• Title/Summary/Keyword: 대동맥류 박리

Search Result 47, Processing Time 0.019 seconds

Single Stage Replacement of Entire Thoracic Aorta for Chronic Aortic Dissection (만성 대동맥 박리 환자에서 전 흉부 대동맥 동시 치환)

  • 최진호;박계현;전태국;이영탁;박표원
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.865-869
    • /
    • 2001
  • Operations for extensive aortic aneurysm are generally performed as staged operations with or without elephant trunk technique. However, we must consider single stage replacement in cases that are unsuitable for elephant trunk technique. We report a case of successful sing1e stage replacement of the entire thoracic aorta from the aortic valve to the level of diaphragm. The patient was a 35-year-old male who had Marfanoid features and had previously undergone replacement of the ascending aorta for aortic dissection. He recovered without neurologic complication and was discharged on 29th day after the operation. .

  • PDF

Clinical Study of Surgical Treatment of Aortic Aneurysm (대동맥류의 수술적 치료에 관한 임상적 연구)

  • Ryu, Ji-Yun;Jeon, Hong-Ju;Jo, Gwang-Hyeon
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.300-307
    • /
    • 1997
  • We have experienced 25 cases of aortic aneurysm from October 1987 to January 1996. Patients ranged in age from 26yrs to 73yrs(mean age 52. Syrs). There were 13 males and 12 females. Eighteen cases were thoracic aneurysm and seven were abdom nal aneurysm. The cause of aneurysm were dissecting in 16cases aneurysms and non-dissecting in 9 cases. Risk factors of aortic aneurysm were hypertension, hypercholesterolemia, Marfan's syndrome. In thoracic aneurysm patients, 1'S cases of dissecting aneurysm underwent aneurysmectomy and replacement of vessel interposition graft with or without coronary artery implantation on the graft. 6 cases of non-dissecting aneurysm underwent operation with same policy as dissecting aneurysm. In 7 case of abdominal aneurysm,all patients underwent aneurysmectomy and graft interposition with straight i)r Y graft. Thcre were 5 postoperative death(mortality 20%). Several cases of complications were improved with proper managements. All survivors showed improvement in clinical symptom and sign and discharged without specific complications.

  • PDF

Hand-assisted Laparoscopic Abdominal Aortic Aneurysm Repair Through a 6 cm Incision (6 cm 절개선을 통한 수기 보조 복강경 복부 대동맥류의 수술)

  • Choi, Hyung-Yoon;Song, Suk-Won;Yi, Gi-Jong
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.645-648
    • /
    • 2009
  • We performed hand-assisted laparoscopic surgery for a 67-year-old male with a 5.6 cm sized abdominal aortic aneurysm. To the best of our knowledge, this is the first report in Korea. After an initial hand dissection of the abdominal aorta under laparoscopy, we performed proximal anastomosis and distal abdominal. aorta suture ligation through a 6 cm abdominal incision. Distal anastomosis was done at the bilateral common femoral arteries. He resumed his oral intake 6 hours after the surgery and discharged at the $4^{th}$ postoperative day.

Management for the Newly-Onset Aneurysmal Dilation of the Distal Aorta after an Endovascular Stent Graft Procedure for the Patient with Acute Aortic Dissection Type IIIb (급성 하행대동맥 박리증에서 스텐트-그라프트 삽입 후 새로이 발생한 원위부 대동맥류에 대한 인조혈관 대치술 치험 1예)

  • 이길수;방정희;조광조;성시찬;우종수
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.427-430
    • /
    • 2003
  • The surgical managements for the complicated aortic disease is still one of most challenging fields for the cardiac surgeons. The endovascular stent graft procedure has been tried recently to avoid serious complications caused by traditional graft replacement technique. However, indications for the procedures or management methods for the complications have not been clearly elucidated so far. We report a case of successful management for the newly-onset aneurysmal dilation of the distal aorta after an endovascular stent graft procedure in a patient with acute aortic dissection type IIIB.

