• Title/Summary/Keyword: 단면적 손실

Search Result 162, Processing Time 0.029 seconds

A study on the social cost estimation of the tunnel section enlargement method considering traffic flow (교통흐름을 고려한 터널단면 확대 시공기술의 사회적 손실비용 산정에 관한 연구)

  • Lee, Seung Soo;Kim, Dong-Gyou;Seo, Jong Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.4
    • /
    • pp.487-497
    • /
    • 2015
  • Using existing tunnel for section enlargement and remodeling is being considered as an optimal alternative in order to solve traffic jam in tunnel. The existing method has been performed while blocking the traffic flow. Recently, New enlargement method was developed which can maintain traffic flow during the construction by using protector. It can minimize social loss due to keeping traffic flow. On the other hand, installing and operating protector can cause economic disadvantages. So, social cost estimation considering traffic flow should be considered for relevant economic evaluation of tunnel section enlargement methods. This paper presents the social cost estimation method of tunnel section enlargement methods considering traffic flow. In addition, to compare economic efficiency existing method with new method, suggested method was applied to Maebong Tunnel.

Elasto-Magnetic Sensors-based Cross-sectional Loss Monitoring of Steel Cables (E/M 센서를 이용한 케이블 단면 손실 모니터링)

  • Kim, Ju Won;Park, Seunghee;Lee, Jong Jae;Yim, Jinsuk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.92-92
    • /
    • 2011
  • 최근 건설기술의 발전과 함께 강재 케이블을 이용하는 시설물의 시공이 점점 증가하는 추세이다. 특히 현수교, 사장교와 같은 초장대 교량에 사용되는 케이블은 주거더 및 상판에 의한 하중의 대부분을 지지하는 핵심부재이다. 하지만 이러한 케이블 부재는 부식, 파단 등으로 인한 단면손실이 발생할 수 있고, 이로 인한 손상부의 응력집중으로 인해 시설물 전체의 붕괴로 이어질 수 있는 위험성을 가진다. 따라서 조기에 단면손실을 찾아 사고를 미연에 방지할 수 있는 강재 케이블 비파괴 검사 기술기반의 건전성 모니터링이 필수적이다. 이러한 효율적인 건전성 모니터링을 위해 스마트 센서를 활용한 연구가 활발히 이루어지고 있는데, 그중 대표적인 스마트 센서중 하나인 마그네틱 센서는 높은 신뢰도와 어디에나 적용 가능한 재현성 때문에 구조물 건전성 평가에 적용하기 유용한 기술로 그 적용범위가 선박, 항공등으로 점점 넓어지고 있는 추세이다. 마그네틱 센서는 그 적용대상에 따라 다양한 마그네틱 특성을 활용할 수 있는데, 최근에는 투자율 계측을 통해 케이블의 장력 측정이 가능한 Elasto-Magnetic 센서(E/M 센서)가 개발되었고 그 활용성에 대한 연구가 이뤄지고 있다. 이에 본 연구에서는 E/M 센서를 이용한 강재 케이블 모니터링 기술을 제안하고자 한다. E/M 센서는 본래 케이블의 장력측정을 위해 개발되었지만 본 연구에서는 강재 케이블 부재의 단면손실 검색을 위해 적용하였다. 제안된 기술의 실험적 검증을 위해 E/M 센서를 이용하여 4가지의 다른 직경을 가지는 강봉시편을 E/M 센서헤드의 1차 코일을 통해 자화시키고, 각각의 직경에서 출력전압을 2차 코일을 이용하여 계측하였다. 그 결과 강봉의 직경이 감소함에 따라 출력 전압이 감소함을 보였다. 반복실험을 통해 해상도 및 선형성이 확보되는 최적의 입력전압과 출력전압의 워킹포인트를 선정하였고, 선정된 조건에서 강봉시편을 일정 간격으로 스캔한 결과 단면감소에 따른 선형적인 출력전압 감소와 동시에 단면 변화 지점에서는 추세선에서 크게 벗어난 출력전압 계측값을 나타내었다. 본 실험을 통해 제안된 E/M 센서를 이용한 강재 케이블 모니터링 기술의 유용성 및 적용가능성을 확인할 수 있었다.

