% (5/16). The mean age at operation was 10.8 months old and the mean duration between operation and diagnosis for PTLD was 9.8 months. Primary EBV infection developed after a median of 6 months after transplantation. One patient was diagnosed as laryngeal and gastrointestinal PTLD and the other four, gastrointestinal PTLD. The following symptoms and signs were seen in the patients: anemia (100%), hypoalbuminemia (100%), fever (80%), diarrhea (80%), gastrointestinal bleeding (80%), and anorexia (60%). Conclusion: PTLD is one of the major complications after pediatric liver transplantation, especially in the group of high-risk recipients. Anemia, hypoalbuminemia, fever, diarrhea and gastrointestinal bleeding were features that are characteristic of PTLD. The common features of PTLD development were: (i) EBV-positive donors placed into EBV naive recipients, (ii) primary EBV infection about 6 months after transplantation, (iii) young age, about 1 year old at operation, and (iv) the requirement for intensive posttransplant immunosuppression.

  • PDF

Effects of fermented Curcuma aromatica Salisb. powder addition levels on antioxidative and sensory characteristics of curry sauce (발효강황가루 첨가 수준이 카레소스의 항산화 및 관능적 특성에 미치는 효과)

  • Ra, Ha Na;Byeon, Yang Soo;Park, Ji Hyun;Kim, Hae Young
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.3
    • /
    • pp.324-330
    • /
    • 2017
  • The aim of this study was to determine quality characteristics of the curry sauce fortified using Curcuma aromatica Salisb. powder with and without fermentation. Here, the sensory, physicochemical, and antioxidant activity characteristics of the fortified curry sauces were measured. The L, b values of the samples containing the fermented C. aromatica Salisb. were significantly higher than those of the control (p<0.05). The total phenol content of the experimental groups was significantly higher than that of the control (p<0.05). There were no significant differences between the control and the sample fortified with fermented C. aromatica Salisb. (FC1) in the acceptance attributes of curry, spiciness and bitterness. Furthermore, the overall acceptance was similar enough to show no differences between the control and FC1. Thus, we can conclude that the curry sauce fortified using the fermented C. aromatica Salisb. by 1% was successfully developed in the competitive HMR market to promote antioxidant activity without decreasing the sensory characteristics.

Analysis of Geolocation Accuracy of Precision Image Processing System developed for CAS-500 (국토관측위성용 정밀영상생성시스템의 위치정확도 분석)

  • Lee, Yoojin;Park, Hyeongjun;Kim, Hye-Sung;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_2
    • /
    • pp.893-906
    • /
    • 2020
  • This paper reports on the analysis of the location accuracy of a precision image generation system manufactured for CAS 500. The planned launch date of the CAS 500 is 2021, and since it has not yet been launched, the analysis was performed using KOMPSAT-3A satellite images having similar specifications to the CAS 500. In this paper, we have checked the geolocation accuracy of initial sensor model, the model point geolocation accuracy of the precise sensor model, the geolocation accuracy of the precise sensor model using the check point, and the geolocation accuracy of the precise orthoimage using 30 images of the Korean Peninsula. In this study, the target geolocation accuracy is to have an RMSE within 2 pixels when an accurate ground control point is secured. As a result, it was confirmed that the geolocation accuracy of the precision sensor model using the checkpoint was about 1.85 pixels in South Korea and about 2.04 pixels in North Korea, and the geolocation accuracy of the precise orthoimage was about 1.15 m in South Korea and about 3.23 m in North Korea. Overall, it was confirmed that the accuracy of North Korea was low compared to that of South Korea, and this was confirmed to have affected the measured accuracy because the GCP (Ground Control Point) quality of the North Korea images was poor compared to that of South Korea. In addition, it was confirmed that the accuracy of the precision orthoimage was slightly lower than that of precision sensor medel, especially in North Korea. It was judged that this occurred from the error of the DTM (Digital Terrain Model) used for orthogonal correction. In addition to the causes suggested by this paper, additional studies should be conducted on factors that may affect the position accuracy.

