• Title/Summary/Keyword: 단일 현장타설말뚝

Search Result 30, Processing Time 0.026 seconds

Proposed Optimized Column-pile Diameter Ratio with Varying Cross-section for Bent Pile Structures (단일 현장타설말뚝의 변단면 분석을 통한 최적 기둥-말뚝 직경비 제안)

  • Kim, Jaeyoung;Jeong, Sangseom;Ahn, Sangyong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1935-1946
    • /
    • 2013
  • In this study, the behavior characteristics of bent pile structures with varying cross-section was examined through the measured results of field load test. A framework for determining the bending stress is calculated based on the stresses in the circumference of the pile using 3D finite element analysis. It is found that the bending stress near the pile-column joint changes rapidly and fracture zones occurs easily at variable cross-sections in bent pile structures. Also, the optimized column-pile diameter ratio was analyzed through the relationship between the column-pile diameter ratio and lateral crack load ratio. Based on this study, the optimized column-pile diameter ratio can be obtained near the inflection point of the curve between the column-pile diameter ratio and lateral crack load ratio. Therefore, a present study by considering the optimized variable cross-section condition would be improved bent pile structures design.

Simplified Analysis of Pile Bent Structures and Minimum Reinforcement Ratio (단일 현장타설말뚝의 간편해석 및 최소 철근비 분석)

  • Kim, Jae-Young;Hwang, Taik-Jean;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.5
    • /
    • pp.33-43
    • /
    • 2011
  • In this study, simplified analysis (discrete analysis of column and pile) of pile bent structures was performed on the basis of the equivalent base spring model. And the minimum reinforcement ratio in pile bent structures was evaluated by taking into account various factors. To obtain the detailed information, simplified analysis was performed for column-pile interactions and the behavior of a column-pile was estimated and highlighted. Based on this study, it is shown that previous design method based on virtual fixed point theory cannot adequately predict the physical behavior of pile bent structures. It is found that the maximum bending moment is located within craking moment of the pile when material non-linearity is considered. It is also found that the minimum reinforcement ratio (=0.4%) is appropriately applicable for the optimal design of pile bent structure under ultimate lateral loading.

Analysis of Optimized Column-pile Length Ratio for Supplementing Virtual Fixed Point Design of Bent Pile Structures (단일 현장타설말뚝의 가상고정점 설계를 보완한 상부기둥-하부말뚝 최적 길이비 분석)

  • Jeong, Sangseom;Kim, Jaeyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1915-1933
    • /
    • 2013
  • In this study, the virtual fixed point analysis and 3D fully modeling analysis for bent pile structures are conducted by considering various influencing factors and the applicability of the virtual fixed point theory is discussed. Also, the optimized column-pile length ratio is analyzed for supplementing virtual fixed point design and examining a more exact behavior of bent pile structures by taking into account the major influencing parameters such as pile length, column and pile diameter, reinforcement ratio and soil conditions. To obtain the detailed information, the settlement and lateral deflection of the virtual fixed point theory are smaller than those of 3D fully modeling analysis. On the other hand, the virtual fixed point analysis overestimates the axial force and bending moment compared with 3D fully modeling analysis. It is shown that the virtual fixed point analysis cannot adequately predict the real behavior of bent pile structures. Therefore, it is necessary that 3D fully modeling analysis is considered for the exact design of bent pile structures. In this study, the emphasis is on quantifying an improved design method (optimized column-pile length ratio) of bent pile structures developed by considering the relation between the column-pile length ratio and allowable lateral deflection criteria. It can be effectively used to perform a more economical and improved design of bent pile structures.

