Large-Displacement Electromagnetic Actuators with the Meander Springs Partially Exposed to Magnetic Field (부분적으로 자기장에 노출된 굴곡형 스프링을 이용한 대변위 전자기력 구동기)

  • Seo, Dae-Geon;Han, Won;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.481-486
    • /
    • 2012
  • We discuss the design, fabrication, and testing of a large-displacement electromagnetic actuator with the meander springs partially exposed to a magnetic field. We compared two prototypes: a prototype (F) of the conventional actuator with the meander springs fully exposed to a magnetic field and a prototype (P) of the proposed actuator with the meander springs partially exposed to a magnetic field. For a 5 Hz square input current varying from 10.40 mA, P showed an increase of $16.9{\pm}1.2%$ in the amplitude, which was greater than the increase in the case of F. Thus, we experimentally demonstrated the large-displacement actuation performance of the proposed actuator in a small volume and at low currents (below 40 mA). The proposed electromagnetic actuator can be used for low-power and large-displacement manipulation of optical switches and optical choppers.

Muscle-Inspired Serially-Connected Digital Actuators for Low-Voltage, Wide-Range, High-Precision Displacement Control (저전압 대변위 고정도 구동을 위한 근육모사 직렬연결 디지털 구동기)

  • Lee, Jae-Yong;Lee, Won-Chul;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • This paper presents muscle-inspired serial digital actuators, achieving the improvement of the range-to-precision and range-to-voltage performance. We propose a weight-balanced design for the serial actuators with serpentine springs using serial arrangement of digital actuators. We have measured the displacement range, precision, and drive voltage at unit and serial actuation of 1Hz. The serial digital actuators produce a full range displacement of $28.44{\pm}0.02{\mu}m$, accumulating the unit displacement of $2.8{\pm}0.5{\mu}m$ at the operating voltage of $4.47{\pm}0.07V$. In addition, the serial digital actuators having the displacement precision of $37.94{\pm}6.26nm$ do not accumulate the precision of the unit actuators, $36.0{\pm}17.7nm$. We experimentally verify that the serial digital actuators achieve the range-to-squared-voltage ratio of $1.423{\mu}m/V^2$ and the range-to-precision ratio of 749.6.

X-ray 시스템의 구성 및 TSV (Through Silicon Via) 결함 검출을 위한 응용

  • Kim, Myeong-Jin;Kim, Hyeong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.108.1-108.1
    • /
    • 2014
  • 제품의 고성능 사양을 위해 초미소 크기(Nano Size)의 구조를 갖는 제품들이 일상에서 자주 등장한다. 대표 제품은 주변에서 쉽게 접할 수 있는 전자제품의 반도체 칩이다. 반도체 칩 소자 구조는 크기를 줄이는 것 외에도 적층을 통해 소자의 집적도를 높이는 방향으로 진화를 하고 있다. 복잡한 구조로 인해 발생되는 여러 반도체 결함 중에 TSV 결함은 현재 진화하는 반도체 칩의 구조를 대변하는 대표 결함이다. 이 결함을 효율적으로 검출하고 다루기 위해서는 초미소 크기(Nano Size)의 결함을 비파괴적인 방법으로 가시화하고 분석하는 장비가 필요하다. X-ray 시스템은 이러한 요구를 해결하는 훌룡한 한 방법이다. 이 논문에서는 X-ray 시스템의 구성 및 위의 TSV 결함을 검출하고 분석하기 위한 시스템의 특징에 대해 설명을 한다. X-ray 시스템은 크게 X선을 발생시키는 X선튜브와 대상 물체를 투과한 X선을 영상화하는 디텍터, 대상물체의 영상화를 위해 물체를 적절하게 구동시키는 이동장치로 구성되어 있다. 초미소크기(Nano Size)의 결함 검출을 위해서는 X선 튜브, 디텍터, 이동장치에 요구되는 사양의 복잡도, 정밀도는 이러한 시스템의 개발을 어렵게 만든다. 이 논문에서는 이러한 시스템을 개발 시에 시스템 핵심 요소의 특징을 분석한다.

  • PDF