• Title/Summary/Keyword: 대기 시료

Search Result 408, Processing Time 0.027 seconds

A Study on Nonstoichiometry and Physical Properties of the Mixed Valency Sr$_{1+x}Er _{1-x} FeO _{4-y}$ Ferrite System (혼합원자가 Sr$_{1+x}Er _{1-x} FeO _{4-y}$ 훼라이트계의 비화학양론과 물성연구)

  • Chul Hyun Yo;Kwang Sun Ryu;Mu Sil Pyun;Sung Joo Lee;Joong Gill Choi
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.99-104
    • /
    • 1991
  • Nonstoichiometric solid solutions of Sr$_{1+x}Er _{1-x} FeO _{4-y}$ system (x = 0.00, 0.25, 0.50, 0.75 and 1.00) with layered $K_2NiF_4$ type structure were prepared at 1350$^{\circ}$C under atmospheric pressure. By the analysis of X-ray diffraction, the crystallographic structures of the solid solution of all compositions were found to be pseudo-tetragonal system. Nonstoichiometric chemical formulas have been determined by Mohr salt analysis. It shows that the amount of Fe$^{4+}$ increases with increasing x up to 0.50 and then decreases, and the value of oxygen nonstoichiometry increases with increasing x value. Mixed valency states of Fe$^{3+}$ and Fe$^{4+}$ in the sample were identified again by Mossbauer spectroscopic analysis at 298 K. Electrical conductivity varied within the semiconductivity range of 10-2 ∼ 10-7(${\Omega}$-1cm-1), activation energy for electrical conduction decreased with the increment of the mole ratio of Fe$^{4+}$ or ${\tau}$ value. The conduction mechanism could be explained by the hopping model of the conduction electrons between the valency states of Fe$^{3+}$ and Fe$^{4+}$.

  • PDF

Sedimentary Environments in the Coastal areas of Imja to Nakweol Islands (임자도-낙월도간 해역의 퇴적환경)

  • 유환수;고영구
    • 한국해양학회지
    • /
    • v.28 no.3
    • /
    • pp.241-258
    • /
    • 1993
  • To investigate the sedimentary environments on the coastal areas of Imja to Nakweol islands which show very complex shorelines and several zonal sand ridges in NE-SW direction, southwestern coast of Korea, a total of forty samples were taken by a grab sampler and sedimentological and micropaleontological studies on those samples were carried out. The present study area are classified into muddy sandy gravel, sand, city sand, sandy silt and silt facies. With statistical moment parameters such as mean, sorting, skewness and ketosis for the sediments in the study area, the sediments are generally categorized as shallow sedimentary facies. The characters that are observed in quartz grains among the sandy sediments of the study area imply the existence of high energy environments, temporal exposures in atmosphere and the mixing of clastic sediments of the several different origins. In the sediments of the study area, one genera belonging to six silicoflagellata species and five genera belonging to five nannoplankton species were detected. On the basis of the micro-organism assemblage, the study area seems to be influenced by active reworking dominantly under warm water masses. In addition, organic matter ad carbonate contents in the sediments did not show a definite relation with the occurrences of the micro-organisms in the study area.

  • PDF

Enhanced Migration of Gasohol Fuels in Clay Soils and Sediments (Gasoline-ethanol(Gasohol)혼합액의 점토층 내 이동에 대한 연구)

  • Hee-Chul Choi;W.M. Stallard;Kwang-Soo Kim;In-Soo Kim
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.1
    • /
    • pp.67-79
    • /
    • 1996
  • Clay soils typically have low hydraulic conductivities in the presence of high polarity pore fluid, such as water. Low polarity fluids, such as hydrocarbon fuels and halogenated organic solvents, typically cannot migrate into clay pores because they cannot displace the pore water. Oxygenated additives in gasoline, such as alcohols and methyl-tert-butyl ether, are increasingly used to control air pollution emissions. These relatively polar and highly water-soluble compounds may facilitate displacement of pore water and enhance migration of fuels and solvents through clay-rich soil strata. In the reported research, the migration of gasoline-alcohol fuel mixtures (gasohol) through consolidated clay was examined. Prepared kaolinite clay samples were consolidated from slurry, and various combinations of gasoline, alcohol, and water were applied to the clays under 152 Pa gauge pressure. Movement of the fluids into the clay samples was monitored by measur ing displaced pore fluid and by magnetic resonance imaging of the samples. The structures of selected samples were examined using environmental scanning electron microscopy. Results of the research suggest that alcohol added to hydrocarbon fuels can enhance migration through some clays significantly. Gasoline did not migrate appreciably into water saturated clay, even after 14 days under pressure. The gasohol mixture migrated readily into the clay in only 20 minutes. Increased hydraulic conductivity of the clay in the presence of gasohol is hypothesized to be due to the collapse of the clays pore structure when ethanol is present, creating larger pores. Increasing pore diameter decreases the capillary pressure needed for the gasohol to replace water and allows gasohol to migrate through the clay.

