• Title/Summary/Keyword: 대동맥 판막치환술

Search Result 123, Processing Time 0.027 seconds

Regression of Left Ventricular Mass after Aortic Valve Replacement in Isolated Aortic Regurgitation (단독 대동맥판막 폐쇄부전 환자에서 대동맥판막 치환술 후 좌심실 질량의 변화)

  • Jung, Tae-Eun;Lee, Dong-Hyup;Lee, Seok-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.614-618
    • /
    • 2010
  • Background: The aim of our study was to assess the extent of regression of left ventricular mass after aortic valve replacement in isolated aortic regurgitation. Material and Method: Retrospective analysis of echocardiographic data was collected preoperative and postoperative 1 year. There were 20 patients (12 males, 8 females, mean age $55.8{\pm}11.8$ years, mean body surface area $1.64{\pm}0.19m^2$) with aortic regurgitation from 2002 through 2007. We studied the change of left ventricular ejection fraction, ventricular septum and left ventricular posterior wall thickness, and left vemtricular muscle index (LVMI). The control group was age matched with normal echocardiographic study results. Patients with combined surgery or infective endocarditis were excluded. Result: Seven cases of tissue valves and thirteen cases of mechanical valve were used. The valve sizes were 21 mm (3 cases), 23 mm (13 cases) and 25 mm (4 cases). The postoperative ($125.5{\pm}42g/m^2$) LVMI has decreased than preoperative LVMI ($212.3{\pm}80g/m^2$, p=0.000) but higher than that of control group ($80.5{\pm}15.9g/m^2$, p=0.000). Postoperative septal wall (systolic/diastolic: $13.5{\pm}3.4mm/17.1{\pm}4.1mm$) and left ventricular posterior wall (systolic/diastolic: $12.9{\pm}3.4mm/16.7{\pm}3.4mm$) thickness were slightly decreased after the valve replacement but was not significantly different than preoperative levels. And postoperative interventricular septal wall and left ventricular posterior wall thickness (systolic/diastolic: $8.6{\pm}1.4mm/12.1{\pm}1.7mm$, systolic/diastolic: $8.4{\pm}1.4mm/13.2{\pm}1.9mm$) were higher than that of the control group (p<0.001). Conclusion: The significant regression of LVMI after aortic valve replacement developed at postoperative one year but the level was higher than control group. The main cause of decreased LVMI is decreased in left ventricular dimension.

Clinical Result of Aortic Valve Replacement (대동맥판막 치환술의 임상성적)

  • 최순호;양현웅;김은규;최종범
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.591-597
    • /
    • 1998
  • Background: The aim of the current study was to analyze the early and intermediate-term performance of aortic valve replacement. Material and Method: Between January 1986 and January 1996, records of 61 consecutive patients who had received aortic valve replacement were reviewed. 38 were male and 23 were female patients, ranging from 10 to 71 years of age(mean: 40.5${\pm}$11.2). Results: The early death rate was 4.9%(3/61). A thorough follow-up rate of 93.1% was accomplished in these 58 patients who left the hospital(mean: 51.5${\pm}$32.0 patient-months) under the assistance of the same operator. Three of these patients who left the hospital died. The late death rate was 5.2%(3/58). Five patients experienced anticoagulant-related hemorrhage(all were minor). Three patients had thromboembolic episodes. There was no clinical evidence of hemolysis and structural failure of valves used. Of those patients who survived, the NYHA functional class improved significantly. Linearized rate were 1.58%/patient-year and 2.0%/patient-year respectively for thromboembolism and anticoagulant-related hemorrhage. The 10 year actuarial survival rate was 83.6%. Conclusion: This early and intermediate-term follow-up suggests that the mechanical valve is a reliable and durable prosthesis with good hemodynamic function and low rate of prosthesis-related complication.

  • PDF

Surgical Treatment for Multivalvular Heart Disease (중복 심장판막 질환의 외과적 치료)

