• Title/Summary/Keyword: 단계별 구조식 모형

Search Result 5, Processing Time 0.026 seconds

A Stagewise Approach to Structural Equation Modeling (구조식 모형에 대한 단계적 접근)

  • Lee, Bora;Park, Changsoon
    • The Korean Journal of Applied Statistics
    • /
    • v.28 no.1
    • /
    • pp.61-74
    • /
    • 2015
  • Structural equation modeling (SEM) is a widely used in social sciences such as education, business administration, and psychology. In SEM, the latent variable score is the estimate of the latent variable which cannot be observed directly. This study uses stagewise structural equation modeling(stagewise SEM; SSEM) by partitioning the whole model into several stages. The traditional estimation method minimizes the discrepancy function using the variance-covariance of all observed variables. This method can lead to inappropriate situations where exogenous latent variables may be affected by endogenous latent variables. The SSEM approach can avoid such situations and reduce the complexity of the whole SEM in estimating parameters.

Comparative Study on Determining Highway Routes (도로의 최적노선대 선정방법 비교 연구)

  • Kim, Kwan-Jung;Chang, Myung-Soon
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.159-179
    • /
    • 2006
  • By using the current road design method that is based on the regulation about structure and facilities standard of the road and the route plan guide of a national road and the alignment optimization road design method which is studied in the inside and outside of country, this study operate the route plan of the sample study and compare and analysis the route character, consequently the current design method has local optimization that is formed the plan by the stage and the section. Alignment optimization road design has the system optimal route search. But cost function has limite that caused by construction parameter that is not included in cost function. So we design a road route included cost function in main fields. As a result, we obtain a realistic and economically road route. The alignment optimization road design model has to be made up some problems, like the change of vertical gradient in the tunnel section, though this defects it has a lot of merits as a geometric design tool, especially in the feasibility study and the scheme design.

  • PDF

An Analysis of Behavior and Strength of Cement using Improved Materials by Laboratory Model Test (실내 모형실험에 의한 지반보강 개량체 특성 분석)

  • Oh, Philjin;Park, Minchul;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.7
    • /
    • pp.19-29
    • /
    • 2012
  • For foundation of Port structure, it is essential geotechnical understanding about feature of ground and the geologic formation which is different to terrestrial ground. What is most important is the understanding of soft ground clay, which is much softer than terrestrial ground. To build foundation of a port structure which is mainly gravity based on the special geographical circumstance that is on the sea, the improvement method of foundation should be applied according to soft clay ground features. Therefore, in this study, the behaviors of improved materials with strength were analyzed on the soft clay foundation where suppose to be located the foundation of port structure. The laboratory model test has been conducted in 2 cases with unconfined compression strength of improved materials, 25kPa and 125kPa. Cement, water, and in-situ soft clay were combined at a fixed rate and made a shape of 5cm diameter ${\times}$ 70cm height column. Improved materials were located with replacement ratio(11%, 35% and 61%) in 38cm diameter ${\times}$ 80cm height cylinder. Finally, the stress distribution ratio on the improved materials and clay, settlement was analyzed by applying a load of 10kPa, 30kPa, and 50kPa.

Experimental Study on Helical Turbine Efficiency for Tidal Current Power Plant (조류 발전용 헬리컬 수차의 효율에 대한 실험적 연구)

  • Han, Sang-Hun;Lee, Kwang-Soo;Yum, Ki-Dai;Park, Woo-Sun;Park, Jin-Soon;Yi, Jin-Hak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.530-534
    • /
    • 2006
  • 조류발전은 조류 유속이 빠른 곳에 수차발전기를 설치하여 해수의 운동에너지로부터 전기를 생산하는 발전방식이다. 2001년부터 해양연구원에서는 울돌목의 우수한 조류발전 개발 여건을 바탕으로 조류에너지 실용화 기술을 개발하고 있다. 본 연구에서는 조류발전 시스템에 사용되는 헬리컬 수차의 효율을 현장실험을 바탕으로 판단하고자 하였다. 현장실험을 위하여 지름 2.2 m, 높이 2.5 m의 수차를 제작하고, 울돌목 협수로의 한 쪽 면에 쟈켓구조물을 설치하여 수차를 거치한다. 수차가 회전함에 따라 회전봉에 일정 마찰을 주어 토크와 RPM을 측정하고, 함께 측정된 유속자료를 이용하여 수차를 효율을 산정한다. 유속-수차효율, TSR(수차의 날개속도와 유속의 비)-수차효율의 상관관계로 실험결과를 고찰하였다. 1중 날개 수차인 경우에 유속 1.4에서 2.6 m/s 사이에서 최대효율이 30 - 35 % 정도였고, 2중 날개 수차에 대한 실험에서는 유속 1.4에서 2.6 m/s 사이에서 최대수차효율이 25 - 35 % 사이임을 알 수 있었다. TSR과 최대수차효율의 상관관계는 실험 case별로 조금씩 다르다. 전체적으로 1중 날개의 경우가 최대수차효율에서 2중 날개보다 TSR 값이 조금 큰 경향을 나타냄을 알 수 있다. 이것은 1중 날개가 2중 날개보다 가벼워 좀 더 큰 RPM을 발생시켜서 나타난 현상으로 생각된다. 현재의 실험결과들을 이용하여 TSR과 최대수차효율을 상관관계를 나타내는 모델식을 도출하였다. 현장시험결과를 종합하면, 현장조류발전 시설이 최소 600 kW의 전력이 생산되기 위해서는 지름 3 m, 높이 3.6 m 인 수차 3개가 하나의 축에 설치되어야하는 것으로 계산되었다. 정격유속이 4.8 m/s이고 수차의 지름이 3m 라면, 최적 전력발생시의 RPM은 1중 날개의 경우 79이고 2중 날개의 경우는 63정도임을 추정할 수 있었다.촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 영상수위계는 우물통 등을 이용하는 기존 방법과 비교하여 구조물이 필요 없어 설치 비용이 저렴하고, 영상에 의한 하천 모니터링 기능을 자체적으로 가지고 있기 때문에 효율적이라고 할 수 있다.따른 4개의 평가기준과 26개의 평가속성으로 이루어진 2단계 기술가치평가 모형을 구축하였으며 2개의 개별기술에 대한 시범적용을 실행하였다.하는 것으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였다. 이상의 행태적 측면과 투자성과측면의 실증결과를 통하여 한국주식시장에 있어서 시장수익률을 평균적으로 초과할 수 있는 거래전략은 존재하므로 이러한 전략을 개발 및 활용할 수 있으며, 특히, 한국주식시장에 적합한 거래전략은 반전거래전

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF