• Title/Summary/Keyword: 단열 조

Search Result 100, Processing Time 0.024 seconds

Economic Analysis of Insulation Wall Panel System using LCC Method (LCC기법을 활용한 단열외벽패널시스템의 경제성분석)

  • Kim, Min-Woo;Jeon, Kyu-Nam;Lee, Gun-Cheol;Cho, Byoung-Young;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.153-155
    • /
    • 2011
  • In this study, an insulation panel system that has the most excellent economic feasibility in a long term LCC viewpoint in some analysis, which determine a proper insulation panel construction method for the out wall of structures, is analyzed. As a result, in the case of a deterministic LCC analysis, the initial investment cost represents about 80,000Won/㎡ for extrusion ceramic panels. Also, although the costs of maintenance, disassembling, and disposal show no large differences compared with other panel systems, metal panels indicate a bit higher than other panel systems about 1.5 times. In the probability density function that analyzes the variation of the probabilistic cost between panel systems and its economic feasibility, metal panels show the highest cost distribution and extrusion and stone panels represent low cost distributions. In the cumulative function distribution that composites probability density functions, the extrusion ceramic panel represents the most excellent economic feasibility and reliability and that is also the most superior subject among the subjects used in this study.

  • PDF

COMPARISON OF THE EFFECTS OF THERMAL MASS EXTERIOR WALLS ON HEATING AND COOLING LOADS IN COMMERCIAL BUILDINGS - Evaluation of Delta Load Concept Used in The Draft Standard ASHRAE 90. 1 - (상업용 건물에 있어서 외벽의 축열용량이 난방부하에 미치는 영향 연구 - ASHRAE Standard 90. 1안에서 사용된 Delta Load 개념의 평가 -)

  • Park, Sang-Dong;Kusuda, Tamami
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.372-379
    • /
    • 1986
  • 본고는 상업용 건물에 있어서의 냉난방부하에 대한 외벽의 축열(열용량)효과를 비교$\cdot$분석하는데 그 목적이 있다. 가장 최근에 발표된 에너지 해석 프로그램인 DOE-2.1C를 이용하여 Berkeley Solar Group (BSG) 이 제안한 축열효과를 분석하였다. 본 고에서의 축열효과는 "delta load"로서 표현되어 있으며 "delta load"는 전형적인 나무구조 건물과 벽돌조 건물의 연간 냉난방부하의 차이로서 표시된다. BSG 보고서에 의하면 delta load는 (1)구조물의 위치와 관련한 단열방법 (2)벽의 열용량 (3)벽의 열관류을 (4)기후조건에 따라 달라진다고 되어 있다. 본 고에서의 delta load 계산은 중규모 사무소 건물을 대상으로 하였으며 Lake Charles, LA와 Madison, WI 기후 데이터를 사용하였는데 DOE-2.1C 사용에 의한 delta load는 BSG의 결과와 일반적으로 잘 조화가 되는 것으로 나타났으나 외주부의 방향에 따른 dalta load와 난방에 있어서는 다소 큰 차이를 보여 주고 있으며, 외단열과 중간열의 효과는 BSG의 결과와 마찬가지로 비슷하였다.

  • PDF

Analysis of a Groundwater Flow System in Fractured Rock Mass Using the Concept of Hydraulic Compartment (수리영역 개념을 적용한 단열암반의 지하수유동체계 해석)

  • Cho Sung-Il;Kim Chun-Soo;Bae Dae-Seok;Kim Kyung-Su;Song Moo-Young
    • The Journal of Engineering Geology
    • /
    • v.16 no.1 s.47
    • /
    • pp.69-83
    • /
    • 2006
  • This study aims to evaluate a complex groundwater flow system around the underground oil storage caverns using the concept of hydraulic compartment. For the hydrogeological analysis, the hydraulic testing data, the evolution of groundwater levels in 28 surface monitoring boreholes and pressure variation of 95 horizontal and 63 vertical water curtain holes in the caverns were utilized. At the cavern level, the Hydraulic Conductor Domains(fracture zones) are characterized one local major fracture zone(NE-1)and two local fracture zones between the FZ-1 and FZ-2 fracture zones. The Hydraulic Rock Domain(rock mass) is divided into four compartments by the above local fracture zones. Two Hydraulic Rock Domains(A, B) around the FZ-2 zone have a relatively high initial groundwater pressures up to $15kg/cm^2$ and the differences between the upper and lower groundwater levels, measured from the monitoring holes equipped with double completion, are in the range of 10 and 40 m throughout the construction stage, indicating relatively good hydraulic connection between the near surface and bedrock groundwater systems. On the other hand, two Hydraulic Rock Domains(C, D) adjacent to the FZ-1, the groundwater levels in the upper and lower zones are shown a great difference in the maximum of 120 m and the high water levels in the upper groundwater system were not varied during the construction stage. This might be resulted from the very low hydraulic conductivity$(7.2X10^{-10}m/sec)$ in the zone, six times lower than that of Domain C, D. Groundwater recharge rates obtained from the numerical modeling are 2% of the annual mean precipitation(1,356mm/year) for 20 years.

