• Title/Summary/Keyword: 단면강도

Search Result 1,188, Processing Time 0.023 seconds

Flexural Strength of Composite HSB Hybrid Girders in Positive Moment (HSB 강재 적용 강합성 복합단면 거더 정모멘트부의 휨저항강도)

  • Cho, Eun-Young;Shin, Dong-Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.385-395
    • /
    • 2011
  • The flexural strength of composite HSB hybrid I-girders under positive moment is investigated by the moment-curvature analysis method to evaluate the applicability of the current AASHTO LRFD design specification to such girders. The hybrid girders are assumed to have the top flange and the web fabricated from HSB600 steel and the bottom flange made of HSB800 steel. More than 6,200-composite I-girder sections that satisfy the section proportion limits of AASHTOL RFD specifications are generatedby the random sampling technique to consider a statistically meaningful wide range of section properties. The flexural capacities of the sections are calculated by the nonlinear moment-curvature analysis in which the HSB600 and HSB800 steels are modeled as an elastoplastic, strain-hardening material and the concrete as CEB-FIP model. The effects of ductility ratio and compressive strength of concrete slab on the flexural strength of composite hybrid girders make of HSB steels are analyzed. Numerical results indicated that the current AASHTO-LRFD equation can be used to calculate the flexural strength of composite hybrid girders fabricated from HSB steel.

Finite Element Analyses on Ultimate Compressive Strength of Longitudinally Stiffened Polygonal Sections (종방향 보강재로 보강된 다각형 단면 기둥구조의 극한강도 해석)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.40-40
    • /
    • 2011
  • 현재 일반적으로 활용되고 있는 원통형 쉘구조로 이루어진 타워구조의 대형화가 추진되면서 제작, 운반 편의성, 단면효율성, 경제성 제고를 위해 다각형단면 기둥구조물의 활용이 대두되고 있다. 하지만 다각형 단면 기둥구조의 극한강도에 대한 자료가 충분치 않고 관련 기준이나 지침이 명확히 제시되고 있지 않은 실정이다. 본 연구에서는 원통형 쉘구조물을 다각형구조물로 대체하여 제작될 경우 축방향 압축에 대한 내하력 향상 효과를 수치해석적으로 검토해 보고자 한다. 해석모델은 지름 2m, 두께 20mm인 원형강관 프로토타입 풍력타워 구조를 참고로 하여 이에 내접하도록 결정한 6~12각형 단면 형상으로써 높이 10,000mm인 3차원 기둥모델을 구현하였고 유한요소프로그램인 ABAQUS를 이용하여 해석하였다. 각 subpanel의 중앙에 종방향 보강재를 설치하였을 때 국부좌굴에 대한 내하력 변화를 비교하기 위해 종방향보강재로 보강한 모델을 구성하여 비교 해석을 수행하였다. 종방향 보강재의 제원은 미국 SSRC 제안식을 기준으로 삼았다. 탄성좌굴해석을 통해 탄성좌굴모드 형상을, 비선형비탄성해석을 통해 최종파괴모드 및 극한강도를 얻었다. 보강 전 후의 탄성좌굴 해석 결과로부터 최소모드의 고유치 값을 비교하였다. 각 subpanel 단면 중심부에 한 개의 보강재를 설치한 경우 탄성좌굴강도가 4배 가량 증가하였다. 이로부터, 보강재(n=1) 설치에 따라 유효 폭두께비가 1/2로 감소하는 효과를 확인 할 수 있다. 비선형해석결과로부터 subpanel의 단면중심에 보강재를 설치한 경우 보강재가 위치한 곳에 고정점이 형성되어 이를 중심으로 국부 좌굴모드에 변화가 생기는 것이 확인되었다. 이러한 변화는 다각형 단면 기둥구조의 내하력 성능, 즉 국부좌굴강도에 영향을 준다. 충분한 강성을 갖는 종방향 보강재가 설치된 경우, 극한상태에서도 유효폭두께비가 줄어드는 것과 같은 강도 향상 효과를 확인할 수 있다. 이러한 사실은 각 해석결과 극한강도를 DIN code, Migita와 Fukumoto의 제안식, SSRC 설계제안식 등과의 비교를 통해 확인할 수 있었다.

  • PDF

Stability Analysis of Unsymmetric Tapered Thin-walled Beams (비대칭 선형 변단면을 갖는 박벽 공간 보의 안정성 해석)

  • 김성보;구봉근;한상훈;정경섭
    • Computational Structural Engineering
    • /
    • v.11 no.4
    • /
    • pp.197-207
    • /
    • 1998
  • 전단변형 효과를 무시하는 경우에 비대칭 선형 변단면을 갖는 박벽 공간 보의 안정성 해석을 위한 일반이론을 유도한다. 비대칭 선형 변단면의 임의점을 통과하는 부재축과 단면의 주축의 방향과 무관하고 부재축과 직각을 이루는 두 개의 좌표축을 도입하여 직각좌표계를 정의한다. 정의된 좌표축을 기준으로 유한한 회전각의 2차항을 고려하는 변위장을 도입하여 연속체에 대한 가상일의 원리로부터 탄성변형에너지, 그리고 초기응력에 의한 포텐셜에너지를 유도한다. 이를 이용하여 비대칭 선형 변단면을 갖는 박벽 공간 보의 안정성해석을 위한 평형방정식을 제시한다. 3차 Hermitian 다항식을 변위파라미터의 형상함수로 사용하여 박벽 공간 보의 탄성강도 및 기하강도행렬을 상정할 뿐만 아니라, 단면의 좌표축에 상관없이 임의의 위치에 작용하는 하중에 대한 하중보정강도행렬(load-correction stiffness matrix)을 제시한다. 본 이론 및 방법의 타당성을 검증하기 위하여 수치해석을 수행하고 문헌의 결과 및 쉘요소를 사용한 해석결과와 비교하여 본 이론의 정당성을 입증한다.

  • PDF

Effect of an Opening on Buckling Strength of Polygonal Section Wind Turbine Tower (다각형 단면 풍력타워 좌굴강도에 대한 개구부의 영향)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.163-163
    • /
    • 2011
  • 풍력타워 기둥구조물에는 유지관리 등의 이유로 출입구 역할을 하는 개구부가 존재하게 된다. 다각형 타워구조물에 개구부형상이 존재하게 되면 압축좌굴 강도에 영향이 있을 것으로 예상되지만, 이를 정량적으로 평가하거나 예측하기는 용이하지 않고 간접적으로 판단할 만한 관련 기준이나 지침도 부족한 상태이다. 이에 최병호 등(2011)에서 다룬 다각형 단면 기둥구조물의 하단에 개구부를 형상화한 수치해석 모델을 수립하고 축방향 압축하중을 재하하는 탄성좌굴 해석 및 비선형비탄성해석을 수행하였다. 본 논문에서는 기존 다각형 단면 기둥모델 중에서 6각형 단면모델에 관해 중점적으로 다루고 있다. 다각형 단면 기둥 해석모델은 단순한 다각형 단면 타워구조에 대해서 뿐 만 아니라, 각 subpanel에 종방향 보강재를 둔 모델에 대해서도 추가적으로 검토하였다. 개구부의 형상은 높이 2000mm, 폭 800mm이며 상하부에 만곡부를 둔 형태이다. 수치해석은 3차원 유한요소해석프로그램인 ABAQUS를 이용하여 수행하였으며, 보강방안으로는 일정범위까지의 모듈 subpanel의 판두께를 보강하는 방안과 edge stiffener를 적용하는 방안에 대해서 검토하였다. 각각의 보강방식에 따른 효과를 비교해 보기 위해 개구부가 없는 모델, 단순히 개구부만 설정한 모델, 판두께를 보강한 모델, edge stiffener로 보강한 모델에 대해 비교해석을 수행하였다. 보강재 없는 단순 다각형 타워구조 모델에 대한 해석결과로부터 개구부로 인한 강도저하는 미미한 수준인 것으로 나타났다. 반면, 종방향 보강재가 적용된 6각형 단면 타워구조 모델에서는 개구부로 인한 강도저감이 22.9%로 높게 나타났으며 상당한 영향이 있는 것으로 분석되었다. 또한 개구부 주변의 판두께 보강이나 edge stiffener보강 등으로 상당한 강도향상 효과가 확인되었으나, 개구부로 인해 손실된 강도 수준을 완전히 회복하는 수준에 미치지 못하는 것으로 나타났다. 따라서, 향후 다양한 보강방식에 대한 보다 포괄적인 변수연구를 통해 개구부의 영향 없이 온전한 다각형 단면 타워 구조의 극한강도에 도달되기 위한 보강 조건에 대해 검토될 필요가 있을 것으로 사료된다.

  • PDF

A Study on Inelastic Behavior of Monosymmetric Singly Stepped Beam Subjected to Uniform Load (등분포 하중을 받는 일축대칭 일단 스텝보의 비탄성 거동 특성 고찰)

  • Park, Yi-Seul;Park, Jong-Sub
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.738-740
    • /
    • 2012
  • 최근 변단면 거더의 경제성을 고려하여 장경간 거더 교량과 강골조 구조물에 변단면보의 사용이 증가하고 있으며, 고강도 강의 등장으로 인해 변단면보의 정확한 좌굴 강도의 평가가 매우 중요시 되고 있다. 본 논문에서는 기존에 연구된 탄성 횡-비틀림 좌굴 강도에 관한 연구를 바탕으로하여 별로 비탄성 구간에 비지지 길이가 존재하는 일축대칭 I형 변단면보의 횡-비틀림 좌굴 강도 해석을 실시하였다. 해석에는 유한요소해석프로그램인 ABAQUS(2007)가 사용되었으며, MINITAB(2006)을 이용하여 간편한 설계식을 제안하고 있다. 일단 계단식 단면을 가지는 보에 대하여 고려하였으며, 플랜지 길이 방향 비, 너비방향 비, 두께의 비로 계단식 I형 보를 나타내었다. 집중 하중을 적용시켰으며 비선형 해석을 위해 잔류응력 및 초기변형과 재료비선형을 고려하였다. 본 연구 결과에서 제안된 식은 향후 다양한 하중이 작용하는 비탄성 횡-비틀림 좌굴 강도에 대한 연구에 많은 도움이 될 것이다.

  • PDF

Stiffness matrices for linearly tapered beam elements (선형 변단면 보요소의 강도행렬)

  • 최외호;민경주;이승우
    • Computational Structural Engineering
    • /
    • v.8 no.1
    • /
    • pp.115-122
    • /
    • 1995
  • For the three dimensional analysis of linearly tapered members, the stiffness matrices are derived. Significant improvements of accuracy and efficiency of the analysis are achieved by using the stiffness matrices developed in this study. Results of these analysis are compared with those based upon stepped representation of beam elements in the ANSYS. The stiffness matrices presented in this study can be used for the analysis of tapered and prismatic members.

  • PDF

Experimental study on Characteristics of Secondary Flow in Meandering Channels (사행수로에서 2차류 특성에 관한 실험적 연구)

  • Seo, Il-Won;Lee, Kyu-Whan;Baek, Kyong-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.976-980
    • /
    • 2005
  • 자연하천과 같은 사행수로에서 발생하는 이차류는 흐름 분포를 왜곡시킴으로써, 유사이동, 하상과 제방침식, 하천의 지형변형 등에 매우 큰 영향을 미치게 된다. 또한, 이차류는 주 흐름방향에 수직으로 발생하기 때문에 자연하천에 유입된 오염물의 횡방향 혼합에도 지대한 역할을 한다. 따라서, 본 연구에서는 사행수로에서 이차류의 특성을 정량적으로 분석하고자 중심각이 $120^{\circ}$인 두 개의 만곡부로 이루어진 사행수로에서 실험을 수행하였다. 실험수로는 직사각형 단면과 자연형 단면 두 가지 형태로 제작하였으며, 자연형 단면 하상은 베타함수를 이용하여 제작하였다. 이차류의 정확한 측정을 위해 3차원 유속측정 장치인 micro-ADV를 이용하였다. 실험조건으로는 직사각형 단면과 자연형 단면에서 평균수심과 유량을 달리하여 실험을 총 12회 수행하였다. 실험결과, 직사각형 단면수로에서의 주 흐름의 최대유속선은 수로의 가장 짧은 경로를 따라 발생하였는데, 이는 Shiono와 Muto (1998)의 결과와 일치한다. 자연형 단면 수로에서의 주 흐름은 직사각형 단면 수로에서의 주 흐름 거동과 비슷한 양상을 보였다. 이것은 실제 자연하천 만곡부에서의 주흐름 거동(최대유속선이 최심선을 따라 발생)과는 상이한 결과였다. 그 첫째 원인은 실험수로의 조도가 일반적인 실제하천의 조도를 상사법칙에 맞게 계산한 값보다 작았기 때문이다. 그리고 두 번째 원인은 실험수로의 하폭대 수심비율은 실제하천의 하폭대 수심비율보다 컸기 때문인 것으로 사료된다. 이차류의 정량적인 분석을 위해 각 측정지점별로 횡방향, 수심방향 유속을 그려본 결과, 직사각형 단면에서는 하나의 셀이 존재하는 반면에 자연형 단면에서는 셀이 두개 존재함을 알 수 있었다. 이는 자연하천에서도 발견되는 현상이다. 실제 자연하천에서는 주 셀이 바깥제방 셀보다 큰 형태를 보이지만, 실험수의에서의 셀의 형태는 주 셀보다 바깥제방 셀이 더 크게 발생하는 것으로 밝혀졌다. 이는 앞서 언급한 바와 같이 조도가 작음으로 인한 것으로 판단된다. 이차류 강도를 계산한 결과, 직사각형 단면 수로의 최대값은 두 번째 만곡 유입부지점(U2)에서 가장 크게 나타났으며. 자연형 단면 수로에서 최대값은 두 번째 만곡을 조금 지난 (U4)지점에서 가장 크게 나타났다. 자연형 단면에서는 하폭 대 수심비가 커질수록 이차류강도가 크게 나왔으나, 직사각형 단면에서는 반대로 나왔다. 그리고, 자연형 단면의 이차류 강도는 직사각형 단면보다 크게 나타났다. 특히, 직사각형 단면의 이차류강도는 첫 번째 만곡부분보다 두 번째 만곡부분이 더 크게 나타나는 현상만 보였지만, 자연형 단면의 이차류 강도는 앞서 언급한 특징 외에 만곡부에서 증가하고, 직선부에서 감소하는 주기적인 형태를 보였다.

  • PDF

An Experimental Study on The Fire Resistance Performance of High Strength Concrete Column mixed Fiber-Cocktail in Standard Fire Condition (하이브리드 섬유를 적용한 고강도 내화콘크리트의 단면크기에 따른 내화성능에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Bum-Yean;Min, Byung-Youl;Ahn, Chan-Sol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.170-175
    • /
    • 2011
  • 최근 고강도 콘크리트의 내화성능이 사회적 이슈로 부각되고 국토해양부에서 고강도 콘크리트의 내화성능 관리기준(안)이 고시되면서 국내에서도 고강도 콘크리트의 내화성능을 향상시키기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 유기질 섬유인 폴리프로필렌섬유(PP섬유)와 강섬유를 하이브리드한 Fiber Cocktail를 혼입한 고강도 내화콘크리트 개발을 위한 연구를 수행하였다. PP섬유는 $160^{\circ}C$의 온도에서 용융되어 콘크리트 내부에 미세한 통로를 형성하여 고강도 콘크리트 부재 내의 수증기압 및 공극압을 효과적으로 배출하여 고강도 콘크리트의 폭렬발생을 억제시키는 데 효과적이며, 강섬유는 PP섬유가 용융된 후의 고강도 콘크리트 부재의 균열 발생을 억제하며 외부로부터 침투하는 열기를 차단할 수 있다. 100MPa 고강도 콘크리트의 내화실험을 실시하여 최적단면 조건을 도출하기 위해 철근온도를 분석한 결과, 단면이 커질수록 철근온도는 점차 낮아지는 경향이 나타났으며 $600{\times}600mm$, $800{\times}800mm$ 단면에서 내화성능을 확보할 수 있는 것으로 나타났으며, 이중 경제성을 고려할 경우 $600{\times}600mm$ 단면이 최적단면으로 도출되었다. 또한 도출된 $600{\times}600mm$ 단면에 대해서 철근의 온도를 분석한 결과 PP섬유 $1.5kg/m^3$와 강섬유 $40kg/m^3$를 배합한 Fiber Cocktail이 최적배합비로 나타났다.

  • PDF

Strength Evaluation of Steel Box Beam-to-Column Connections with Axial Load (축방향 하중을 받는 강재 상자단면 보-기둥 접합부의 강도평가)

  • Hwang, Won Sup;Park, Moon Su;Kim, Young Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.117-127
    • /
    • 2007
  • In this study, we evaluate the strength of steel box beam-to-column connections subjected to axial loads in steel frame piers. The T-connection strength was reduced due to the column axial force in the two-story pier structure. To examine this phenomenon, non-linear FEM analysis was carried out and the analytical procedure was verified by comparing it with experimental results. To clarify the effect of the axial force and major design parameters in connection with strength, influence of panel zone width-thickness ratio, sectional area, and axial force was investigated using FEM analysis. Also, the theoretical strength equations were suggested by stress distribution of panel zone. The strength of the T-connection was compared with one of the one-story pier structure connections. As a result, the strength evaluation equations are proposed in consideration of the panel zone width-thickness ratio and sectional area ratio for the T-connections.

Strength Evaluation on Sectional Members of Prefabricated Precast Concrete Arch with Reinforced Joint (보강된 이음부가 적용된 조립식 프리캐스트 콘크리트 아치의 단면 강도 평가)

  • Joo, Sanghoon;Chung, Chulhun;Bae, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1363-1372
    • /
    • 2014
  • In the previous study, the structural performance of proposed precast concrete arch with reinforced joint was evaluated by structural experiment. In this paper, finite element analysis considering both material and contact nonlinearity was carried out on the specimens of the previous study. Based on the result of analysis and experiment, friction coefficient between concrete blocks was determined. To evaluate the strength of sectional member, elastic analysis was carried out on the arch using linear elastic analysis program. The section force was compared with the nominal strength of arch section. It was concluded that the maximum load of all the specimens exceed the nominal strength of arch section. Those results of the strength evaluation were similar to the results of structural experiments. Therefore, it is concluded that the elastic analysis and ultimate strength model can effectively evaluate the strength for the proposed precast concrete arch composed of concrete blocks and reinforced joint in design.