• Title/Summary/Keyword: 단일 기포

Search Result 59, Processing Time 0.021 seconds

Evaluation of Flotation Efficiency and Particle Separation Characteristics of Carbon Dioxide Bubbles using Collision Efficiency Model (단일포집자충돌(SCC) 모델을 이용한 이산화탄소기포의 입자분리특성과 부상효율 평가)

  • Lee, Jun-Young;Kim, Seong-Jin;Yoo, Young-Hoon;Chung, Paul-Gene;Kwon, Young-Ho;Park, Yang-Kyun;Kwak, Dong-Heui
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.129-136
    • /
    • 2012
  • In this century, scientists realized that carbon dioxide gas in the atmosphere cause a greenhouse effect which affects the planet's temperature. Therefore lots of attempts have carried out to decrease the discharge of carbon dioxide gas in the field. The dissolved carbon dioxide flotation (DCF) process was developed as an alternative of DAF process to decrease the discharge and reuse of carbon dioxide as well as to save energy consumption. To investigate the particle separation characteristics and the flotation efficiency of carbon dioxide, SCC model was employed in the DCF process which has been applied extensively for the evaluation and simulation in the DAF process. The simulation results by the SCC model revealed the predicted curve of flotation efficiency became decreased gradually over the optimal pressure range of saturator about 1.6 atm in accordance with the experiment results of the DCF pilot plant and the size distribution and the bubble volume concentration of $CO_{2}$ bubbles depending on the operation pressure of saturator. The findings through the simulation results led to the conclusion that there was no significant difference between $CO_{2}$ bubbles and air bubbles, affecting on the practical flotation efficiency, in terms of the initial collision and attachment efficiency.

Optimum Size Combination of Heat Exchangers in a Small Gifford-Mchon/ Joule-Thomson Refrigerator (소형 Gifford-McMahon/Joule-Thomson 냉동기에서 열교환기의 최적 조합)

  • 김영률;이상용;장호명
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2196-2202
    • /
    • 1992
  • The optimum size combination of heat exchangers in a Joule-Thomson(J-T) circuit for small cryogenic systems has been sought analytically, when the circuit is combined with a two-stage Gifford-McMahon(GM) cooler. Full thermodynamic cycle analysis was carried out to predict the performance of the combined refrigeration system. Relevant convective heat transfer coefficients, the computerized properties of helium, and the refrigeration capacity curve of a typical GM cooler have been used in the analysis. The result showed that, by changing the configuration(heat exchanger area ratio) of the system, the performance of the commonly-used GM/J-T refrigerators could be optimized. For the maximum refrigeration performance, the optimum mass flow rate of the refrigerant and the relative size between the heat exchangers have been obtained, when the cooling load was 0.1W at 3.995K with the total heat exchanger area being given.

The Effect of Temperature and Flow Rate of Eluent on the Separation of Adjacent Lanthanides (La : Ce, Ce : Pr, Pr : Nd) with Displacement Chromatography (치환크로마토그래피에서 온도와 용리액의 흐름속도가 란탄족 원소들 (La : Ce, Ce : Pr, Pr : Nd) 의 분리에 미치는 영향)

  • Ha, Yeong Gu;Song, Gi Hun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.9
    • /
    • pp.660-666
    • /
    • 1994
  • The effects of temperature and flow rate of eluent on the separation of adjacent lighter lanthanide pairs (La : Ce, Ce : Pr, Pr: Nd) have been studied with displacement chromatography. Two serial columns packed with Amberlite 120 cation exchange resin are used for loading and separation. The retaining ion is $H^+$ ion and the eluent is 0.012M and 0.015M of EDTA solution. The columns and the eluent are maintained at the temperature of 90$^{\circ}C$ and pressurized to reduce vaporizing in the ion-exchange resin column. The eluated solution is analyzed directly with ICP-AES. The separation factors of the lanthanide pairs, La: Ce, Ce :Pr, and Pr: Nd, are 4.6, 2.8, and 1.9, respectively and are higher than that from theoretical calculation at 25$^{\circ}C$. When the flow rate is reduced from 2.5 ml/min to 1.5 ml/min, the HETP is reduced from 1.60 cm to 0.88 cm. The separation efficency can be improved at lower flow rate of eluent and higher operating temperature. The recoveries of pure lanthanides than 99.9% are 49∼77% from this separation.

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

Characteristics of Growth and Oil Production of Peppermint Cells in an Air-bubble Bioreactor (기포 생물반응기에서 페퍼민트 세포의 생육 및 정유 생산 특성)

