• Title/Summary/Keyword: 대동맥 치환

Search Result 221, Processing Time 0.034 seconds

국제학술회의 참관기-제6차아시아 심혈관외과학회

  • Lee, Jae-Won
    • The Science & Technology
    • /
    • v.31 no.5 s.348
    • /
    • pp.30-31
    • /
    • 1998
  • 지난2월18일부터 3일간 일본 동경 게이오플라자 호텔에서 아시아의 심혈관 학자들이 참석한 가운데 제6차 아시아 심혈관학회의 학술발표가 열렸다. 대회 첫날엔 서울대 서경필교수가 한국의 심혈관외과 현황에 대한 브리핑을 했고 한국측에서 11개의 논문이 발표되었다. 필자인 울산의대 서울 중앙병원 이재원 교수는 「대동맥 판막 치환후 좌심실근 비후의 변화」라는 논문을 발표해 큰 관심을 모았다.

  • PDF

Valve Replacement in Children (소아심장판막치환술)

  • 김재현;이광숙;윤경찬;유영선;박창권;최세영
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • Background: Thirty children ranging from 3 to 15 years of age underwent cardiac valve replacement at Dongsan Medical Center from 1982 to 1997. Material and Method: There were 16 boys and 14 girls. The mean age was 12.1. The underlying pathological cause for valve replacement was congenital heart disease in 17 children and acquired heart disease in 13. The valve replaced was mitral in 15 children, aortic in 11, tricuspid in 3, and combined aortic and mitral in 1. Twenty-one mechanical and 10 tissue valves were placed: primary mechanical valve have been utilized since 1985. Eight of ten patients with tissue valves have had successful second valve replacements 4 to 11 years after the initial operation. Result: The operative mortality was 6.7%, but mortality was higher among patients less than 5 years of age and patients who had previous cardiac operations. Of the 28 operative survivors, 4 patients were lost to follow-up: the remaining patients were observed for a total of 2091 patient/months(mean 74.7 months, maximum 187 months). There was one late death from dilated cardiomyopathy after mitral valve replacement in 7 year-old patient with atrioventricular septal defect. After the operation, all patients with mechanical valves were placed on a strict anticoagulant regimen with Coumadin. The actuarial survival rate was 96% at the end of the follow-up. No instance of thromboembolism or major bleeding were observed in the survivors. Conclusion: These results indicate that valve replacement can be performed with low mortality in children, and with satisfactory long-term survival.

  • PDF

Comparison of the Neurologic Outcome according to the Method of Proximal Graft Anastomosis at the Aortic Side during Off-pump Coronary Artery Bypass Grafting: The Heartstring Sealing System versus Conventional Manual Anastomosis (무심폐기 관상동맥 우회술에 있어서 이식편의 대동맥부 근위부 문합 방법에 따른 수술 후 신경학적 합병증 발생의 비교: 하트스트링을 이용한 방법 대 고식적인 수기 문합술)

  • Cho, Won-Chul;Kim, Joon-Bum;Kim, Hee-Jung;Kim, Hwan-Wook;Kim, Yun-Seok;Jung, Jae-Seung;Choo, Suk-Jung
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.441-446
    • /
    • 2009
  • Background: Side clamping of ascending aorta during proximal graft anastomosis in coronary bypassing surgery in-creases the risk of direct aortic injury as well as embolization of intimal atheroma. Heartstring proximal sealing system (Guidant Corporation, Santa Clara, Calif), developed to avoid aortic side clamping, may minimize risks of such complications. The aim of the current study is to compare the surgical outcomes of the two proximal anastomosis techniquesi.e., Heartstring system versus aortic side clamping in off pump coronary bypassing' surgery (OPCAB). Material and Method: From January 2003 to August 2008, 499 patients underwent OPCAB. Of them, proximal graft anastomosis was performed using Heartstring system in 182 patients (Group I) and conventional manual anastomosis in 317 patients (Group II). The two groups were compared for postoperative major complications and mortality. Result: Two groups showed similar characteristics in terms of preoperative demographic data, left ventricular ejection fraction, renal function and history of diabetes, hypertension and smoking. Although there was no inter-group difference in the history of cerebral ischemia (p=0.48), preoperative brain magnetic resonance angiography revealed greater incidence of severe carotid artery stenosis (>75% of lumen) in the Group I than in the. Group II (44.5% in the Group I and 30.0% in the Group II, p=0.003). There were no inter-group differences in postoperative mortality (p=0.40) and complications (p=0.47) including neurologic events (3 in the Group land 2 in the Group II, p=0.258). Whereas neurologic events all comprised transient ischemic attacks in the Group I, they comprised multiple embolic strokes in the Group II. One patient in the Group II experienced aortic dissection during proximal anastomosis which resulted in ascending aortic replacement. Conclusion: Although proximal anastomosis using Heartstring system did not show statistically significant benefit over aortic side clamping, the. absence of embolic stroke maybe a definite benefit which may be better defined through further studies over a larger cohort.

