• Title/Summary/Keyword: 단열(대)

Search Result 162, Processing Time 0.034 seconds

A Study on the Thermal Insulation Performance of Vacuum Insulation Panel Using Dry Processing Glass Fiber Core (건식 유리섬유 심재를 사용한 진공단열재의 단열특성에 관한 연구)

  • Yoo, Chae-Jung;Kim, Min-Cheol;Go, Seong-Seok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.121-128
    • /
    • 2019
  • There is a big move to build zero-energy buildings in the form of passive houses that reduce energy waste worldwide. Korea has set a goal of reducing its greenhouse gas emissions by 37% by 2030 through the activation of green buildings, such as strengthening the energy levels of new buildings and improving the energy efficiency of existing buildings. The use of insulation with high insulation performance is one of the key technologies to realize this, and vacuum insulation is the next generation insulation that blocks the energy flow of the building. In this study, we measured the bonding structure of dry and wet processing glass fiber core materials and compared the insulation performance of vacuum insulation panel. In addition, the insulation performance of vacuum insulation panel was measured according to the thickness of the laminated core. It can be confirmed that the lamination structure of the core and the lamination thickness are important factors for the heat insulating performance of the vacuum insulating panel.

Evaluation of Thermal Insulation and Hypothermia for Development of Life Raft (해상 구명정의 단열성능평가 및 저체온증 예측 수치해석 연구)

  • Hwang, Se-Yun;Jang, Ho-Sang;Kim, Kyung-Woo;Lee, Jang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.485-491
    • /
    • 2015
  • The technology review about risk of hypothermia of victim according to heat transfer characteristic of life raft and sea state can use accident correspondence of standing and sinking of ship. This study studied heat transfer characteristics required for the design of life raft and thermal insulation property analysis and evaluation methods. In addition, it is study for comprehend the risk of hypothermia and suggest analysis result that is experiment of thermal insulation property and body temperature property for decide of prediction the body temperature decline Thermal Analysis apply the finite element analysis method is comprehended the property of heat conductivity, convective effect of sea water and properties changes according to property of insulation material. it measure the heat flux with attach temperature sensor on body in order to comprehend the variation of body temperature with boarding a life raft experiment on a human body. This study validate results by comparing variation of temperature measured from experiment on a body with variation of temperature from finite element analysis model. Also, the criteria of hypothermia was discussed through result of finite element analysis.

Characteristics of Large-Scale Fault Zone and Quaternary Fault Movement in Maegok-dong, Ulsan (울산 매곡동 일대의 대규모 단층대 특성과 제4기 단층운동)

  • Cho, Jin-Hyuck;Kim, Young-Seog;Gwon, Sehyeon;Edwards, Paul;Rezaei, Sowreh;Kim, Taehyung;Lim, Soon-Bok
    • The Journal of Engineering Geology
    • /
    • v.25 no.4
    • /
    • pp.485-498
    • /
    • 2015
  • Structural analysis for a large-scale fault in Maegok-dong, Ulsan, was carried out based on filed-works to investigate the geometric and kinematic characteristics of the fault as well as its Quaternary slip. As results, a series of repeated stratigraphy, minor faults, fracture zones, and deformation band clusters are observed over a distance of about 100 m in the first studied site consisting of sedimentary rocks, which may indicate the damage zone of a large-scale fault in this site. In the second site, mainly composed of granitic clastic rocks, a large-scale thrust fault is expected based on low-angle dipping faults showing branched and/or merged patterns. Age of the last slip on this fault was restrained as after 33,275 ± 355 yr BP based on radiocarbon dating for organic material included in the gouge zone. Dimension of fault damage zone, dominant sense of slip, and age of the slip event associated with the fault suggest that these structures have a close relationship with the Ulsan Fault and/or Yeonil Tectonic Line, which are well-known large-scale neotectonic structural features around the study area. Therefore, it is necessary to study the characteristics of the faults in detail based on structural geology and paleoseismology in order to ensure seismic and geologic stability of the buildings under construction, and to prevent geologic hazards in this area.