2DEG Transport Analysis in AlGaAs/GaAs Interface by MONTE-CARLO Method (MONTE-CARLO 방법에 의한 AlGaAs/GaAs 계면의 전자 전달특성 분석)

  • Nam, Seung-Hun;Jung, Hak-Ki;Kim, Bong-Ryul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.94-101
    • /
    • 1989
  • Transport properties of 2DEG at AlGaAs/GaAs interface such as average electron energy, flight distance, each valley occupancy ratio, average electron velocity for various fields are investigated by MONTE-CARLO method. As the electric field increases, more electrons transit drastically from (000) valley to (000) upper valley. This phenomenon shows the nonstationary effect such as velocity overshoot. The duration of the transient decreases from about 1.4 psec for electric field E = 7KV/cm to about 0.7 psec for 12KV/cm. The average electron velocity during transient transport in 2DEG is about 8 times the steady-state velocity for E = 12KV/cm at room temperature. In comparison with bulk GaAs the peak velocity in the 2DEG is higher than that in even pure bulk GaAs at electric field E = 7 KV/cm. On the basis of the fact that the electrons in the 2DEG have larger peak velocity and shorter transient time of velocity than those in the bulk GaAs, it is suggested that the device with 2DEG may obtain higher mobility than that with bulk GaAs.

  • PDF

Frequency of Micronuclei in Lymphocytes Following Gamma and Fast-neutron Irradiations (방사선 조사량에 따른 인체 정상 림파구의 미세핵 발생빈도)

  • Kim Sung-Ho;Cho Chul-Koo;Kim Tae-Hwan;Chung In-Yong;Yoo Seong-Yul;Koh Kyoung-Hwan;Yun Hyong-Geun
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.35-42
    • /
    • 1993
  • The dose response of the number of micronuclei in cytokinesis-blocked (CB) lymphocytes after in vitro irradiation with $\gamma$-rays and neutrons in the 5 dose ranges was studied for a heterogeneous population of 4 donors. One thousand binucleated cells were systematically scored for micronuclei. Measurements performed after irradiation showed a dose-dependent increase in micronuclei (MN) frequency in each of the donors studied. The dose-response curves were analyzed by a linear-quadratic model, frequencies per 1000 CB cells were ($0.31{\pm}0.049$)D+($0.0022{\pm}0.0002)D^2+(13.19{\pm}1.854) (r^2=1.000,\;X^2=0.7074,\;p=0.95$) following $\gamma$ irradiation, and ($0.99{\pm}0.528$)\;D+(0.0093{\pm}0.0047)\;D^2+(13.31{\pm}7.309)\;(r^2=0.996,\;X^2=7.6834,\;p=0.11) following neutrons irradiation (D is irradiation dose in cGy). The relative biological effectiveness (RBE) of neutrons compared with $\gamma$-rays was estimated by best fitting linear-quadratic model. In the micronuclei frequency between 0.05 and 0.8 per cell, the RBE of neutrons was $2.37{\pm}0.17$. Since the MN assay is simple and rapid, it may be a good tool for evaluating the $\gamma$-ray and neutron response.

  • PDF

Determination of the Shelf-life of Pasteurized Korean Rice Wine, Yakju, in Aseptic Packaging (가열 살균 후 무균 포장한 한국 전통 청주의 저장성에 관한 연구)

  • Lee, Cherl-Ho;Kim, Gi-Myung
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.156-163
    • /
    • 1995
  • The practical shelf-life of pasteurized Korean rice wine ‘Yakju’, aseptically packed in Tetra-pak, was determined. The test sample products were stored at $4^{\circ}C,\;20^{\circ}C,\;30^{\circ}C\;and\;35^{\circ}C$ for 19 weeks, and the quality assessment was made at two weeks interval. The quality parameters evaluated were pH, acidity, reducing sugar, absorbance at 370 nm, total and acid producing bacteria, yeast and mold, and sensory quality. No meaningful changes of pH and reducing sugar were noticed during the storage for 19 weeks at temperatures tested. The absorbance at 370 nm increased slightly during storage. The total numbers of microorganisms in the product decreased during storage and a drastical reduction of acid producing bacteria was observed after 6 weeks of storage. Both yeast and mold were not found in the pasteurized products. The sensory quality of stored rice-wine was evaluated by triangle test and scoring test. The panels could distinguish the product stored at $4^{\circ}C$ from other products stored at the higher temperatures for over 6 weeks. The overall acceptance of the product decreased gradually during storage, and the rate constants for the changes were $7.93{\times}10^{-3},\;at\;20^{\circ}C,\;9.69{\times}10^{-3}\;at\;30^{\circ}C\;and\;13.4{\times}10^{-3}\;at\;35^{\circ}C$, respectively. The activation energy estimated by Arrhenius equation was 24,795 kJ/kmol. The estimated shelf-life of Yakju pasteurized and aseptically packed was 24 months at $10^{\circ}C$, 16 months at $25^{\circ}C$ and 14 months at $25^{\circ}C$. The shelf-life of Yakju in Seoul was calculated to be 20 months, based on the monthly average temperature of the city.