Analysis of Plastic Hinge on Pile-Bent Structure with Varying Diameters (변단면 단일 현장타설말뚝의 소성힌지 영향분석)

  • Ahn, Sangyong;Jeong, Sangseom;Kim, Jaeyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3C
    • /
    • pp.149-158
    • /
    • 2010
  • In this study, the behavior of Pile-Bent structure with varying diameters subjected to lateral loads were evaluated by a load transfer approach. An analytical method based on the beam-column model and nonlinear load transfer curve method was proposed to consider material non-linearity (elastic, yielding) and P-${\Delta}$ effect. For an effective analysis of behavior Pile-Bent structure, the bending moment and fracture lateral load of material were evaluated. And special attention was given to lateral behavior of Pile-Bent structures depending on reinforcing effect of materials and ground conditions. Based on the parametric study, it is shown that the maximum bending moment is located within a depth (plastic hinge) approximately 1~3D (D: pile diameter) below ground surface when material non-linearity and P-${\Delta}$ effect are considered. And distribution of the lateral deflections and bending moments on a pile are highly influenced by the effect of yielding. It is also found that this method considering material yielding behavior and P-${\Delta}$ effect can be effectively used to perform the preliminary design of Pile-bent structures.

Evaluation of Drilled Shaft's End Condition by Impact-Echo Method (충격반향기법에 의한 현장타설 말뚝기초의 선단 조건 평가)

  • Kim, Dong-Soo;Kim, Hyung-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.2
    • /
    • pp.89-97
    • /
    • 2003
  • Experimental model studies were carried out to evaluate the end condition for drilled shafts by applying elastic impact on the top of the shaft, which is one of the various methods using stress waves. Typical impact responses corresponding to the various end conditions including free, fixed, rock-socketed, and soft-bottom with good and poor side contact conditions, were investigated. In order to simulate these renditions, mock-up shaft models made of cement mortar were used. Small-scale laboratory experiments were also performed, and field tests were carried out for the shafts that were socketed into weathered rock. It is found that the rock-socketed condition and depth of penetration into rock ran be identified from the reflection at the interface between the soil and rock in the waveform. The soft bottom rendition can be identified, only when the side contact between shaft and surrounding rock is poor, whereas it cannot be identified when the side contact is good because the waveform is similar to that of fixed end rendition.

Proposal of a New Design Method of the Pile-Bent Structure Considering Plastic Hinge (단일 현장타설말뚝의 소성힌지를 고려한 최적설계법 제안)

  • Ahn, Sang-Yong;Jeong, Sang-Seom;Kim, Jae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.91-101
    • /
    • 2011
  • In this study, a new design method of Pile-Bent structure considering plastic hinge was proposed on the basis of the beam-column model. To obtain the detailed informations, the optimized cross-section ratio between column and pile was analyzed to induce the plastic hinge at the joint section between the pile and column. Base on this study, the optimized diameter ratio of pile and column can be obtained below the inflection point of the bi-linear curve depending on the relations between column-pile diameter ratio ($D_c/D_p$) and normalized lateral cracking load ratio ($F/F_{Dc=Dp}$). Moreover, through comparisons with field cases to find out in-depth limit in which minimum concrete-steel ratio could be applied, in-depth limits ($L_{As=0.4%}$) normalized by the pile length ($L_p$) proportionally decrease as the pile length ($L_p/D_p$)increases up to $L_p/D_p=17.5$, and beyond that in-depth limit converges to a constant value (${\simeq}0.3$).

Estimation of Appropriate Reinforcement Length of Casing for the Pile of Pile Bent System through Numerical Analysis (수치해석을 통한 단일형 현장타설말뚝 외부강관의 적정 보강길이 산정)

  • Yang, Wooyeol;Kim, Wanho;Lee, Kangil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.6
    • /
    • pp.5-15
    • /
    • 2021
  • One of the construction methods applied as a pier foundation type is a single type cast-in-place pile. In applying a pile bent system as a foundation type, the main concern in designing can be said to secure the lateral bearing capacity of pile structure in system. In addition, to increase the rigidity of the pile structure, a method of increasing the lateral bearing capacity by reinforcing the pile structure with a casing has been used. However, although the reinforcing effect and appropriate reinforcing length of casing may vary depending on the soil conditions, there is insufficient studies on this, and for this reason, the entire pile structure in a pile bent system is reinforced with a casing, in the field. In addition, if the length of the entire pile is reinforced with a casing, it may lead to delays in construction and increase in construction costs. That is, in order to more effectively reinforce the pile structure with a casing, it is necessary to study the lateral bearing characteristics of the reinforced pile structure in system. And it should be determined the appropriate reinforcing length of the casing from the evaluated bearing characteristics. Therefore, in this study, the lateral bearing characteristics of piles applied with the reinforcing length of casing for each condition were evaluated through a numerical analysis. And, based on the analysis results, the appropriate reinforcing length of casing was proposed. As a result of the study, it was found that in order to effectively increase the lateral bearing capacity of pile structure, the reinforcing length of casing should be applied twice the influence range of the bending behavior of the pile, 1/β.

