• Title/Summary/Keyword: 다중접지

Search Result 76, Processing Time 0.031 seconds

Design of a Doherty Power Amplifier Using the Spiral PBG Structure for Linearity Improvement (나선형 구조의 PBG를 적용한 도허티 전력증폭기의 선형성 개선)

  • Kim, Sun-Young;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.1
    • /
    • pp.115-119
    • /
    • 2008
  • In this paper, the linearity of Doherty power amplifier has been improved by applying a new Photonic Bandgap(PBG) structure on the output of amplifier. The reposed spiral PBG structure is a two-dimensional(2-D) periodic lattice patterned on a dielectric slab that does not require nonplanar fabrication process. This structure has more broad stopband and high suppression performance than the conventional three cell PBG. Also, It has a sharp skirt property. We obtained the 3rd-order intermodulation distortion(IMD3) of -33dBc for CDMA applications with that of maintaining the constant power added efficiency(PAE), the IMD3 performance is improved as much as -8 dB compared with a Doherty power amplifier without PBG structure. Moreover, the physical length of PBG is shortened, therefore the whole amplifier circuit size is considerably reduced.

Numerical Modeling of Very High Frequency Multi Hollow Cathode PECVD (Very High Frequency Multi Hollow Cathode PECVD 장치의 수치모델링)

  • Joo, Jung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.331-340
    • /
    • 2010
  • 3D fluid based numerical modelling is done for a VHF multi hollow cathode array plasma enhanced chemical vapor deposition system. In order to understand the fundamental characteristics of it, Ar plasma is analyzed with a condition of 40 MHz, 100 Vrf and 1 Torr. For hole array of 6 mm diameter and 20 mm inter-hole distance, plasma is well confined within the hole at an electrode gap of 10 mm. The peak plasma density was $5{\times}10^{11}#/cm^3$ at the center of the hole. When the substrate was assumed at ground potential, electron temperature showed a peak at the vicinity of the grounded walls including the substrate and chamber walls. The reaction rate of metastable based two step ionization was 10 times higher than the direct electron impact ionization at this condition. For $H_2$, the spatial localization of discharge is harder to get than Ar due to various pathways of electron impact reactions other than ionization.

다중 전원을 이용한 듀얼 랑뮤어 프루브 시스템을 통한 플라즈마 진단

  • Kim, Hyeok;Lee, U-Hyeon;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.214-215
    • /
    • 2011
  • RF 플라즈마의 경우 일반적인 싱글 랑뮤어 프루브를 사용하여 I-V 파형을 구하는 경우에, 우리는 시평균한 값만을 구할 수 있다. 일반적인 플라즈마 반응 챔버의 구조상, 양 전극의 크기가 다르기 때문에, 시간에 따라 진동하는 플라즈마 포텐셜의 형태는 정확한 사인파의 형태가 아니다. 그렇기 때문에 플라즈마 포텐셜에 따라서 진동하는 데이터를 시평균한 값에는 DC 오프셋 성분이 나타난다. 이러한 DC 오프셋값은 랑뮤어 프루브를 통한 플라즈마 포텐셜 측정시에 오차로 나타난다. 우리는 DC 오프셋에 의한 에러값을 보정하기 위해 멀티 프루브를 사용할 수 있다. 가장 흔하게 쓰이는 듀얼 랑뮤어 프루브의 경우를 살펴보면, 내부의 전원이 플로팅되어 있으며 전압인가를 위한 회로 또한 접지에서 절연되어 있기 때문에, 플라즈마 포텐셜이 시간에 따라 흔들려도 전체적인 전위가 플라즈마 포텐셜과 함께 움직이기 때문에, 앞에서 말한 DC 오프셋에 의한 오차를 줄일 수있다는 장점이 있다. 그러나, 이를 위하여는 회로의 절대적인 플로팅이 필요하지만 실제 듀얼 랑뮤어 프루브의 전원 회로를 구현시에는, 트랜스포머 등을 사용하여 회로를 절연시켜도 회로에 기생적으로 발생하는 콘덴서 성분 때문에 플로팅에 영향을 받을 수 있다. 또한 양극과 음극 사이의 내부 임피던스가 다르게 나타난다. 실제로 기존의 듀얼 랑뮤어를 가지고 RF 플라즈마를 측정할 때에, 듀얼 랑뮤어 프루브의 두 팁 간에 서로 다른 전압-전류 파형이 나타나곤 한다. 이러한 두 팁간의 전압-전류 파형의 차이는 두 팁이 물리적으로 완전히 동일한 구조를 가질 수 없기 때문에 발생 하기도 하지만, 위에서 밝힌 원인에 의해서도 발생한다. 이로 인하여 듀얼 랑뮤어 프루브에 의한 I-V 파형은 이론 상 원점을 대칭으로 한 기함수의 형태이어야 하는데, 실제 측정 결과를 보면 이러한 대칭 형태의 모양을 보기 힘들다. 우리는 이에 이를 보정하기 위하여 위상이 180도 차이가 나는 두 개의 삼각파 발생 전원을 각각 듀얼 랑뮤어 프루브의 양 팁에 인가하여 두 팁 간의 내부 저항과 기생 임피던스 등을 일치시킨 프루브를 디자인하였으며 이 프루브를 이용한 실험에서, 비교적 완벽하게 원점에 대하여 대칭하는 I-V 커브를 구할 수 있었다. 이에 이 논문에서는 새로운 회로와 이 회로로 이루어진 듀얼 랑뮤어 프루브를 사용하여 플라즈마를 진단하는 방법에 대하여 기술한다.