  • Kim, Jin; Jo, Jung-Ku;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.875-882
    • /
    • 1996
  • Multlvalvular heart surgery was performed In 78 cases, in the Department of Thoracic & Cardiovascu far Surgery of Chonbuk national University Hospital from november 1983 to March 1994. There Where 31 men and 47 women. whose ranged from 14 to 63 years. The causes of the valvular lesions were 57 rheumatic origin, 18 degenerative, 1 previous endocarditls, 1 prosthetic valve mal-function. There were 25 double valve replacement with or wit out tricuspid valve repair, i M VR and aortic valve repair, 18 MVR and tricuspid valve repair, 1 MVR and aortic and tricuspid valve repair, 10 AVR and mi- tral valve repair, 1 AVR and tricuspid valve repair, 8 mitral aortic valve repair, 13 mitral and tricuspid valve repair. They were improved mean New York Heart Association functional cldss, from 2.72% 121 Early deaths were 5 cases(6.4%). The cause of death wet'e low cArdiac output syndrome. veritricular tachycardia, massive bleeding and cerebral thromboembolism. All the survivors belonged to New York Heart Association functional class I or ll at discharge. The patients who had had valve replacement operation were medicated with warfarin to maintain the level of 30∼ 50% of normal prothrombin time. During follow-up(93.6%, mean 49.9 months), 2 late deaths were developed. One was due to intracranial hemorrhage and the other congestive heart failure. The pre-operative New York Heart Association Functional class IV was statistically sig ificant operat- ive risk factors(p< 0.05).

  • PDF

Aortic Valvuloplasty Using Triangular Resection lechniolue (설상절제술(triangular resection)을 사용한 대동맥판막 성형술의 단기 성적)

  • 김욱성;정철현;허재학;백만종;이석기;박영관;김종환;장우익;장지민
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.113-117
    • /
    • 2002
  • With an increasing awareness of the limitations of both mechanical prostheses and bioprostheses, aortic valvuloplasty has gained attention as an alternative procedure for aortic valve disease. Material and Method: Eight consecutive patients underwent aortic valvuloplasty caused by leaflet prolapse between June 1799 to June 2000. Mean age of the patients was 18.4$\pm$12.6 year. Four paitents(50%) were male. Six patients had tricuspid valves and ventricular septal defect and two patients had bicuspid valves. The extent of aortic insufficiency was 3.5$\pm$0.5 by preoperative Doppler echocardiography. The technique involved triangular resection of the free edge of the prolapsed leaflet, annular plication at the commissure, and resection of a raphe when present in bicuspid valves. Result: There was no in-hospital mortality or morbidity. Mean follow-up was complete at 11.973.6months. There was no late mortality or morbidity. The amount of the severity of aortic insufficiency, as assessed by echocardiography preoperatively, postoperatively and at late follow-up was 3.5$\pm$0.5, 0.6$\pm$0.5 and 0.8$\pm$0.6, respectively(p value : 0.01). There was one patient with grade 2/4 aortic insufficiency and in the other patients, grade 1/2 or trivial aortic insufficiency were detected with late echocardiograms. Conclusion: Triangular resection in the patients with aortic leaflet prolapse offers a good early clinical result, but long-term follow-up is necessary.

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF

Diagnostic Performance of Cardiac CT and Transthoracic Echocardiography for Detection of Surgically Confirmed Bicuspid Aortic Valve: Effect of Calcium Extent and Valve Subtypes (외과적으로 확진된 이첨 대동맥 판막의 진단을 위한 심장 CT 및 경흉부 심초음파의 진단적 성능: 판막 아형 및 칼슘의 양이 미치는 효과)

  • Jeongju Kim;Sung Mok Kim;Joonghyun Ahn;Jihoon Kim;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1324-1336
    • /
    • 2023
  • Purpose This study aimed to compare the diagnostic performance of cardiac CT and transthoracic echocardiogram (TTE) depending on the degree of valvular calcification and bicuspid aortic valve (BAV) subtype. Materials and Methods This retrospective study included 266 consecutive patients (106 with BAV and 160 with tricuspid aortic valve) who underwent cardiac CT and TTE before aortic valve replacement. Cardiac CT was used to evaluate the morphology of the aortic valve, and a calcium scoring scan was used to quantify valve calcium. The aortic valves were classified into fused and two-sinus types. The diagnostic accuracy of cardiac CT and TTE was calculated using a reference standard for intraoperative inspection. Results CT demonstrated significantly higher sensitivity, negative predictive value, and accuracy than TTE in detecting BAV (p < 0.001, p < 0.001, and p = 0.003, respectively). The TTE sensitivity tended to decrease as valvular calcification increased. The error rate of TTE for CT was 10.9% for the twosinus type of BAV and 28.3% for the fused type (p = 0.044). Conclusion Cardiac CT had a higher diagnostic performance in detecting BAV than TTE and may help diagnose BAV, particularly in patients with severe valvular calcification.