  • PDF

Restraint Coefficient of Long-Term Deformation and loss Rate of Pre-Compression for Concrete (콘크리트 장기변형의 구속계수와 선압축력의 손실률)

  • 연정흠;주낙친
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.521-529
    • /
    • 2002
  • A restraint coefficient for creep and dry shrinkage deformation of concrete in a composite section was derived to calculate the residual stress, and an equation for the loss rate of the pre-compression force was proposed. The derived restraint coefficient was computed by using the transformed section properties for the age-adjusted effective modulus of elasticity. The long-term behavior of complicate composite sections could be analyzed easily with the restraint coefficient. The articles of the current design code was examined for PSC and steel composite sections. The dry shrinkage strains of $150 ~ 200$\times$10^{-6}$ for the computations of the statically indeterminate force and the expansion joint could be under-estimated for less restrained sections such as the reinforced concrete. The dry shrinkage strain of $180$\times$10^{-6}$ for the computation of residual stress in the steel composite section was unreasonably less value. The loss rate of 16.3% of the design code for the PSC composite section in this study was conservative for the long-term deformation of the ACI 205 but could not be used safely for that of the Eurocode 2. For pre-compressed concrete slab in the steel composite section, the loss rate of prestressed force with low strength reinforcement was much larger than that with high strength tendon. The loss rate of concrete pre-compression increased, while that of pre-tension decreased due to the restraint of the steel girder.

Numerical Analysis of Fluid Flow in a Regenerative Cooling Passage (재생냉각 유로 내의 유동에 관한 수치해석)

  • 조원국
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2000
  • A computational analysis has been made on fluid flow in a regenerative cooling Passage for a reduced size liquid rocket engine to predict pressure drop and heat transfer rate in it. The contraction/expansion of the cross sectional area of the passage turn out to increases both the pressure loss and the heat transfer rate of the duct. The changes of the cross sectional area near the nozzle throat are effective to protect the throat which suffers from severe thermal load. Also given is the qualitative characteristics of the performance of the regenerative cooling system due to the variation of coolant flow rate.

  • PDF

Evaluation of Fire-induced Damage to Structural Members in Tunnels (화재에 의한 터널구조물 시공재료의 손상 평가)

  • Chang, Soo-Ho;Choi, Soon-Wook;Kwon, Jong-Wook;Bae, Gyu-Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.219-228
    • /
    • 2006
  • In this study, a series of fire tests was carried out to evaluate fire-induced damage to structural members in tunnels. From the tests, the loss amount of concrete materials under the RWS scenario was slightly bigger than under the RABT fire scenario. Especially under the RWS fire scenario where the maximum temperature is over $1,200^{\circ}C$, the loss of concrete materials was mainly induced by melting. Generally, the loss of materials in reinforced concrete was slightly smaller than that in unreinforced concrete. Depending upon an applied fire scenario, fire-induced damage to shotcrete was quite different. From the realtime investigation of a specimen surface by a digital camcorder, it was proved that the material loss under the RABT fire scenario was mainly induced by spalling. However, it was also revealed that although fire-induced damage in the initial heating stage under the RWS was so close to that under the RABT, the material loss under the RWS at the later stage after 50 minutes elapsed since fire initiation was induced not by spalling but by melting.

Flexural Behavior of RC Beam After Completion of Electrochemical Chloride Extraction (전기화학적 염화물 추출 후 철근-콘크리트 보의 휨 거동)

  • Jung Wook Lee;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.484-492
    • /
    • 2023
  • The structural behaviour of concrete beam was examined by the three points bending test after the completion of the electrochemical chloride extraction (ECE), rather than bond strength mostly measured in previous studies. It was found that the flexural rigidity of concrete was lowered by the ECE, but the strength was enhanced in terms of the maximum load.The flexural rigidity, in the linear elastic range, was reduced by the loss of effective cross-section area. In fact, the inertia moment was substantially subjected to 70 % loss of the cross-section by the tensile strain at the condition of the failure. However, a lower rate of the inertia moment reduction was achieved by the ECE, implying the higher resistance to the cracking, but the higher risk of deformation.