Clinical Analysis of Reoperation for Prosthetic Valve Replacement Report of 12 cases (인공판막 치환수술 재수술에 대한 임상적 고찰 -12예보고-)

  • 장진우;이연재
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.390-395
    • /
    • 1997
  • Between May 1986 and May 1996, 269 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 70 cases and mechanical valve was replaced in 232. Of this 12 patients performed reoperations for replacement, and the mean interval between primary valve operation and reoperation was 87.6 months for mitral valve and )7.7 months for aortic valve. There were 10 women and 2 me , agcd from 22 to 68 years(mean 45). A bioprosthetic valve was implanted in 8 cases and a mechanical valve was implanted in 4 cases for initial operation. llidications for reoperation were structural deterioration in 5 cases(42%), valve thrombus in 5 cases(42%) and endocarditis in 2 cases(17%). Operations performed included 3 aortic valve replacements(25%), 9 mitral valve replacements(75%). Wc used mechanical valve in llcases(92%) and tissue valve in 1 case(8%) for reoperation. There were 2 early operative deaths because of valve detachment and of acute respiratory failure. Among ten survivor's, there were no late deaths with follow up of 35.8 months.

  • PDF

Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve (On-X 기계판막을 이용한 판막치환술의 단기성적분석)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.742-748
    • /
    • 2004
  • The On-X valve was recently introduced. It was the aim of this study to assess the safety and feasibility from the data derived from 28 patients who underwent aortic and/or mitral valve replacement with this prosthesis in National Medical Center. Material and Method: From May 1999 and May 2003, a series of 28 consecutive patients who had been implanted with 32 On-X prosthesis were reviewed, The operative procedure comprised of 12 MVR, 10 AVR and 6 DVR. The study followed the guidelines of AATS/STS. Mean follow-up was 27 months (total 04 patient-years). Result: Early ($\leq$30 days) mortality was 7.44% (2/28) and no late mortality occurred in the study. Total actuarial freedom from mortality at 2 years was 92.86$\pm$4.87% for all cases, 100% for MVR, 90$\pm$9.49% for AVR, and 83.3$\pm$1.52% for DVR. Thromboembolic event occurred in 2 MVR patients and that was the only complication; therefore, the linearized incidence of valve related complications was 3.17%/ patient-years for all cases and 6.5%/patient-years for MVR and the actuarial freedom from valve related complications at 2 years was 84.85$\pm$10.75%. Preoperatively, 24 (85.71%) patients were in NYHA functional class III or IV but postoperatively, 25 (89,29%) patients were in NYHA functional class I or II. The levels of hemoglobin, hematocrit, serum LDH, reticulocyte rate and indirect bilirubin were all within normal range at postoperative 3 month. In mitral position, the peak gradient was 6.1$\pm$1.8 mmHg and the mean gradient was 3.0$\pm$0.6 mmHg and EOA were 2.54$\pm$0.56 $m^2$, 2.39$\pm$0.73 $m^2$, 2.34$\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$ at 27 mm, 29 mm, 31 mm, 33 mm respectively. In aortic postion, the peak gradient was 21.1 $\pm$14.12 mmHg and the mean gradient was 12.3$\pm$6.52 mmHg. Conclusion: Since there was no significant difference in the postoperative mortality, valve related complications and echocardiographic hemodynamic data compared to standard bileaflet design and since there was an improvement in the NYHA functional class and normal values of hemolytic indicators, it can be assumed that On-X valve is safe and feasible. However, accumulation of cases and long-term follow-up of this patient group is needed to establish this result.

Ascending Aortic Dissection Late After Aortic Valve Replacement (대동맥 판막 치환술 후 만기에 발생한 상행 대동맥 박리증)

  • 오정훈;이동협;이정철;정태은;이장훈;한승세
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.630-633
    • /
    • 2001
  • Central anticholinergic syndrome is defined as an absolute or relative reduction in cholinergic activity in the central nervous system and has a wide variety of manifestations. It is associated with almost any drug given during anesthesia, except neuromuscular relaxants, and treated with the cholinesterase inhibitor physostigmine. The diagnosis of central anticholinergic syndrome is often made when symptoms resolve promptly after the administration of physostigmine. We present a case of a central anticholinergic syndrome diagnosed by treatment with physostigmine, in a patient who received closure of patent foramen ovale associated with stroke.

