• Title/Summary/Keyword: 단일굴곡

Search Result 34, Processing Time 0.016 seconds

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

A Comparison of Outcomes after Early and Delayed Reconstruction in the Acute Posterior Cruciate Ligament Injuries (급성 후방십자인대 손상 환자에서 조기 재건군과 지연 재건군의 결과 비교)

  • Lee, Yong Sik;Lee, Soo Won;Seo, Byung Ho;Kim, Yoon Gi
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose: This study performed to compare degree of joint stiffness and clinical results between early and delayed reconstruction of acute posterior cruciate ligament (PCL) injuries. Materials and Methods: Thirty-two Patients who underwent PCL reconstruction between March 2008 and October 2011 enrolled this study. We performed transtibial single bundle reconstruction using the allo-achilles tendon in all cases. We divided the patient into two groups, early reconstruction group underwent surgery before a week, delayed reconstruction group underwent surgery after 3 weeks, before 6 weeks. All the patients underwent aggressive joint motion exercise till surgery and enrolled post operative rehabilitation program. We checked posterior drawer stress radiography, range of motion, the Lysholm score, the International Knee Documentation Committee (IKDC) score and the Tegner score to evaluate the results. Results: At the final follow up the Lysholm score was 92.1 in the early group and 93.8 in the delayed group. All the cases were rated above B (near normal) on IKDC score (p=0.808, p=0.722). The Tegner score was 6.6 in the early reconstruction group and 6.2 in the delayed group (p=0.480), The average of maximum flexion and extension angle was $133.9^{\circ}$, $1.4^{\circ}$ in the early group and $133.6^{\circ}$, $1.1^{\circ}$ in the delayed group (p=0.560, p=0.581), no complication such as deep vein thrombosis or infection, no difference in posterior drawer stress radiography (p=0.750). Conclusion: We could obtain satisfactory clinical results in both the early and delayed reconstruction groups of acute PCL injuries. Therefore, the early reconstruction of PCL performed before a week could be one of the treatment options for acute PCL injury.

  • PDF

Clinical Study of Childhood Accidents from a Hospital Over Ten Years with Regard to Foreign Body Aspiration (단일병원에서 관찰한 최근 10년간의 소아 우발사고에 관한 연구 : 이물흡인을 중심으로)

  • Kim, Cheol-Min;Song, Jun-Young;Kim, Ja Hyung;Kim, Ki Soo;Hong, Soo-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.9
    • /
    • pp.1134-1140
    • /
    • 2002
  • Purpose : Childhood accidents have been increasing recently. Accidents rank as the leading cause of childhood mortality and morbidity. We performed this study to evaluate the causes of childhood accidents. Methods : The authors analysed retrospectively the medical records of 6,410 cases of childhood accidental injuries who visited the emergency room of Asan Medical Center from January 1990 to December 1999. Results : The most common type of accidents was trauma which accounted for 5,038 cases of the total accidents, followed by falls, burns, foreign body aspiration, and poisoning. The most common age of foreign body aspiration was under two years old and the male to female ratio was 2 to 1. The most common site of foreign body aspiration was the esophagus and the stomach, followed by the respiratory tract. In airways, the right and left main bronchus were the most common site for foreign body aspiration and were accompanied by the highest mortality. The most common foreign body in the gastrointestinal tract and respiratory tract were coins and peanuts, respectively. Conclusion : The most common cause of accidents was trauma, followed by falls, burns, foreign body aspiration, and poisoning. The incidence of foreign body aspiration and poisoning is increasing in infants. In cases of foreign bodies in airways, proper management is needed because of the high mortality rate.

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.