  • PDF

Method Development for the Sample Preparation and Quantitative Analysis of Synthetic Colors in Foods (식품 중 식용타르색소의 시료별 전처리방법 확립 및 함량 분석)

  • Park, Sung-Kwan;Lee, Tal-Su;Park, Seung-Kook
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.893-899
    • /
    • 2004
  • Method for sample preparation and quantitative analysis of 19 permitted and non-permitted synthetic colors in foods was developed based on reversed-phase ion-pairing high performance liquid chromatography. For color extraction of samples, deionized water was added, and pH was appropriately adjusted with 1% ammonia water. Any undissolved matters were extracted with 50% ethanol or 70% methanol. Lipid in snacks was first removed using n-hexane with centrifugation, water was added to extract colors, followed by clean-up and concentration using Sep-Pak $C_{18}$ cartridge. Recovery efficiencies at known concentrations of 19 standard food colors spiked into foods were in 90.3-97.9% range far soft drink, 79.2-101.9% for candy, 84.1-103.4% for jelly, 86.4-100.8% for chewing gum, 83.5-103.4% for ice cream, and 78.5-95.6% for snack.

Quality characteristics of fried fish paste with squeezed Aronia melanocarpa juice (아로니아 착즙액 첨가 튀김어묵의 품질특성)

  • Yun, Jae-Ung;Jung, Ko-Eun;Kim, Dong-Hyun;Nam, Ki-Ho;Sim, Kil-Bo;Jang, Mi-Soon
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.13-20
    • /
    • 2017
  • This study was carried out to investigate the quality characteristics of fried fish paste prepared with different amounts of squeezed Aronia melanocarpa juice. Squeezed Aronia melanocarpa juice (AMJ) was incorporated into fish paste at different levels (containing 2, 7, and 12 g of Aronia melanocarpa juice in 2 AMJ, 7 AMJ, and 12 AMJ, respectively) based on the total weight of water. Sugar contents and total acidity increased with increasing AMJ content. With increasing amounts of AMJ in fried fish paste, L value inside and on the surface decreased, a value increased, and b value inside decreased, whereas b value on the surface increased. pH decreased with increasing levels of AMJ. As the result of textural properties, folding test in all samples showed that AA means good flexibility. The strength, hardness, and chewiness of fried fish paste with AMJ increased while cohesiveness was not significantly different. Total polyphenol contents increased with higher levels of AMJ. DPPH radical scavenging activity was significantly higher than those of the control. In the sensory evaluation, fried fish paste containing 7 AMJ received the highest score than both the control and other samples.

Physicochemical and sensory properties of Yakhobak (Cucurbita maxima subsp. maxima) paste under different high pressure heating conditions (가열조건에 따른 약호박(Cucurbita maxima subsp. maxima) 페이스트의 이화학적 관능적 품질특성)

  • Park, Bo-Ram;Choi, Su-Jeong;Kim, Na-Jeong;Han, Gui-Jung;Kim, Ha-Yun
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.44-51
    • /
    • 2017
  • For the production of Yakhobak (Cucurbita maxima subsp. maxima) paste under various heating conditions, we steamed Yakhobak for roughly 20 min, followed by heating under high pressure treatment for 0 min (HHP0), 20 min (HHP20), 40 min (HHP40), and 60 min (HHP60). The physicochemical and sensory characteristics were subsequently investigated. Generally, no significant difference was observed in organic acid content and sensory characteristics score between Yakhobak paste treated with and without high-pressure heating. However, there was a significant difference in color value, soluble solids, and free sugar content. The L value for color of the group HHP0, untreated control Yakhobak paste (no high-pressure heating), decreased as time increased from 20 min to 60 min, with L values of 44.33, 44.25, and 42.86, respectively. The b value for the color of Yakhobak paste also decreased, showing a significant difference. Soluble solids and free sugar (fructose, glucose, sucrose) contents of the high-pressure heat-treated groups HHP20, HHP40, and HHP60 decreased compared with untreated group HHP0. Organic acid composition of Yakhobak paste included citric acid, malic acid, and fumaric acid, and the major organic acid was malic acid. Sensory score of HHP40 was the highest among all experimental groups in terms of overall preference, but there was no significant difference.

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.