The Heat Transfer Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 열이송 성능)

  • Park, Min Kyu;Lee, Jung Ryun;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.69-69
    • /
    • 2011
  • 태양열 발전 플랜트에 사용되는 중고온 범위의 축열조에 고체-액체간 상변화를 수행하는 용융염을 축열물질로 사용하면 액체상 또는 고체상만으로 된 열저장 매체에 비해 축열조의 규모를 축소함과 동시에 축열온도의 균일성 향상에 기여할 수 있다. 중온인 $250{\sim}400^{\circ}C$ 범위에서 이용 가능한 용융염으로는 질산칼륨($KNO_3$), 질산리튬($LiNO_3$)등이 있다. 그러나 이러한 용융염의 가장 큰 단점은 열전도율이 매우 낮다는 것이며, 이로 인해 요구되는 열전달률을 성취하기 위해서는 많은 열접촉면적이 필요하다는 것이다. 이러한 단점을 극복하는 방법을 도입하지 않고서는 축열시스템의 소규화를 성취하는데 큰 효과를 가져올 수 없다. 한편 열수송 성능이 탁월한 히트파이프를 사용하면 열원 및 열침과 축열물질 사이의 열전달 효율을 증가시켜 시스템의 성능 향상과 동시에 소규모화에 기여할 수 있다. 중온 범위 히트파이프의 작동유체로서 다우섬-A(Dowtherm-A)는 $150^{\circ}C$이상 $400^{\circ}C$까지의 범위에서 소수에 불과한 선택적 대안 중 하나이다. 따라서 본 연구에서는 용융염을 사용하는 중온 태양열축열조에 적용 가능한 다우섬-A 히트파이프의 성능을 파악하여 기술적 자료를 제시하고자 하였다. 열원으로는 고온 고압의 과열증기, 그리고 열침으로는 중온의 포화증기를 고려하였다. 용융염 축열조를 수직으로 관통하는 히트파이프는 하단부에서 열원 증기와 열교환 가능하며, 중앙부에서 축열물질과 열교환하고, 상단부에서는 중온 증기와 접촉할 수 있도록 배치하였다. 축열모드에서는 히트파이프의 하단부가 증발부로 작동하고, 중앙부가 응축부로 작동하여 용융염으로 열을 방출하면 용융염의 온도가 상승하고 용융점에 도달하면 액상으로의 상변화가 진행되면서 축열이 활성화된다. 축열모드에서 히트파이프의 상단부는 단열부로 작동한다. 방열과정에서는 히트파이프의 하단부가 단열된 상태이고, 중앙부는 용융염으로부터 열을 받아 증발부로 작동하며, 상단부는 중온 증기로 열을 방출하므로 응축부로 작동한다. 즉, 축열시스템의 작동모드에 따라 하나의 히트파이프에서 증발부, 응축부, 단열부의 위치가 변하게 된다. 특히, 히트파이프의 중앙 부분이 응축부에서 증발부로 전환될 때에도 작동이 보장되려면 내부 작동유체의 연속적인 재순환이 가능해야 하므로, 일반 히트파이프에서와는 달리 초기 작동액체의 충전량을 증발부 전체의 체적보다 더 많이 과충전해야 한다. 이러한 히트파이프의 성능 파악을 위한 실험에서 고려한 변수들은 열부하, 작동액체의 충전률, 작동온도 등이며, 열수송 성능의 지표로서는 유효열전도율과 열저항을 이용하였다. 중온범위에서 적정한 작동온도를 성취하기 위해 실험에서는 전압 조절기로 열부하를 조절하는 동시에 항온조로 응축부의 냉각수 입구 온도를 제어하였다. 하나의 히트파이프에 대해서 최대 1 kW까지의 열부하에서 냉각수 입구 온도를 $40^{\circ}C$에서 $80^{\circ}C$ 범위로 변화시키면 히트파이프 작동온도를 약 $250^{\circ}C$ 내외로 조절 가능하였다. 히트파이프 작동액체 충전률은 윅구조물의 공극 체적을 기준으로 372%에서 420%까지 변화 시켰다. 실험 결과를 토대로 열저항과 유효 열전도율을 각각 입력 열유속, 작동온도, 작동액체 충전률 등의 함수로 제시했다. 동일한 냉각수 온도에서는 충전률이 높을수록 히트파이프의 작동온도가 감소하였다. 열저항 값의 범위는 최소 $0.12^{\circ}C/W$에서 최대 $0.15^{\circ}C/W$까지로 나타났으며 유효 열전도율의 값은 최소 $7,703W/m{\cdot}K$에서 최대 $8,890W/m{\cdot}K$까지 변화했다. 최소 열저항은 충전률 420%인 경우에 나타났는데 이때의 작동온도는 약 $262^{\circ}C$이었다. 히트파이프의 작동한계로서 드라이아웃(dry-out)은 충전률 372%의 경우에 열부하 950 W에서 발생하였으나, 그 이상의 충전률에서는 열부하 1060 W까지 작동한계 발생이 관찰되지 않았다. 실험 결과 본 연구에서의 히트파이프는 중온 태양열 축열조에 적용되어 개당 약 1 kW의 열부하를 이송하면서 축열물질 및 축방열 대상 유동매체와 열교환을 하는데 사용하는데 충분할 것이라 판단된다.

  • PDF

Applied Petrologic Study of the Daebo Biotite Granites in the mid Gyeonggi Massif (경기육괴 중부에 분포하는 대보 흑운모화강암류의 응용암석학적 연구)

  • Yun, Hyun-Soo;Hong, Sei-Sun;Park, Deok-Won;Lee, Jin-Young
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.263-275
    • /
    • 2012
  • Jurassic Daebo biotite granites, known as one of the main stone resources in the country, are widely and away distributed in the Pocheon and Yangju areas of the mid Gyeonggi massif. The objects of the study are mainly to reveal the unique characteristics of grain size, rock color, mineral composition, physical property and fracture system from the above biotite granites. Biotite granites from the Pocheon area (PG) and Yangju area (YG) are represented by coarse-grained and light gray, and medium to coarse-grained and grayish to light gray, respectively. In modes, main minerals of Qz+Af+Pl (quartz+alkali feldspar+plagioclase) are more increased in the PG, and accessories of biotite are more increased in the YG, which differences can cause the PG more bright light gray than the YG. Specific gravity (SG) shows somewhat more increasing in the YG than the PG. These differences can be caused by more increasing in biotite contents of higher specific gravity compared to the major minerals in the former than the latter. Absorption ratio (AR) and porosity (PR) of the PG and YG show the same values of 0.33 % and 0.86 %, respectively. In the correlations, PR vs SG and AR vs PR show gradually negative and distinctly positive trends, respectively. Compressive strength (CS) and tensile strength (TS) show increasing in the PG (CS: 1,775 $kg/cm^2$, TS: 87 $kg/cm^2$) than the YG (CS: 1,647 $kg/cm^2$, TS: 79 $kg/cm^2$). These strength characteristics could be attributed to the inherent rock textures of them. Abrasive hardness (AH) also shows a little increasing in PG, which can be caused by increase in quartz contents having higher hardness than the other major minerals. Orientations of fracture sets from the PG and YG were compared with those of vertical rift and grain planes in Mesozoic granites of the country. From the overlapped diagram, the distribution pattern between fracture sets and above vertical planes suggests that microcrack systems developed in Mesozoic granites in Korea occur also in the Daebo biotite granite bodies of the mid Gyeonggi massif. From the relation diagram showing the characteristics of fracture patterns for the above two area, PG and YG may have more potentiality for dimension and non-dimension stone resources, respectively.

On the Latest Tectonic Environment Around Northern Part of the Yangsan Fault, Korea (양산단층 북부 일대의 최후기 지구조환경에 대해)

  • Ryoo, Chung-Ryul;Kang, Ji-Hoon;Kang, Hee-Cheol
    • The Journal of the Petrological Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.173-184
    • /
    • 2018
  • Geologic structures related to the latest event in the evolution around Gyeongsang Basin are mainly associated with the Yangsan Fault. In particular, the structures in the northern part of the Yangsan Fault are mainly observed in the region between Bogyeongsa Temple and Danguri. Such structures are also clustered in the vicinity of the Yangsan Fault, exhibiting similar geometric and kinematic patterns. In general, N-S and NE-SW trending fractures and tectonogeomorphic lineament are mainly eastward dipping reverse faults, such that the blocks in the east of the structures moved west or northwest. The reverse faults are segmented by NW trending fractures that accommodate strike-slip movements. The reverse faults and geomorphotectonic lineaments related to the latest event of deformation in the northern part of the Yangsan Fault show a westward convex patterns. We infer that these structures were initially normal faults that formed during a NW-SE extensional environment and were later reactivated during an E-W compressional one. Such a deformation pattern is also well developed around Pohang-Heunghae area based on the tectonogeomorphic analysis, which appears to be closely related to the Pohang Earthquake (15 Nov. 2017), and its development of the surface rupture and highly damaged zones.