A Model for Liquid Circulation Velocity in Airlift Reactors (공기부양반응기 내에서의 액체순환속도를 위한 모델)

  • Keun Ho Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.446-455
    • /
    • 2023
  • A mathematical model for predicting the liquid circulation velocity in an airlift reactor was developed based on the mechanical energy balance of the fluid circulation loop. The model considered the energy loss due to a 90° turn, the energy loss due to friction, and the energy loss due to the change in cross-sectional area at each part of the reactor. The model that separately considered the loss coefficients related to friction, direction change, and cross-sectional area change was able to predict the liquid circulation velocity better than the previous model using lumped parameters. The liquid circulation velocity was measured by the tracer pulse method. Most of our experimental results obtained in external-loop airlift reactors, which had the top and bottom connecting pipes, as well as other investigators' results obtained in various types of airlift reactors, were well predicted by the developed model with an error within 20%. Useful empirical equations for the loss coefficient related to the 90° turn of the circulating fluid were obtained in external and internal-loop airlift reactors and used to predict the liquid circulation velocity.

Experimental Studies on the Effect of Various Design Parameters on Thermal Behaviors of High Strength Concrete Columns under High Temperatures (다양한 설계변수에 따른 고강도 콘크리트 기둥의 열적 거동 분석을 위한 실험 연구)

  • Shin, Yeong-Soo;Park, Jee-Eun;Mun, Ji-Young;Kim, Hee-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.377-384
    • /
    • 2011
  • Although concrete is considered as fire proof materials, high strength concrete shows severe material and structural damages when exposed to fire. To understand such damages in high strength concrete structures, the effects of various design parameters and fire condition on the thermal behaviors of high strength concrete structures are investigated in this study. In order to achieve this goal, fire tests are performed on high strength concrete columns with different fire conditions and design parameters including cross sectional area, cover thickness, and reinforcement alignment. To investigate thermal behaviors, temperature distributions and amount of spalling are measured. In overall, the columns show rapidly increasing inner temperatures between 30~60 mins of the fire tests due to spalling. In detail, the higher temperature distributions are observed from the columns with the larger cross section and less cover thickness. Moreover, among the columns with same reinforcing ratio, larger number of reinforcements with the smaller diameter causes the higher temperature distribution. The findings from the experimental study allow not only understanding of thermal behaviors of high strength concrete columns under fire, but also guidance in revising fire safety design.

An Analysis on Punching Shear of Two-way Void Slab (이방향 중공슬래브-기둥 접합부 뚫림전단성능의 해석적 평가)

