• Title/Summary/Keyword: 대기 열화

Search Result 78, Processing Time 0.038 seconds

Enhancement of Atmospherically Degraded Images Using Color Analysis (영상의 색상분석을 사용한 대기 열화 영상의 가시성 향상)

  • Yoon, In-Hye;Kim, Dong-Gyun;Paik, Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.1
    • /
    • pp.67-72
    • /
    • 2012
  • In this paper, we present an image enhancement method for atmospherically degraded images using atmospheric light and transmission based on color analysis. We first generate a normalized image using maximum value of each RGB color channel. Then, each atmospheric light is estimated from RGB color channel respectively by calculating reflectance of an image. We also, generate a transmission using gamma coefficients from the Y channel of the image. We can significantly enhance the visibility of an image by using the estimated atmospheric light and the transmission. The proposed algorithm can remove atmospheric degradation components better than existing techniques because the color prevents color distortion which is common problem of existing techniques. Experimental results demonstrate that the proposed algorithm can improve visibility be removing fog, smoke, and dust.

태양전지 모듈의 옥외실증시험을 통한 열화요인 분석

  • Kim, Hyeon-A;Choe, Jeong-Jin;Kim, Sang-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.494.2-494.2
    • /
    • 2014
  • 실리콘 태양전지는 현재 다른 태양전지 셀에 비해서 높은 변환효율 및 우수한 안정성을 가지고 있으며, 상대적으로 가격도 저렴하여 상용으로 판매되는 대다수의 모듈이 실리콘 태양전지를 사용하고 있다. 이러한 태양전지 모듈이 25년 이상 보증을 위해서는 장기 열화메카니즘 연구가 중요시 되고 있다. 따라서 태양전지 모듈을 가속열화하여 높은 내구성을 보유하고 있는지 연구가 필요하다. 본 연구에서는 결정질 실리콘 태양전지 모듈의 옥외실증 시험을 통해 일사량, 기온, 습도, 풍향, 풍속과 같은 환경인자에 따른 모듈의 성능 비교를 통해 모듈의 열화요인에 대하여 분석하였다. MYPGT (Maximal Yield Power Generation Tracking)를 활용하여 모듈의 특성을 정밀하게 측정하며, 빠른 대기환경의 변화에 따른 매시간 태양전지의 전류-전압 특성을 지속적으로 정확하게 측정함으로써 대기환경에서 받는 영향에 대해 분석하였다.

  • PDF

Early Detection of Foliar Damage Caused by Ozone Exposure with Thermal Image Analysis (식물체 잎표면의 열화상 분석을 통한 오존 피해 조기 진단)

  • 허재선;이충일
    • Korean Journal Plant Pathology
    • /
    • v.12 no.1
    • /
    • pp.132-136
    • /
    • 1996
  • 오존에 의한 식물체의 가시피해 발현 이전에 나타나는 비가시적 피해를 찾아내기 위하여 적외선 열화상장치(infrared thermography)를 이용하여 하루 8시간씩 0.3 ppm 오존에 노출된 나팔꽃(Ipomoea purpurea)잎표면의 온도분포 변화를 조사하였다. 노출 첫날에는 온도분포의 뚜렷한 변화를 볼 수 없었다. 노출 2일째, 오존 노출 2시간 결과후, 완전히 자란 제3엽의 특정 부분에서 급격한 온도분포 변화를 보였으며, 그로부터 약 4시간 경과 후에 동일 지점에서 최초의 가시적 피해가 발생했다. 급격한 온도분포 변화를 보인 부분과 최초 가시피해가 발생한 부분이 일치한 점은 가시피해 발생과 그 이전의 온도분포 변화가 밀접하게 상관되어 있다는 것을 의미한다고 하겠다. 잎표면의 열화상 분석방법을 대기오염원에 의한 식물체의 가시피해 발현 이전에 진행되고 있는 비가시적 반응의 조기진단에 적용할 수 있으며 생태환경 친화적인 대기 환경관리를 위한 대기오염원은 배출조절용 생체반응기(biosensor)로 이용 가능하겠다.

  • PDF

Prediction of Carbonation Progress for Concrete Structures Considering Change of Atmospheric Environment (대기환경변화를 고려한 콘크리트 구조물의 중성화 예측)

  • Lee, Chang-Soo;Yoon, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.574-584
    • /
    • 2003
  • The most common deterioration cause of concrete structures in urban environment is carbonation. Recently, the $CO_2$ concentration and temperature at atmosphere is sharply increased with time due to global warming phenomena. In this study, the climate scenario IS92a, which was suggested by the IPCC, is used to consider temperature and atmospheric $CO_2$ concentration change in the model of service life prediction. The modified mathematical solution, which was based on the Fick's 1st law of diffusion, was used to reflect concrete materials properties such as the degree of hydration of concrete with elapsed time, and important parameters, which associated with deterioration rate. The techniques of service life prediction are developed introducing the method of reliability and stochastic concept to consider microclimatic condition in Seoul, South Korea. From the result of service life prediction, concrete containing high W/C ratio is shown fast carbonation rate due to $CO_2$ concentration increase. It is concluded that the deterioration of concrete structures due to carbonation is insignificant problem on the conditions that below W/C 55%, well curing concrete.

Corrosion Measurement Method Using Thermographical Information (열화상 정보를 이용한 부식률 예측기법)

  • Yun, Ju-Young;Chung, Lan;Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.142-147
    • /
    • 2007
  • In order to measure corrosion level of steel reinforcement rebar which is inside reinforced concrete structure, infrared thermographic technique was employed. Experimental test parameters were four different ambient temperatures and various levels of corrosion states (0, 1, 3, 5, 7 and 10% of weight loss). After analysis of temperature distributions of concrete surface, the amount of heat flux from the concrete surface is directly proportional to the corrosion level which is inside of concrete.

Analysis of Periodic Test Policy for a Standby Unit under Three Types of Failures (세 종류의 고장형태를 지닌 대기부품에 대한 주기적 검사정책 분석)

  • Park, Jong-Hun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.3
    • /
    • pp.45-51
    • /
    • 2012
  • 대기부품은 대기기간 중에 우발적 고장이 발생할 수 있으며(type I failure), 해당상황이 장기간 방치되는 것을 방지하기 위해 주기적인 검사를 하는 것이 일반적이다. 그러나 검사가 대기기간 중 발생한 고장을 확인할 수 있게 하는 반면, 검사를 시작할 때 대기하던 부품에 부하를 가하는 과정에서 고장을 유발할 가능성이 존재하며(type II failure), 검사시간동안 대기부품을 작동시킴으로써 열화에 의한 고장발생(type III failure)의 가능성을 증가시키는 효과도 존재한다. 이에 본 논문은 주기적 검사정책을 갖는 대기부품을 대상으로 세 종류의 고장 가능성을 확률적으로 고려하여 성능분석을 실시하였으며, 성능을 평가하는 척도로 극한가용성을 사용하였다. 특히 type III failure를 고려하는 것은 기존에 연구되지 않은 부분으로 본 논문의 기여점이라 할 수 있겠다. 또한 수치해석을 통해 가용성의 관점에서 전술한 세 가지 유형의 고장특성과 검사주기와의 관계를 파악할 수 있도록 하였으며, 그 결과를 통해 높은 수준의 신뢰성 확보가 목적인 대기시스템의 효율적인 운영을 위한 의사결정시 도움이 될 수 있도록 하였다.

Effect of alkali chemical compound on paper properties for acidic papers preservation (산성지 보존을 위한 알카리 토금속 화합물이 종이물성에 미치는 영향)

  • 최찬호;신종순;마주희
    • Proceedings of the Korean Printing Society Conference
    • /
    • 2001.06a
    • /
    • pp.45-45
    • /
    • 2001
  • 자료의 보존에 있어서 종이의 열화로 인해 자료의 분석, 열화메커니즘의 해석, 종이의 보존이란 측면 하에서의 관심이 서서히 집중되고 있는 실정이며, 그 중요성도 크게 대두되고 있는 실정이다. 산성지를 중성화하는 화학적시스템, 즉, 탈산성화처리는 알카리계금속(Ca, Mg, Zn, Na)과 유기용매, 수용성용매를 이용하여 이들 약품을 종이내에 침투시켜 중성화(pH 6-8) 함으로써 종이의 주성분인 cellulose를 보다 안정화시키는 방법으로 산을 중화하여 보존성을 향상시킬 수 있는 것이다. 즉, 탈산처리란 화학적으로 종이속에 생기는 산 또는 산을 발생하는 물질을 알칼리물질로 중화하는 것이다. 또한 중화후 알칼리 물질이 종이에 잔류하면 장래에 내부적으로 발생하는 산이나 외부(대기중의 오염물질 등) 로부터 침입하는 산도 중화하여 보존성을 향상시킬 수가 있다. 따라서, 본 연구는 산성초지법에 의해 제조된 용지들의 열화특성과 알카리 토금속을 처리한 후에 알카리도를 상승시킨 용지의 열화특성을 물리·화학적 변화를 통하여 종이의 보존성을 비교 검토·규명함으로써 문(도)서의 보존체계를 마련하고자 하며, 보존과 관련된 기초자료를 얻고자 실시하였다.

  • PDF

대기압 플라즈마 소스를 이용한 태양전지 도핑에 관한 연구

  • Park, Jong-In;Kim, Sang-Hun;Jo, Tae-Hun;Yun, Myeong-Su;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.255.1-255.1
    • /
    • 2014
  • 태양전지 도핑공정은 대부분 퍼니스(furnace)도핑으로 제작된다. 퍼니스 도핑 공정은 고가의 장비와 유지 비용이 요구되며 국부적인 부분의 도핑은 제한적이다. 또한 도핑 시 온도와 공정 시간이 태양전지의 전기적 특성을 결정짓는 중요한 변수 이다. 그리하여 최근 많은 연구가 진행되는 대기압 플라즈마를 이용하여 도핑공정에 응용하고자 한다. 본 연구에서 대기압 방전 시 전원은 DC-AC 인버터를 사용하였다. 인버터의 최대 출력 전압은 최대 5kv, 주파수는 수십 KHz 이다. Ar 가스는 MFC(Mass Flow Controller)를 사용하여 조절하였다. 대기압 플라즈마를 이용한 태양전지 도핑 시 소스와 ground 거리에 따른 대기압 플라즈마의 방전을 열화상카메라(thermo-graphic camera, IR)로 온도의 변화 측정 및 광학적 발광분광법(Optical Emission Spectroscopy, OES)을 통해 불순물(질소, 산소)을 측정 하였다. 웨이퍼 도핑 후 생성된 웨이퍼를 측정 및 분석을 하였다.

  • PDF

Characteristics of microstructure and mechanical strength of ASTM A387-Gr.91 Steel deteriorated under high-temperature (고온 열화된 ASTM A387-Gr. 91 강의 미세 조직 및 기계적 강도 특성)

  • Jeong, Gwang-Hu;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.111-111
    • /
    • 2018
  • ASTM A387-Gr.91 강은 우수한 고온 강도, 크리이프 저항성 그리고 내산화성 등으로 인해 화력 및 바이오매스 발전 시설과 같은 고온 설비의 구조재료로 널리 사용되고 있다. 고온 환경에서 높은 강도는 탄화물과 탄질화물에 의한 석출강화가 주 요인으로 작용한다. 열처리 과정에서 Mo, Cr, Mn, 그리고 Fe는 구-오스테나이트 및 마르텐사이트 라스 입계에 $M_{23}C_6$ 탄화물로 석출되며, V, Nb, 및 N은 조직 내부에 미세한 MX 탄질화물로 석출된다. 따라서 합금의 고온 강도는 조직 내 석출물의 개수밀도와 크기에 크게 의존한다. 그러나 적용 환경의 특성 상 고온 노출에 따른 2차상 석출 및 조대화의 조직열화 현상이 발생하며, 이는 재료의 강도를 저하시킨다. 본 연구에서는 ASTM A387-Gr.91 강의 미세조직 열화에 따른 강도저하 및 파괴 양상을 고찰하는데 그 목적을 두었다. 본 연구에서 사용된 ASTM A387-Gr.91 강의 화학성분(wt, %)은 0.1 C, 0.38 Si, 0.46 Mn, 0.25 Ni, 8.38 Cr, 0.93 Mo, 0.18 V, 0.09 Nb, 그리고 나머지는 Fe 이다. 조직열화 및 기계적 강도저하 특성을 평가하기 위한 등온열화는 $650^{\circ}C$의 대기 환경에서 최대 1000시간동안 실시하였다. 열화된 시험편의 미세조직 및 탄화물에 대한 분석은 SEM과 EDS를 이용하여 실시하였다. 그리고 기계적 강도 평가는 인장실험과 비커스 경도시험을 통해 실시하였다. 또한 열화 시간에 따른 파단양상의 변화를 관찰하기 위해 인장시험편의 파단면을 SEM과 EDS를 이용하여 분석하였다. 그 결과, 열화에 따른 마르텐사이트 라스의 소실, 탄화물의 조대화, 그리고 2차상 석출의 조직 열화현상이 나타났다. 또한 기계적 강도는 조직 열화에 따라 저하되는 경향을 나타냈다.

  • PDF