  • 송은범;이형주
    • KSBB Journal
    • /
    • v.8 no.5
    • /
    • pp.495-503
    • /
    • 1993
  • To investigate the characteristics of growth and oil production of peppermint cells during a batch culture, cells derived from peppermint callus was cultivated in an air bubble reactor. During the batch culture, effects of inoculum size, abiotic stress, yeast elicitor, and two stage culture on the cell growth, the productivity of oleolesin, and the formation of flavor components were determined and also the sugar concentrations and kinetics of cell growth were analyzed. Among the various sizes of inoculum, the culture with 2.0% packed cell volume inoculum showed the optimum condition for cell growth in the proposed bioreactor, and the cell yield and essential oil production reached to 5.7g/1 and 0.109g/1, respectively. When the abiotic stress of daily 8hr dark and $10^{\circ}C$ cold treatments were given to the culture cell growth decreased but essential oil production increased to 0.546g/l. In a modified Lin-Staba medium in which 100mg/l yeast extract as an elicitor was added to the culture, the cell growth and oil production increased, and menthol content was 22.5% of oil. In the two stage culture, in which the basic culture conditions of 27$^{\circ}C$, light, and without elicitor were employed during the first six days followed by the second stage with daily 8hr treatment of cold and dark condition, and also with yeast extract as an elicitor, cell growth decreased after eight days, essential oil production was not increased, and menthol was not detected. Dry cell yield was 0.38g dry cell/g sugar and specific growth rate was 0.25 day-1. The major terpenoid in the oil was not the menthol but pulegone and piperitone, precursors of menthol were accumulated. However, when yeast elicitor was added, menthol was produced to the level of 22.5% which was the highest value in the peppermint cell culture reported so far.

  • PDF

Engineering Properties of Lightweight Foaming Grouting Materials for Underground Cavities (지반 공동의 충진을 위한 발포성 경량그라우트재의 공학적 특성)

  • Han, WooJin;Lee, Jong-Sub;Byun, Yong-Hoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.2
    • /
    • pp.5-12
    • /
    • 2018
  • Underground cavities could induce road subsidence, which have been frequently observed in urban areas. Therefore, adequate backfilling materials and the restoring methods of the cavities are required to prevent the road subsidence. The objective of this paper is to evaluate the suitability of backfilling methods using foaming lightweight grouting materials considering the flow values, unit weights, and air contents at slurry and expanded states, and unconfined compressive strengths. The grouting materials consist of water, cement, and foaming agent whose proportions of water, cement, and foaming agent are 25: 25: 1.0 and 25: 25: 1.2. The flow values of the two materials are greater than 200 mm, and their unconfined compressive strengths at 28 days age are smaller than 1.3 MPa. From the results, the two proportions of materials are expected to be effectively used as a backfilling material. However, the material components should be carefully mixed because poor mix of these materials could induce non-homogeneous distribution of air bubbles. The unexpectedly non-homogeneous distribution of air bubbles may induce significant cracks or additional cavities.

Effects of Multiple-CycleOperation and $SO_2$ Concentration on the Absorption Characteristics of $CO_2$ by means of Limestone (석회석의 $CO_2$의 흡수특성에 미치는 흡수/재생 반응의 반복횟수와 $SO_2$ 농도의 영향)

  • Ryu Ho-Jung
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.203-211
    • /
    • 2005
  • To investigate the effects of the number of multiple-cycles and $SO_2$ concentration on $CO_2$ absorption characteristics by means of limestone, $CO_2$ capture capacity has been measured in a bubbling fluidized bed reactor (0.1m 1.D., 1.17m high). Danyang limestone was used as a $CO_2$ sorbent and the number of cycles $(\~10th\;cycle)$ and $SO_2$ concentrations (0, 2000, 4000 ppm) were considered as variables. The measured $CO_2$ capture capacity decreased as the number of cycles increased and it showed $50\%$ or initial value after 10 cycles. Moreover, $CO_2$ rapture capacity decreased with 501 concentrations. For three different $SO_2$ concentrations, the total CaO utilization was almost the same but $SO_2$ capture capacity increased and $CO_2$ capture capacity decreased as $SO_2$ concentration increased. These results suggest that $SO_2$ capture reaction is predominant over $CO_2$ capture reaction in the simultaneous $CO_2/SO_2$ capture conditions.

A Clinical Study of Congenital Duodenal Obstruction (선천성 십이지장 폐쇄증의 임상적 고찰)

  • Huh, Young-Soo;Suh, Bo-Yang;Kwun, Koing-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.39-48
    • /
    • 1990
  • Congenital duodenal obstruction in the newborn infant may be due to a variety of causes. Duodenal obstruction often presents with bilious vomiting and upper abdominal distention. Diagnosis is usually established on plain x-ray of the abdomen by the classic finding of the double-bubble. In the period July 1986 to June 1990, 16 patients with congenital duodenal obstruction were operated and the following results were obtained. 1. Sixteen patients were comprised of 11 males and 5 females, the ratio of male and female was 2.2:1. 2. Thirteen patients(81%) had been admitted to our hospital during one month of life. 3. Congenital duodenal obstruction was in 16 cases; malrotation in eight(50%), annular pancreas in six(38%), type 1 atresia in one(6%), and wind-sock anomaly in one(6%). 4. There were two premature patients and six patients of small for gestational age. 5. Overall, bilious vomiting, occurring in three fourths, was the single most frequent presenting complaint. 6. Polyhydramnios occurred in two of the patients. 7. Diagnosis was possible with clinical symptom and simple abdomen. 8. The operative procedures performed were ; duodenoduodenostomy in five, duodenojejunostomy in two, excision of wind-sock membrane in one, and Ladd's procedure in eight. 9. A total of ten asociated congenital anomalies were found in six patients. 10. Postoperative complications occurred in five cases(31%).

  • PDF

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF