• Title/Summary/Keyword: 단열효율

Search Result 206, Processing Time 0.033 seconds

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.

건축물 에너지절약 설계기준 개정에 따른 온돌시스템 기술개발 방향

  • 강재식;이승언
    • 월간 기계설비
    • /
    • s.143
    • /
    • pp.60-74
    • /
    • 2002
  • 건축물의 에너지 이용을 효율화하기 위하여 단열기준 등을 기존보다 20% 이상 강화하는 것을 골자로 하는 건축물의 에너지절약 설계기준(건설교통부 고시 제2001-118호)이 지난해 6월 1일부터 시행되고 있다. 개정 기준의 가장 큰 특징은 단열기준의 적용 부위를 외기에 직접 면한 부위와 간접 면한 부위로 구분하고, 지역을 중부와 남부, 제주도로 구분$\cdot$설정하여 부하조건과 에너지 소비특성에 따라 건축물의 단열기준을 세분화한 것이다. 특히, 종래에는 최하층 바닥에만 적용하였던 거실 바닥(온돌)의 단열기준을 중간층까지 확대$\cdot$적용하였고, 여기에 온돌시스템의 열적 특성을 고려하여 단열기준의 적용 부위를 보다 구체적으로 설정하고 있다. 따라서 종래의 온돌시스템에서 채움층으로 일반적으로 사용하고 있는 현장 타설식 경량기포콘크리트의 열전도율이 0.13W/mK 내외임을 고려한다면 현행 습식온돌시스템의 열관류율은 $1.0W/m^{2}K$ 이상이 될 것으로 예상됨으로서 앞으로 온돌시스템의 배관층 하부에 $1.0m^{2}K/W$ 이상의 열전도저항을 지닌 단열층이 구성되어야만 개정기준에서 정하는 열관류율 $0.81W/m^{2}K$(기준층 기준)의 성능과 배관하부의 열전도저항값 적용비율을 만족할 수 있을 것으로 판단된다.

  • PDF

나노박막 코팅을 통한 단열 창호 구성 및 특성 분석

  • Seo, Mun-Seok;Sin, Gwon-U;Jo, Jin-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.307.2-307.2
    • /
    • 2013
  • 창호를 통해 건축물 내부에 유입되는 태양광, 특히 태양열 유입에 큰 영향을 미치는 적외선 파장대역을 차폐할 수 있는 특성을 갖는 근적외선 반사 또는 흡수용 원천소재 개발하였다. 근적외선 반사는 고 굴절률/저 굴절률 다중 코팅막을 이용하여 상대적으로 에너지가 높은 800~1,300 nm 파장 영역의 근적외선만을 효율적으로 반사시킬 수 있 방식으로 적외선 차단 효율을 개선하였다. 근적외선 흡수용 나노박막 유 무기 복합소재를 기반으로 하여 특정 파장대에서 적외선을 흡수하도록 하여 적외선 차단 효율을 증대시켰다. 본 연구개발의 고단열 유리는 기존에 개발된 저방사 유리의 문제점인 높은 근적외선 투과문제를 해결하기 위한 대체/보완기술로서 이를 이용한 대면적 코팅을 통한 고기능성 복층창호 시스템을 구성하였고, 이에 대한 단열 특성 실험을 실시하였다.

  • PDF

Rational Efficiency of Compression Processes by the Second Law of Thermodynamics (열역학 제2법칙에 의한 압축과정의 합리적 효율)

  • 정평석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1200-1210
    • /
    • 1990
  • Conventional efficiencies of the adiabatic compression process such as isentropic efficiency and polytropic efficiency can be explained as exergetic efficiencies replacing the reference atmospheric temperature with the temperature which can be determined in the process itself. So that, other efficies such as maximum isentropic efficiency can be defined by giving proper reference temperatures. By applying the same logical principles, exergetic and other rational efficiencies for the non-adiabatic compression process are also defined and discussed for their physical meanings and reasonable engineering applications.