Theoretical Considerations in the Application of Impact Echo and Impulse Response Techniques to Integrity Tests on Drilled Shafts (II) (현장타설말뚝의 비검측공 건전도시험법에 관한 해석적 고찰 (II))

  • 이병식;이원구
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.107-114
    • /
    • 2001
  • 비검측공 시험법을 현장타설말뚝의 건전도 평가 목적으로 적용함에 있어서 시험법의 적용성을 향상시키기 위한 연구가 진행되어 오고 있다. 본 논문에서는 같은 맥락에서 수행되어 온 일련의 해석적 연구 결과 중 시험법의 해상도에 관한 문제와 말뚝 주변 및 선단지반의 강성이 비검측공 시험결과에 미치는 영향에 관해 다루었다. 본 논문에서 수행한 연구결과에 의하면 충격응답기법의 해상도를 평가하기 위해서는 말뚝재료에 대한 지반의 강성비($V_{s}$ /$V_{c}$)와 말뚝의 길이에 대한 직경의 비(L/D)에 의존하는 기존 평가기준에 부가하여 말뚝의 상대적인 체적변화가 필히 고려되어야 한다는 결론을 얻었다. 한편, 말뚝이 수평으로 층이 진 주변 지반을 통과하여 말뚝선단부를 지지하는 지반(선단지반)에 근입되거나 지지되는 경우에 말뚝의 자유단 혹은 고정단 경계 조건은 주변 지반과 선단 지반의 강성비와 선단 지반에 대한 말뚝의 근입깊이에 따라 변화한다는 사실을 규명하였다. 말뚝의 건전도 평가 시에 사용하게 되는 말뚝의 공진주파수가 이들 조건에 따라 변화하므로 결과적으로 시험결과분석에 있어서 이들 영향이 필히 고려되어야 한다는 결론을 얻었다.

  • PDF

Horizontal Behaviour Characteristics for Single Drilled Shaft Embedded in Granite Gneiss (화장편마암에 근입된 단일현장타설말뚝의 수평거동특성)

  • Yea, Geu-Guwen
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.493-499
    • /
    • 2008
  • In order to evaluate the lateral behavior characteristics of single drilled shaft embedded in granite gneiss, a lateral load test was conducted in field. Horizontal displacement according to lateral load were measured along with the depth by an inclinometer installed in the shaft. In this study, We have evaluated horizontal displacement characteristics comparing the measurement values with calculating results by theoretical formula. Based on the comparison, the Chang's method was similar with the measurement values even though it was slightly underestimated. However, the finite analysis method and p-y method was overestimated, especially on the upper part of the ground.

Application of Virtual Fixed Point Theory and Discrete Analysis for Pile Bent Structures (단일 현장타설말뚝의 가상고정점 설계 및 분리해석 적용성 평가)

  • Kim, Jae-Young;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.7
    • /
    • pp.57-74
    • /
    • 2013
  • In this study, the virtual fixed point analysis and 3D full-modeling analysis for pile bent structures are conducted by considering various influencing factors and the applicability of the virtual fixed point theory is discussed. Also, a discrete analysis calculating separately both the superstructure and substructure of pile bent structures is performed on the basis of an equivalent base spring model by taking into account the major influencing parameters such as soil conditions, combined loading and pile diameter. The results show that the settlement and lateral deflection of the virtual fixed point theory are smaller than those of 3D full-modeling analysis. On the other hand, the virtual fixed point analysis overestimates the axial force and bending moment compared with 3D full-modeling analysis. It is shown that the virtual fixed point analysis cannot adequately predict the real behavior of pile bent structures. It is also found that discrete analysis gives similar results of lateral deflection and bending moment to those of unified analysis. Based on this study, it is found that discrete analysis considering column-pile interaction conditions is capable of predicting reasonably well the behavior of pile bent structures. It can be effectively used to perform a more economical design of pile bent structures.