Assessment on Thermal Transmission Property of Wall Through a Scaled Model Test (축소모형 실험을 통한 벽체의 열관류 측정)

  • Chang, Yoon-Seong;Kim, Sejong;Shim, Kug-Bo;Lee, Sang-Joon;Han, Yeonjung;Park, Yonggun;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.884-889
    • /
    • 2015
  • Appropriate evaluation of thermal insulation property of structural member and valid control of cooling/heating energy are important for improving building's energy efficiency. The typical heating system of house in Korea is the floor heating one. The radiation heating system is not only appropriate to climate and geographic conditions of Korea, but also advantageous to provide emotional comfort by the warm feeling of floor. Based on living conditions in Korea, scaled models of the wooden house and concrete house were designed. The ceiling was made of styrofoam insulation and the four sided walls and bottom were made of plywood and concrete, respectively. The floor was heated by heating film. Indoor vertical temperature distributions by floor heating system were measured by thermocouple, and surface temperatures on walls were measured by infrared thermography. Also, thermal insulation property of wooden wall was evaluated to build database for improving energy efficiency of wooden building. It is expected that collected data during tests of various types of floor and wall composition could be referenced for evaluating thermal environment of actual conditions of houses.

Relation of Groundwater Flow Rate and Fracture System Associated with Waterway Tunnel Excavation (도수로터널 굴착에 따른 지하수 유출량과 단열의 관련성)

  • 이병대;조병욱;성익환;함세영;이춘오
    • The Journal of Engineering Geology
    • /
    • v.11 no.3
    • /
    • pp.327-337
    • /
    • 2001
  • To verify the characteristics of groundwater inflow accompanied by the tunnel excavation, the flow rate was measured before and after primary grouting. The relationship between the flow rate and fracture system was also analyzed. The initial flow rate was estimated as 120,990 m$^3$/day through six zones, which were characterized by a large amount of inflow before the primary grouting. After the primary grouting, although considerable amount of inflow was still recognized at the six zones, the flow rate was greatly reduced as 42,844 m$^3$/day. However, great recovery of water levels was not observed. Groundwater flow into the tunnel by excavation of the tunnel is mainly controlled by the fracture system that include faults and joints developed in the host rocks. Four sets of discontinuities affecting on the network of grondwater inflow in the study area were identified as follows: N60-85$^{\circ}C$ W.25$^{\circ}$SW/80$^{\circ}$SW(TSet 1), N40-50$^{\circ}$E.85$^{\circ}$SE/85$^{\circ}$NE(TSet 2), N10-20$^{\circ}$E.85$^{\circ}$SE(TSet 3), and N70-80$^{\circ}$E.80SE(TSet 4).

  • PDF

The temperature condition for the mylonitization of the Cheongsan granite, Korea (변형된 청산 화강암의 압쇄암화작용시의 변형온도 - 변형된 청산 화강암의 구조 해석 -)

Dyke Swarms and Fracture System and their Relative Chronology and Tectonic Implications in the Jukbyeon-Bugu Area, Uljin, East Korea (한반도 동부 울진 죽변-부구 지역 암맥군과 단열계의 상대연령과 지구조적 의미)

  • Kim, Chang-Min;Kim, Jong-Sun;Song, Cheol-Woo;Son, Moon;Choi, Sung-Ja
    • The Journal of the Petrological Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.173-189
    • /
    • 2011
  • Basic to acidic dykes and systematic joints are observed pervasively in the Jukbyeon-Bugu area, Uljin, east Korea. In order to classify the dykes and joints and to determine the relative chronology, their geometries, kinematics, and cross-cutting relationships, and the petrography and geochemistry of dykes are synthetically analyzed. Based on the orientations and cross-cutting relationships of 144 dykes (137 basic and 7 acidic dykes) and 370 systematic joints, three basic dike swarms (M-10, M-80, and M-100), one acidic dyke group (AD), and four joint sets (J-10, J-40, J-80, and J-150) are classified. Some of the J-150 joints reactivated as dextral strike-slip fault are recognized in the field and named as F-340R. According to petrographic, geochemical, and occurrence features in the field, M-80 and M-100 dykes have originated from a co-magma and intruded under the same stress field, even though they have intruded through different passages, preexisting fractures and new fractures created by magmatic pressure, respectively. And the relative chronology of dyke swarms and joint sets in the study area is determined as follows : ${\rightarrow}$ ${\rightarrow}$ ${\rightarrow}$ ${\rightarrow}$ ${\rightarrow}$ . And the M-80 (M-100) and M-10 dyke swarms intruded under NNE-SSW and NW-SE trending horizontal minimum stress fields, respectively. According to a synthesis of the results of the previous and this studies, the M-80, M-10, and F-340R are interpreted to have been formed about 64-52 Ma, Eocene~Oligocene, and Miocene, respectively.