진공단열재의 단열성능을 개선을 위한 Glass Fiber 수평 배열(다층구조) 기술 개발

  • Han, Jeong-Pil;Hwang, Seung-Seok;Jeon, Seung-Min;Min, Byeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.207-207
    • /
    • 2012
  • 진공단열재는 폴리우레탄 폼 대비 10배 이상의 단열성능을 갖는 고효율 단열재로서 고차단성 필름 봉투 내부에 무기 소재를 진공감압시켜 대류에 의한 열전달을 최소화시킨 차세대 단열재이다. 특히 진공단열재에 있어 열전달의 경로는 전도에 의한 효과가 가장 크므로, 진공단열재 내부의 Glass Fiber 심재의 최적화 설계에 따라 단열 성능을 극대화 시킬 수 있다. 이에, 본 연구에서 GLass Fiber의 배열에 따른 성능 비교 평가를 통해, 전도의 특성을 최소화 시킬 수 있는 Glass Fiber의 배열 및 다층 적층 구조를 통해 성능 개선 효과를 고찰 하였다.

  • PDF

Design and Performance Analysis of Screw Supercharger (스크류 수퍼차저의 설계 및 성능해석)

  • 박동규;이관수;오박균
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.72-80
    • /
    • 2000
  • This study aims at the optimal design of the screw rotor, its performance analysis, and development of a small screw supercharger which has a low noise compared with the root type supercharger. The basic theoretical equations and the basic design of the screw supercharger have been established. The optical design of the screw rotor's shape has been also performed theoretically. Also, the performance analysis technique of the designed screw rotor has been developed.

  • PDF

A Evaluation Analysis on Thermal Performance of High Airtight and Insulated Window of High Efficiency Energy Equipment (고효율에너지기자재 고기밀성 단열창호의 단열성능 평가 연구)

  • Jang, Cheol-Yong;Bang, Joo-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.227-230
    • /
    • 2009
  • Currently the country's foreign energy dependence reaches approximately 97% and the total energy consumption percentage of buildings(commercial and domestic parts) reaches approximately 24%. Building energy saving by enhanced insulation will be very important issue. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. This research used for commercialization and ills semination by basic information through a evaluation on insulation performance of the window of high efficiency energy equipment which can improve the insulation performance.

  • PDF

RF-Magnetron Sputtering으로 제조된 근적외선 차폐용 나노 박막 소재를 이용한 고투과성 단열창호 연구

  • Kim, Hye-Jin;Lee, Geon-Hui;Seo, Mun-Seok;Han, Jong-Hun;Sin, Gwon-U;Kim, Seon-Min;Jo, Jin-U
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.221-221
    • /
    • 2011
  • 최근, 대외적으로 기후변화협약 등 환경에 대한 관심이 높아지면서 국내에서도 온실가스 배출이 큰 에너지의 22.3%를 소비하고 있는 건축물로 인한 환경부하에 관심이 높아지며 고효율 창호의 필요성이 대두되고 있다. 기존의 Low-E (저방사) 유리는 적외선을 반사시켜 단열 유리로서 겨울철에 유리하지만, 건물 전면에 약 50~95% 창호가 사용되는 office 건물에는 여름철 냉방에너지를 많이 사용하기 때문에 단열뿐만 아니라 일사 차폐가 가능한 근적외선 차폐유리가 필요하다. 따라서 본 연구에서는 기존의 Low-E 유리의 문제점인 근적외선 투과문제를 해결하기 위한 기술로서 근적외선 영역을 선택적으로 차폐할 수 있는 박막코팅 물질(흡수체, 반사체) 및 Low-E 대체용 Themochromic 등 나노 박막을 RF magnetron sputtering으로 제조하여 복층유리 구조로 조합해 UV-visible을 측정하였으며 IR Lamp와 태양광 아래에서 온도변화 실험을 진행하였다. 그 결과, 기존 Low-E 복층유리 대비 본 실험에서 사용한 복층유리의 근적외선 차폐효율이 개선됨을 확인하였다.

  • PDF

A Design of 16-bit Adiabatic Low-Power Microprocessor (단열회로를 이용한 16-bit 저전력 마이크로프로세서의 설계)

  • Shin, Young-Joon;Lee, Byung-Hoon;Lee, Chan-Ho;Moon, Yong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.6
    • /
    • pp.31-38
    • /
    • 2003
  • A 16-bit adiabatic low-power Microprocessor is designed. The processor consists of control block, multi-port register file, program counter, and ALU. An efficient four-phase clock generator is also designed to provide power clocks for adiabatic processor. Adiabatic circuits based on efficient charge recovery logic(ECRL), are designed 0.35,${\mu}{\textrm}{m}$ CMOS technology. Conventional CMOS processor is also designed to compare the energy consumption of microprocessors. Simulation results show that the power consumption of the adiabatic microprocessor is reduced by a factor of 2.9∼3.1 compared to that of conventional CMOS microprocessor.