  • PDF

An Application of Solenoid Eddy Current Sensor for Nondestructively Inspecting Deterioration of Overhead Transmission Lines due to Forest Fires (산불에 의한 가공송전선의 열화특성을 비파괴적으로 검출하기 위한 솔레노이드 와류센서의 응용)

  • Kim, Sung-Duck;Kim, Young-Dal;Jeong, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.404-415
    • /
    • 2000
  • This paper describes several performances and nondestructive inspection for deterioration due to forest fires in overhead transmission lines. After discussing corrosion mechanism such as atmospheric and galvanic corrosion for aged ACSR conductors and its detection for them are presented. Through impedance analysis of a solenoid coil, it is shown that the eddy current sensor may be available to inspect severe fault or local corrosion. As the solenoid coil changes its impedance when the test conductor is inserted into the coil, it can be possible to measure deterioration degree caused by forest fires. Tensile strength, extension rate and sensor impedance are tested for some samples degraded by artificial fire. As increasing blazed period to some extent, the strength of aluminum strand begins to be reduced remarkably, while galvanized steel strand holds the similar strength to the initial value, despite of appearing a little loss of zinc layer. In general, it is shown that the sensor impedance would be increased while the tension load of conductor is reduced and the extension rate is contrarily increased. Therefore, the sensor output could exhibit the changes of mechanical performances, and would be used to detect such deterioration caused by forest fire in ACSR conductors built on the ridge of mountains. Finally, it was verified that the solenoid coil could be applicable to obtain any crucial inform for serious deterioration due to forest fires.

  • PDF

Measurements of Greenhouse Gas from the Manure in the Piggery (축산 돈사에서 온실가스 측정 방법에 대한 연구)

  • Kam, D.H.;Park, K.H.;Choi, D.Y.;Jung, M.S.;Min, B.R.;Lee, D.W.;Kim, J.K.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.155-162
    • /
    • 2011
  • This study was conducted to suggest the measurement procedure and to build up national greenhouse gas inventory database of animal agricultural sector by assessing methane and nitrous oxide emissions according to IPCC guidelines for national greenhouse gas inventory report in order to correspond to the Climate Change Convention. Ten house-made steady-state Half dome floating chambers were used to collect air samples emitted from slurry stored in the pit under the slat. Those chambers were spread out in order that air samples might represent the whole area of slurry under the slat. Fresh air was pumped into the chambers by $5{\sim}9{\ell}/min$ and air inside the chambers was sampled by $1{\ell}/min$. Surplus air by the higher flow rate of fresh air than sampling flow rate was passed through a hole on the top of chambers. Nitrous oxide fluxes measured from 10 locations would be negligible as concentrations between background air and sampled air from the chambers were within the error range. However, mean $CH_4$ fluxes were $0.15{\sim}1.02mg/m^2{\cdot}s$. The application of continuous greenhouse gas measurement techniques would be preferred if the patterns of greenhouse gas emissions are considered.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Leaching Capacity and Rate of Alkali Ions from Hardened Cement Paste (시멘트 경화체의 알칼리이온 침출성능 및 침출속도)

  • Shim, Hyun-Bo;Hwang, Jun-Pil;Ann, Ki-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.111-118
    • /
    • 2014
  • The present study concerns the leachability of alkali ions from hardened cement paste in terms of an increase in the pH together with the rate of alkali leaching. To evaluate the influence of mix design on the leaching capacity and rate of alkali, different water-cement ratios (W/C) and binders were used to manufacture paste specimens. The cement paste was made in the form of rectangular bucket where deionised water was subsequently supplied as solvent media. Then the specimen was wrapped in polythene film to avoid contact to atmospheric conditions, which may affect the water chemistry in the bucket. The pH of media was monitored until no further change in the pH value was observed, of which value then used to calculate the leaching capacity and rate. The influence of binder on the pH of solvent is more dominant than that of water to cement ratio: OPC paste produced the highest level of alkali leaching, whilst 30% PFA and 60% GGBS pastes imposed lower level of alkali leaching. After the monitoring of the pH, the inner bucket was ground with an increment of 1.0 mm to measure the leaching influence using the suspension consisting of paste powder and deionised water. It was found that the impact zone for OPC was about 7-8 mm, whilst 30% PFA and 60% GGBS had deeper impact depth of the alkali leaching.