Outcomes of Combined Mitral Valve Repair and Aortic Valve Replacement (대동맥판막 치환술과 동반시행한 승모판막 성형술 결과)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Soo-Cheol;Lim, Cheong;Kim, Wook-Sung;Lee, Young-Tak;Choi, Hyun-Seok;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.463-471
    • /
    • 2003
  • The long-term results of combined mitral valve repair and aortic valve replacement (AVR) have not been well evaluated. This study was performed to investigate the early and long-term results of mitral valve repair with AVR. Material and Method: We retrospectively reviewed 45 patients who underwent mitral valve repair and AVR between September 1990 and April 2002. The average age was 47 years: 28 were men and 17 women. Twelve patients had atrial fibrillation and three had a previous cardiac operation. The mitral valve disease consisted of pure insufficiency (MR) in 34 patients, mitral stenosis (MS) in 3, and mixed lesion in 8. Mitral valve disease was due to rheumatic origin in 24 patients, degenerative in 11, annular dilatation in 8, and ischemia or endocarditis in 2. The functional anatomy of mitral valve was annular dilatation in 31 patients, chordal elongation in 19, leaflet thickening in 19, commissural fusion in 13, chordal fusion in 10, chordal rupture in 6, and so on. Aortic prostheses used included mechanical valve in 32 patients, tissue valve in 12, and pulmonary autograft in one. The techniques of mitral valve repair included annuloplasty in 32 patients and various valvuloplasty of 54 techniques in 29 patients. Total cardiopulmonary bypass and aortic cross clamp time were 204$\pm$62 minute and 153$\pm$57 minutes, respectively. Result: Early death was in one patient due to low output syndrome (2.2%). After follow up of 57$\pm$37 months, late death was in one patient and the actuarial survival at 10 years was 96$\pm$4%. Recurrent MR developed grade II or III in 11 patients and moderate MS in 3. Three patients required reoperation for valve-related complications. The actuarial freedom from recurrent MR, MS, and reoperation were 64$\pm$11%, 86$\pm$8%, and 89$\pm$7% respectively. Conclusion: Combined mitral valve repair with AVR offers good early and long-term survival, and adequate techniques and selection of indication of mitral valve repair, especially in rheumatic disease, are prerequisites for better long-term results.

Abstract Minimally Invasive Aort ic Valve Surgery -A Report of Two Cases (최소 침습성 대동맥 판막 수술 -2례 보고-)

  • 백완기;김현태
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1139-1141
    • /
    • 1997
  • Recently, minimally invasive approach via limited incision becomes one of the rapidly developing strategy in cardiac surgery as it gives less surgical trauma and is more satisfactory to the patients in respect to operative scar although the surgical technique is more demanding. Here, we report two cases of aortic valve replacement via limited transsternal incision. The methodology is described with review of the relevant literature.

  • PDF

Cineradiographic Diagnosis of Mechanical Valve Thrombosis - Two Cases Report - (기계판막혈전의 cineradiographic 진단;2례 보고 `)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • v.25 no.9
    • /
    • pp.921-924
    • /
    • 1992
  • 기계판막의 가장 빈번하고 치명적인 결함이 판막혈전이다. 판막혈정의 적절한 조기 치료를 위해서는 조기진단이 선행되어야만 한다. Cineradiography는 조기에 손쉽고, 빠르게 기계판막의 기능장애를 진단하는 방법으로 사료되며 저자들은 42세된 남자 환자에서 29mm Carbomedics 판막으로 승모판막 치환술을 시행한 1례와 58세된 여자 환자에서 승모판막 및 대동맥판막에 각각 25mm, 19mm Carbomedics 판막으로 치환술 후 각각 18개월, 20개월 후 기계판막 혈전이 발생하여 cineradiography로 손쉽게 진단하여 치료하였으므로 보고하는 바이다.

  • PDF

Acute Mesenteric Ischemia after Aortic Valve Replacement -A case report- (대동맥 판막 치환술 후 발생한 급성 창자간막 허혈 -1예 보고-)

  • Jun, Yang-Bin;Ahn, Young-Chan;Park, Chul-Hyun;Choi, Chang-Hyu;Lee, Jae-Ik;Park, Kook-Yang
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.939-942
    • /
    • 2006
  • Acute mesenteric ischemia after cardiac surgery is a serious complication associated with high mortality. Superior mesenteric artery is most commonly affected artery. Acute obstruction of mesenteric artery generally has an unfavorable prognosis because of late diagnosis. The keys to a successful outcome are early diagnosis and appropriate operative intervention. We successfully treated a patient with acute mesenteric ischemia after aortic valve replacement. Therefore, we report a case with a review of articles.