Aortic Arch Debranching and Antegrade Stent Graft Placement in an Expanding Distal Dissecting Aneurysm after Repair of an Acute Type I Aortic Dissection (Type I 급성 대동맥 박리 수술 후 진행하는 원위부 박리성 동맥류에 대한 대동맥궁 탈분지술과 전향적 대동맥궁 스텐트 그라프트의 설치)

  • Baek, Wan-Ki;Kim, Young-Sam;Lim, Hyun-Kyoung;Yoon, Yang-Han;Kim, Joung-Taek;Kim, Kwang-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.729-733
    • /
    • 2010
  • Endovascular treatment of the aortic aneurysm with a stent graft is rapidly evolving. We describe here a case of hybrid TEVAR (thoracic endovascular aortic repair) in which the stent grafts were placed in the aortic arch after debranching of the arch vessels. The patient had undergone ascending aorta replacement for acute type I aortic dissection 2.5 years earlier. The aneurysmal change of the distal dissection progressed with time. A provisional bypass surgery from the ascending aorta to the innominate artery and left carotid artery was performed and then stent grafts were inserted via an antegrade route that covered the whole aortic arch and proximal descending thoracic aorta.

One-Stage Ascending, Arch. and Descending Thoracic Aorta Replacement Through Median Sternotomy (정중 흉골 절개술을 통한 상행, 궁부, 하행 대동맥 동시 치환 수술례)

  • 이재원;이용직;이상권;주석중;윤석원
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.675-679
    • /
    • 2002
  • In patient with severe adhesion between lung and aorta, there is some limitation in approaching the distal arch or descending thoracic aorta through the usual left thoracotomy. We report a case of a successfully managed distal arch and descending thoracic aortic aneurysm through the median sternotomy without any manipulations of the lung in a 66 year old man who presented hemoptysis.

Retrograde Aortic Dissection after Thoracic Endovascular Aortic Repair for Descending Aorta - 2 case reports- (하행 대동맥 내 스텐트-도관 삽입 후 발생한 역행성 대동맥 박리 - 2예 보고 -)

  • Hong, Soon-Chang;Kim, Jung-Hwan;Lee, Hee-Jeong;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.758-763
    • /
    • 2010
  • In current era, thoracic endovascular aortic repair (TEVAR) has gained popularity. But, it bears the risk of serious complications such as treatment failure from endoleak, retrograde aortic dissection caused by injury of aortic wall at landing zone, or aortic rupture resulting from stent graft infection. We report two cases of surgical repair of retrograde aortic dissection after TAVAR applied to acute Stanford type B aortic dissection or traumatic aortic disruption.

Total Aortic Replacement - A Case Report - (대동맥 전장 치환 치험 1례)

  • Kim, Doo-Sang;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.173-177
    • /
    • 1998
  • A 28 years old pregnant woman(Gestational age 35 weeks) had been operated emergency Cesarian section for delivery and emergency graft replacement of ascending aorta and total arch for acute type A aortic dissection. 1 year and 6 months later, she underwent aortic graft replacement from descending thoracic aorta to both common iliac arteries because of further progression of aortic dissection. So far she has a complete artificial graft aorta.

  • PDF

Total Replacement of Aorta in Chronic Type 1 Aortic Dissection (만성 대동맥 박리증(DeBakey typeI) 환자의 전 대동맥 치환술 1례 보고)

  • 홍종면;노윤우
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.336-339
    • /
    • 1997
  • The surgical treatment of diseases of thoracic aorta has had much better success rate in recent years compaired to the past. Aortic aneurysms or dissections that extend along the entire thoracic aorta are usually approached in two or three stages. Recently we successfully perfofm d one-stage aortic replacement from the aortic root to the abdominal aorta in chronic DeBakey type I dissection. A 25 year-old man who had dyspnea on exertion (NYHA Fc II) and a Marfanoid feature was operated under the diagnosis of chronic type I dissection with severe aortic regurgitation. ' At operation, a huge ascending aorta with two intimal tearings was seen and the blood supply of intercostal arteries and right renal artery was done from the false lumen. Modified Bentall operation with total aortic replacement was done successfully, and the patient is being followed-up without major complications.

  • PDF