  • PDF

Cineradiographic Diagnosis of Mechanical Valve Thrombosis - Two Cases Report - (기계판막혈전의 cineradiographic 진단;2례 보고 `)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • v.25 no.9
    • /
    • pp.921-924
    • /
    • 1992
  • 기계판막의 가장 빈번하고 치명적인 결함이 판막혈전이다. 판막혈정의 적절한 조기 치료를 위해서는 조기진단이 선행되어야만 한다. Cineradiography는 조기에 손쉽고, 빠르게 기계판막의 기능장애를 진단하는 방법으로 사료되며 저자들은 42세된 남자 환자에서 29mm Carbomedics 판막으로 승모판막 치환술을 시행한 1례와 58세된 여자 환자에서 승모판막 및 대동맥판막에 각각 25mm, 19mm Carbomedics 판막으로 치환술 후 각각 18개월, 20개월 후 기계판막 혈전이 발생하여 cineradiography로 손쉽게 진단하여 치료하였으므로 보고하는 바이다.

  • PDF

Operative Treatment of Mitral Valve Regurgitation due to Papillary Muscle Rupture from Acute Myocardial Infarction Under ECMO -A case report- (급성심근경색 후 발생한 유두근 파열로 인한 승모판 판막 폐쇄부전의 체외막 산소화 장치하 승모판막 치환술 - 1예 보고 -)

  • Joo, Seok;Choo, Suk-Jung;Jung, Sung-Ho;Je, Hyoung-Gon
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.172-175
    • /
    • 2010
  • A 61-year-old man presented with chest pain and ST elevation, and he underwent coronary angiography under the impression of acute myocardial infarction. Coronary intervention under intra-aortic balloon pumping was necessary due to his hemodynamic instability from the acute total occlusion of a large obtuse marginal branch. In spite of successful intervention, the cardiogenic shock persisted, and so extracoporeal membranous oxygenation was performed to treat this. Afterwards, the cardiogenic shock still persisted, and the auscultatory and echocardiographic findings revealed severe acute mitral valve regurgitation. Emergency mitral valve replacement was then performed. The ECMO and IABP were removed on the $2^{nd}$ postoperative day. The patient was discharged on the $48^{th}$ postoperative day.

Research of PPI prediction model based on POST-TAVR ECG (POST-TAVR ECG 기반의 PPI 예측 모델 연구)

  • InSeo Song;SeMo Yang;KangYoon Lee
    • Journal of Internet Computing and Services
    • /
    • v.25 no.2
    • /
    • pp.29-38
    • /
    • 2024
  • After Transcatheter Aortic Valve Replacement (TAVR), comprehensive management of complications, including the need for Permanent Pacemaker Implantation (PPI), is crucial, increasing the demand for accurate prediction models. Departing from traditional image-based methods, this study developed an optimal PPI prediction model based on ECG data using the XGBoost algorithm. Focusing on ECG signals like DeltaPR and DeltaQRS as key indicators, the model effectively identifies the correlation between conduction disorders and PPI needs, achieving superior performance with an AUC of 0.91. Validated using data from two hospitals, it demonstrated a high similarity rate of 95.28% in predicting PPI from ECG characteristics. This confirms the model's effective applicability across diverse hospital data, establishing a significant advancement in the development of reliable and practical PPI prediction models with reduced dependence on human intervention and costly medical imaging.

Long-term Results after 1,144 CarboMedics Mechanical Valve Implantation (CarboMedics 기계판막을 이용한 1,144예 판막치환술의 장기 성적)

  • Kang, Chang-Hyun;Kim, Kyung-Hwan;Kim, Ki-Boong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.559-569
    • /
    • 2004
  • The CarboMedics mechanical valve has been reported to show acceptable valve-related complication rates. The aim of this study is to evaluate our clinical experience with the CarboMedics valve. Material and Method: Between August 1988 and September 1999, we implanted 1,144 CarboMedics valves in 850 patients (aortic 179; mitral 385; double-valve 234; tricuspid 52). The mean age was 44.5 $\pm$ 12.5 years. Follow-up was completed in 95.2% and median follow-up period was 7.9 years (6753 patient-years). Result: The overall hospital mortality rate was 3.4% and the mortality rate for each group was 1.7% for aortic group, 2.6% for mitral group, 4.7% for double-valve group, and 9.6% for tricuspid group, Tricuspid group showed significantly higher mortality rate than aortic and mitral group (p〈0.05). The actuarial survival at 10 years was 87.1 $\pm$ 2.6%, 88.9 $\pm$ 1.7%, 82.4 $\pm$ 2.9%, and 77.5 $\pm$ 7.0% for aortic, mitral, double, and tricuspid valve group, respectively. Age and tricuspid valve replacement were significant risk factors for long-term survival in multivariate analysis (p 〈 0.05). Freedom from valve thrombosis at 10 years was 99.4 $\pm$ 0.6%, 98.2 $\pm$ 0.8%, 99.2 $\pm$ 0.8%, and 87.6 $\pm$ 0.5% for aortic, mitral, double and tricuspid valve group. Tricuspid valve group showed significantly higher rate of valve thrombosis (p 〈 0.05). Conclusion: Long-term results of our experience demonstrated that CarboMedics valve showed acceptable incidence of valve-related complications. However, tricuspid valve replacement showed higher rate of early mortality and valve thrombosis than other valve replacement groups.