Review on the Effectiveness of Apartments According to Insulation Reinforcement of Energy Saving Design Standard - Energy Cost Analysis of Space Heating and Domestic Hot Water - (에너지절약설계기준의 단열 변화에 따른 공동주택 실효성 검토 - 난방 및 급탕에너지 사용금액 분석 -)

  • Kim, Ji-hyeon;Lim, Hee-won;Lee, Hyun-seung;Shin, U-cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.1
    • /
    • pp.173-178
    • /
    • 2020
  • In this study, we analyzed space heating and domestic hot water(DHW) charges from 2017 to 2018 for 151,206 households in 202 apartment complexes built from 1997 to 2016, in order to evaluate the effectiveness of Korea's insulation standards reinforcement. The applied insulation standards were revised three times(in 1987, 2001 and 2010). We used the Anderson-Darling test to review the normality of the space heating and DHW charges. As a result, each p-value was greater than 0.05 and it followed the normal distribution. The annual average space heating charges per unit area of apartments with the 1987 insulation standards were 5,237₩/㎡a in 2017 and 5,328₩/㎡a in 2018. The heating charges with the 2001 standards were 4,827₩/㎡a in 2017 and 4,817₩/㎡a in 2018. Compared to previous standards(1987 standards), heating charges decreased by 7.8% and 9.6%. Also the heating charges with the 2010 standards were 3,683₩/㎡a in 2017 and 3,734₩/㎡a in 2018. Compared to previous standards(2001 standards), heating charges decreased by 24.3% and 21.5%. On the other hand, compared to each previous standards, DHW charges were decreased by 12.2%, 13.6% or increased by 4.6%, 6.9%, which means there's no correlation between insulation standards reinforcement and DHW charges.

An Analysis of the Impact of Design Factors Using a Simulator of LH2 Storage Tank PRV System (시뮬레이터를 이용한 LH2 저장탱크 PRV시스템의 설계요소 영향분석)

  • Chungkeun Chae;Gyeongtae Im;Yonggyu Kim;Seungbeen Chae
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.47-55
    • /
    • 2024
  • More than 100 liquefied hydrogen tanks are expected to be introduced in Korea by 2030. Since liquefied hydrogen is stored in a vacuum insulation structure tank at -253℃, there is a possibility of a major disaster in which the tank bursts if there is a problem with insulation. Therefore, the law stipulates that PRV should be installed as the last bastion. It is important to note that in the case of liquefied hydrogen, it becomes useless if the pressure drop of the pipe is ignored and the capacity is calculated incorrectly. In CGA S-1.3, the pressure drop rate of the PRV inlet and outlet pipes is set to less than 3% and less than 10%, respectively. However, there is an interdependence between the amount of pressure drop and the flow rate of the pipe, making it impossible to calculate these values at once. Therefore, we developed a simulator that calculates the pressure loss rate of PRV system using MATLAB/Simulink and evaluated the sensitivity of the pressure drop rate to design elements.

Bench Scale Performance Test of WGS and $CO_2$ PSA for $H_2$ Recovery from Syn Gas (합성가스로부터 수소회수를 위한 WGS 및 $CO_2$ PSA 성능평가)

  • Jeong, Seong-Jae;Cha, Jae-Jun;Kim, Young-Suk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.206.1-206.1
    • /
    • 2010
  • 폐기물 등을 열분해 가스화한 합성가스로부터 효과적으로 고순도의 수소를 회수하기 위하여 WGS(수성가스전환반응) 및 $CO_2$ 회수 PSA 공정을 적용하였다. 벤치스케일 열교환형 WGS반응기를 개발하여 기존 단열방식에 비하여 단순화한 반응시스템을 구축하였으며 출구 CO농도 4%대를 달성하였다. 또한 3베드로 구성된 벤치스케일의 $CO_2$ PSA운전을 수행한 결과, 2.5barg 흡착 및 진공재생단계를 적용하여 회수되는 $CO_2$의 농도가 95%이상, 회수율 80%이상을 기록하는 효율적인 $CO_2$ 회수공정을 개발하였다. 한편, 흡탈착 모사프로그램인 ADSIM을 통해서도 실험과 비교적 일치한 결과를 얻을 수 있었는데 향후 스케일업 설계자료 확보시 유용할 것으로 판단되었다.