  • Lee, Yung Eun;Ryu, Jaeho;Ju, Young Kyu;Kim, Sang Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.32-32
    • /
    • 2011
  • 최근 국내외에서 친환경건축물에 관한 관심이 매우 높아짐으로 인해 콘크리트의 물량을 절감하여 이산화탄소량을 줄이는 중공슬래브는 다양한 형태로 세계적으로 개발이 되고 있는 추세이다. 특히 이방향 중공슬래브는 환경적인 측면에서 이방향 중공슬래브는 중공부 생성에 재생플라스틱을 활용하여 폐자원을 재사용하고, 콘크리트와 철근의 사용량 절감에 따른 화석에너지 및 이산화탄소 발생량을 감소한다는 장점이 있다. 또한 시스템 측면에서 이방향 중공슬래브는 기존의 철근콘크리트 플랫플레이트 바닥구조 시스템의 자중을 절감하여 구조체를 경량화 시키고, 이에 따라 장스팬 구현이 가능하며, 단열효과가 뛰어나다. 이와 같이 이방향 중공슬래브는 장점이 많지만 플랫플레이트 슬래브의 취약점인 뚫림전단 파괴에 주의해야 한다. 이에 본 연구에서는 선행으로 실시된 이방향 중공슬래브-기둥 접합부 뚫림전단 성능평가 실험을 바탕으로 하여 경량체가 이방향 중공슬래브-기둥 접합부 뚫림전단 성능에 미치는 영향을 살펴보기 위해 범용 유한요소해석 프로그램인 ABAQUS를 사용하여 경량체량 및 위치를 주요변수로 한 해석적인 변화를 검토하였다. 본 연구를 통해 경량체가 삽입된 이방향 중공슬래브의 뚫림전단 성능에 대해, 해석결과 경량체 량과 위치에 따라 최대 뚫림전단강도는 기준 실험체에 비해 74.3%, 73%의 강도저하를 나타내는 것으로 알 수 있었다. 이는 실험상의 강도저하 값인 84.1%, 56.4%와 다소 차이가 있으며, 해석에서 중공부 주위의 응력집중 현상이 제대로 반영되지 않은 것으로 판단된다. 또한 이방향 슬래브에 경량체를 삽입 할 경우 경량체가 시작하는 부분에서 응력이 급격히 감소하는 현상이 나타났으며, 이러한 급격한 응력감소는 기둥 주위 위험단면의 변화를 가져오는 것으로 추정된다. 즉, 위험단면의 변화는 기둥으로부터 경량체 사이의 거리에 따라 달라지며, 위험단면 내의 콘크리트 단면 손실은 뚫림전단 강도를 감소시킨다. 본 연구에서는 이방향 중공슬래브의 뚫림전단강도를 산정할 수 있는 근사식을 제안하였으며, 보다 정확한 이방향 중공슬래브의 뚫림전단강도의 산정식을 위해서는 위험단면의 변화와 콘크리트 단면손실로 인한 전단강도 저하의 관계에 대한 추가적인 연구가 필요하다.

  • PDF

중이온가속기 진공도 요구조건에 대한 고찰

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.100.1-100.1
    • /
    • 2015
  • 중이온가속기에서 잔류기체 분자와 가속 이온의 충돌이 발생하면 이온빔 전류의 손실을 야기하는 직접적인 효과 외에 잔류 기체분자 중에서 전리된 이온들이 반발력에 의해 용기 벽에 부딪힐 때 표면에 흡착되어 있던 기체분자들을 충격탈리(stimulated desorption)시킨다. 더 심각한 경우는 산란된 고속 이온이 용기 벽과 충돌하면서 핵반응을 일으켜 방사화 시키거나 벽에서 다량의 기체를 방출시키는 것이다. 최악의 경우에는 고속이온의 에너지에 의해 용기벽이나 부품들이 열적인 손상을 입을 수도 있다. 현재 설계 및 연구개발이 진행중인 기초과학원(IBS) RISP (Rare Isotope Science Project)의 RAON 중이온가속기는 입사기에서 실험영역까지 각 부분의 진공도 조건이 일반적으로 10-8~10-9 mbar 대에 있어서 이온빔 전류의 손실이나 전리 이온들에 의한 충격탈리는 무시할 수도 있지만 고속이온의 기체방출 수율이 ~104 정도로 높은 것을 감안할 때 고속이온의 충격탈리에 의한 압력 증가가 감내할 수준인지 검토할 필요가 있다. 압력증가는 추가적인 손실을 유발하고 이것은 다시 압력을 상승시키는 진공 불안정성(vacuum instability)을 야기할 수 있다는 축면에서 조심하는 것이 좋다고 판단된다. 고속 중이온과 잔류기체 분자와의 충돌에서 이온이 손실되는 반응에는 쿨롬(coulomb) 산란과 전하교환(charge exchange)이 있는데 전자는 후자에 비해 일반적으로 1/10000 가까이 낮아서 무시할 수 있고, 전자 포획(electron capture) 또는 전자 손실(electron loss, 이온의 전리에 해당)로 대별되는 전하교환 반응이 이온 손실을 주도하는 것으로 알려져 있다. 이 연구에서는 다양한 전하교환 반응 단면적을 아우르는 비례칙(scaling law)을 사용하여 대표적인 중이온인 U33+ 및 U79+의 손실 및 잔류 기체의 전리율을 계산하고 충격탈리에 의한 표면방출 및 압력상승을 일차적으로 고려하여 진공도 조건의 타당성을 입증하려고 한다.

  • PDF