Characteristics of Microwave Leaching for the Removal of Bi, As from the Sulfide Mineral Concentrate (황화광물정광으로부터 Bi, As 제거를 위한 마이크로웨이브 용출 특성)

  • On, Hyun-Sung;Togtokhmaa, B.;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.137-147
    • /
    • 2018
  • The aim of this study was to leach penalty elements, such as Bi and As, effectively through microwave leaching of a gold concentrate sample containing penalty elements with nitric acid solution. For this purpose, the time effect of microwave leaching, nitric acid concentration effect, and sample addition effect in a microwave were examined. The experiment, demonstrated that the leaching rate of penalty elements increased as microwave leaching time and nitric acid concentration increased and concentration addition decreased. When a microwave heating experiment was carried out on the concentrate and ore minerals, Bi was removed by as much as 90%, and the phase of arsenopyrite was transformed in the order of arsenopyrite (FeAsS), pyrrhotite (FeS), and hematite ($Fe_2O_3$). When the X-ray diffraction (XRD) analysis was carried out with solid residue, elemental sulfur and anglesite were identified. The intensity of the XRD peaks of elemental sulfur and anglesite increased, and the peaks were sharper when the microwave leaching time was 12 min instead of 1 min, the nitric acid concentration was 4 M in rather than 0.5 M, and the concentration addition was 30 g rather than 5 g. This was probably because more elemental sulfur and anglesite were generated in the leaching solution as the leaching efficiency increased. Bi can be leached as valuable elements in the leaching solution through microwave leaching processes while they are released to the environment through a microwave heating processes.

A Comparative Study on Radiochemical Pre-treatment Methods for Airborne Uranium-Isotropic Analysis (공기 중 우라늄 동위원소 분석을 위한 방사화학 전처리방법에 대한 비교 분석 연구)

  • Kang, Han-Byeol;Chung, Heejun;Park, Seunghoon;Shin, Jung-Ki;Kwak, Sung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.101-109
    • /
    • 2015
  • Alpha spectrometry is typically used for the assessment of uranium particle concentrations and its accuracy can be directly related to the accuracy in which the radiochemical pre-treatment is conducted. Ashing and alkali fusion methods are typically used but the ashing method requires longer analysis time and the alkali fusion method is extremely costly. Therefore, a new pre-treatment method using ultrasonic cleaning was developed and its experimental result was compared against the two conventional methods in terms of pre-treatment time, convenience, cost, and recovery rate of a target material. The results that were obtained by the conventional methods(ashing and alkali fusion) and the new method were compared. Consequently, even though the shorter pre-treatment time was required, the new technique showed almost same recovery rate comparing with two conventional methods. The new method was also featured by its relatively lower cost and a simpler process than two conventional methods.

Corrosion and Strength Changes of Agricultural Steel Pipes Elapsed 20 Years under the Greenhouse Environment (온실 환경 하에서 20년 경과된 농업용 강관의 부식 및 강도변화)

  • Nam, Sang-Woon;Ryu, Hee-Ryong;Choi, Man-Kwon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.196-201
    • /
    • 2020
  • In order to increase the durability of the pipe framed greenhouse, galvanized steel pipes with four corrosion protection treatments were installed in the greenhouse. After 20 years, experiments on surface corrosion and strength change were conducted. Control (untreated) pipes exposed in the atmosphere showed a 1.3% reduction in strength, but little difference from other treatments. The strength of heavy protective coating pipes buried in the ground decreased by 0.6%, showing little change, but untreated pipes decreased by 15.7%. And antirust paint and asphalt coating pipes decreased by 4.2~4.4%. Pipes exposed in the atmosphere did not show severe corrosion in all samples. There was no change in heavy protective coating pipes, and no rust was found in antirust painting pipes either and there was only slight discoloration. Asphalt coating pipes discolored black and some rust was found, and untreated pipes were rusted by 20~30% of the surface. However, untreated pipes buried in the ground were completely rusted, and asphalt coating pipes were rusted by 80~90% of the surface. Antirust painting pipes were rusted by 20~30%, and heavy protective coating pipes did not change almost. The heavy protective coating treatment showed a clear corrosion protection effect even in the parts buried in the ground, and the antirust painting treatment also showed some corrosion protection effect. Therefore, it is judged to be applicable to the field of pipe framed greenhouses.