  • PDF

부산시 금정산 주변지역의 수리지질학적 특성 연구

  • 이병대;조병욱;함세영;김경수;성익환;류충렬
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.267-270
    • /
    • 2002
  • 금정터널 굴착 공사의 실시 설계를 위하여 굴착시 발생하게될 터널내로의 지하수 유출과 관련된 수리지질학적 특성을 연구하였다. 단열들에 대한 정보를 얻기 위하여 지표지질조사 및 지질구조조사를 실시하였다. 연구지역의 투수성을 파악하기 위하여 토양의 물리적, 공학적 특성을 규명하였고, 또한 정압주입시험을 실시하였다. 선구조선의 우세방향은 북북동-남남서 방향으로 동래단층 및 동래단층과 관련된 단층군들이 포함된다. 토양시료의 시험결과, 산정된 수리전도도는 2.l9E-05 m/sec ~ 2.11E-04 m/sec 로서 투수성이 빠름 ~ 매우 빠른 범위 값을 갖는 것으로 나타났다. 주입시험에 의해 산정된 수리전도도는 2.28E-10 m/sec ~ 1.49E-06 m/sec 로서 최대값과 최소값은 4 차수(four order)의 차이를 보였다.

  • PDF

Fluidity and Mechanical Properties of Open Cell AZ31 Mg Alloy Foam

  • Yue, Xue-Zheng;Hur, Bo-Young
    • Journal of Korea Foundry Society
    • /
    • v.32 no.3
    • /
    • pp.150-156
    • /
    • 2012
  • 발포금속은 초경량 재료로서 폐기공과 개기공의 두 가지 형태의 구조를 지니고 있으며 폐기공은 내충격성, 흡음성, 단열성의 기능을 지니고 있고, 개기공은 필터, 생체지지대, 촉매재, 열방출재 등으로 사용되고 있다. 개기공발포재는 삼차원 구조모양으로 프리커서를 이용한 압력정밀주조나 기공입자용출법으로 제조하고 있으나 기공의 크기나 셀의 형상, 두께 등을 조절하기에 어려움이 있다. 이를 해결하기 위하여 환경친화적인 펄라이트를 사용하여 목적하는 크기의 그래뉼을 제조한 후, 용융마그네슘합금을 감압주조법으로 주조하여 그래뉼의 크기로 기공율을 조절하고, 주형의 온도와 압력에 따른 유동의 길이를 측정하였다. 그래뉼 직경이 2.3 $mm{\O}$ 일때에 주형의 온도 $300^{\circ}C$ 이상, 압력이 5000 Pa 이상에서 유동길이 6.5 cm 이상을 얻었다.

동남해안지역의 피압단열 대수층에서 조석 분석법을 이용한 수리상수 추정

  • 심병완;정상용;성익환;이병대;조병욱
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.497-500
    • /
    • 2003
  • If ground water levels of a confined fractured rock aquifer fluctuate with sea tides, individual values of hydrogeologic parameters can be determined. Tidal efficiency and time lag are first calculated from the water level data recorded at an observation device situated inland from the sea. The tidal efficiency factor of the aquifer at the seacoast is then determined from the observation in monitoring wells and used to calculate storage coefficient. Tidal efficiency factor and the tidal time lag are utilized to calculate storage coefficient and the results are compared. This method is tested in the southeastern coastal area of Busan, Korea. This is a simple and inexpensive way to test confined aquifer but the analysis should be performed according to the coastal environment.

  • PDF

국내 육계 사업 실태 및 발전 방향

  • 전승기;장경만
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2001.11a
    • /
    • pp.107-109
    • /
    • 2001
  • Survey questionnaires were collected from broiler farmers and analysed in this study to find out ways to respond to the open international chicken trades-chicken marketing plan and market price control. Broiler farm production and management were analyzed and it was found that number of chicken produced per farm was related to systematic and strategic level of farming such as chicken housing, technical problems, and cost of production.

  • PDF