• Title/Summary/Keyword: 대류열전 달계수

Search Result 202, Processing Time 0.022 seconds

Numerical Study on the Cooling Characteristics of a Passive-Type PEMFC Stack (수동공기공급형 고분자 전해질 연료전지 스택에서의 냉각특성에 대한 전산해석 연구)

  • Lee, Jae-Hyuk;Kim, Bo-Sung;Lee, Yong-Taek;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.767-774
    • /
    • 2010
  • In a passive-type PEMFC stack, axial fans operate to supply both oxidant and coolant to cathode side of the stack. It is possible to make a simple system because the passive-type PEMFC stack does not require additional cooling equipment. However, the performance of a cooling system in which water is used as a coolant is better than that of the air-cooling system. To ensure system reliability, it is essential to make cooling system effective by adopting an optimal stack design. In this study, a numerical investigation has been carried out to identify an optimum cooling strategy. Various channel configurations were applied to the test section. The passive-type PEMFC was tested by varying airflow rate distribution at the cathode side and external heat transfer coefficient of the stack. The best cooling performance was achieved when a channel with thick ribs was used, and the overheating at the center of the stack was reduced when a case in which airflow was concentrated at the middle of the stack was used.

FE-Simulation and Measurement of the Residual Stress in Al6061 During T6 Heat Treatment (Al6061-T6 열처리 잔류응력의 유한요소해석 및 측정)

  • Ko, Dae-Hoon;Kim, Tae-Jung;Lim, Hak-Jin;Lee, Jung-Min;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.717-722
    • /
    • 2011
  • The purpose of this study is to predict the residual stress in Al6061 during T6 heat treatment. In this study, the variable residual stress in case of the solid solution($530^{\circ}C$, 2h) and artificial ageing($175^{\circ}C$, 9h) of Al6061 subjected to T6 heat treatment is determined at different ageing times. A heat treatment experiment is conducted to determine the heat transfer coefficient, on the basis of which the residual stress during the T6 heat treatment is predicted. In order to take into account the relaxation of residual stress during artificial ageing, a Zener-Wert-Avrami function is used and elasto-plastic nonlinear analysis is conducted through FE-simulation. Further, the residual stress is measured by using the X-ray diffraction(XRD) method, and the result is compared with the result from the FE-simulation. It is found that the residual stress predicted form the FE-simulation is in good agreement with the residual stress measured by using the XRD method.