  • PDF

허리통증유발 탈출 수핵의 대용량제거를 위한 플라즈마발생 전극개발에 관한 연구

  • Yun, Seong-Yeong;Jang, Yun-Chang;Kim, Gon-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.241-241
    • /
    • 2011
  • 최근들어 저온플라즈마를 이용한 생물학적 응용분야가 각광을 받고 있다. 특히 전기전도도를 가진 전해질 내에서 형성된 액상 플라즈마는 열손상없이 암, 세균 및 비정상 장기조직의 제거가 가능하다는 점에서 기존 시술들이 가지는 문제를 해결할 수 있다. 허리통증을 유발하는 탈출 수핵을 대용량으로 제거하기위한 플라즈마발생 전극에 관한 연구가 수행되었다. 수핵 분해량을 늘리기 위해서는 플라즈마를 통하여 다량의 수산화기 라디컬을 형성, 수핵표면에 조사해야 한다. 이를 위하여 6개의 텅스텐 전극표면에서 기포를 발생시켜 플라즈마 발생면적을 넓힐 수 있었다. 텅스텐 전극들은 캡톤코딩과 세라믹 스페이서를 통하여 분리되었고, 전극의 후방에는 SUS 재질의 환형 접지전극을 배치하여 6개의 텅스텐 전극표면에서 모두 기포가 발생할 수 있도록 하였다. 시술적용시 플라즈마 및 전극이 가지는 제한 조건은 단백질 변성을 막기위한 섭씨 45도 이하의 온도 상승과 조직에 대한 기계적인 손상 방지를 위한 2.5 mm 이하의 전체 전극 굵기이다. 이를 만족하는 가운데 수산화기 라디컬 형성을 증대할 수 있는 전극의 구조를 결정하기 위하여 1-D 전기 열유체 모델 도입하였다. 모델에서 도출된 기포의 두께를 바탕으로 다중전극간의 거리 조절을 통하여 플라즈마 방전구조를 전극 - 전극 (기포두께${\times}2$ > 전극간 거리)과 전극 - 기포표면 (기포두께${\times}2$ < 전극간 거리)으로 통제하였다. 형성된 플라즈마의 소모전력, 전자 밀도및 수산화기 라디컬의 회전온도를 분석하기 위하여 0.9% 염화나트륨 수용액, 1.6 S/m, 전해질에서 플라즈마 형성를 형성하고 전기신호 및 광학신호를 관측하였다. 전극에 인가된 전압은 340 VRMS이며 운전주파수는 380 kHz이다. 실험 결과, 전극 - 기포표면 방전구조는 전극 -전극 방전구조에 비하여 전해질의 저항역할로 인하여 방전전류가 3.4 Ipp에서 1.6 Ipp로 감소하였으나, 기포표면에서의 물분자의 분해로 인하여 수산화기 라디컬에서의 발광세기는 약 4배 증가하였다. 또한 수산화기의 회전온도 분포상에서도 전극 - 기포표면 방전은 주변 물분자의 열교환으로 인하여 전극 -전극간 방전의 1500K 에 비하여 낮은 400K를 보였다. 이는 전극-기포표면 방전구조의 전극이 낮은 온도의 수산화기를 다량으로 형성할 수 있음을 시사하며, 카데바를 이용한 실험에서 220초에 걸쳐 약 87%의 수핵을 기계적 손상 및 단백질 변형없이 효과적으로 제거함을 확인하였다.

  • PDF

Power Amplifier Design using the Novel PBG Structure for Linearity Improvement and Size Reduction (선형성 개선과 크기 축소를 위한 새로운 PBG 구조를 이용한 전력증폭기 설계)

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.29-34
    • /
    • 2007
  • This paper presents a novel photonic bandgap (PBG) structure for size reduction and linearity improvement in power amplifier. The proposed structure is a two-dimensional (2-D) periodic lattice patterned on a dielectric slab that does not require nonplanar fabrication process. Throughout the experi-mental results, this structure has more broad stopband and high suppression performance than conventional three cell PBG and distorted uniplanar compact-PBG (DUC-PBG). This new PBG structure can be applied with power amplifier for linearity improvement. The 3rd intermodulation distortion (IMD3) of the power amplifier using new PBG structure is -36.16 dBc for (code division multiple access) CDMA applications. Compared with power amplifier without the proposed PBG structure, improved IMD3 is -13.49 dBc.

The Effects of Substrate Temperature on Properties of Carbon Nanotube Films Deposited by RF Plasma CVD (RF Plasma CVD법에 의해 증착된 카본나노튜브(CNT)의 특성에 대한 기판 온도의 영향)

  • Kim, Dong-Sun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.50-55
    • /
    • 2008
  • Carbon Nanotube (CNT) films were deposited with varying deposition temperature by RF plasma CVD on Fe catalysts deposited onto $SiO_2$ films grown thermally on the silicon wafer using $C_2H_2$ and $H_2$ gases. The Fe catalysts on silicon oxide film were made by RF magnetron sputtering. The grounded grid mesh cover on the substrate holder was used for depositing CNT thin films with high purity. The surface morphologies and chemical structure of deposited CNT films were characterized using SEM, Raman, XPS and TEM. It was observed that deposited CNTs films were carbon fiber type having Bamboo-like multiwall structure and CNT film grown at $600^{\circ}C$ was more dense than that at $550^{\circ}C$, but become less dense at $650^{\circ}C$.

PCB Board Impedance Analysis Using Similarity Transform for Transmission Matrix (전송선로행열에 대한 유사변환을 이용한 PCB기판 임피던스 해석)

  • Suh, Young-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.10
    • /
    • pp.2052-2058
    • /
    • 2009
  • As the operating frequency of digital system increases and voltage swing decreases, an accurate and high speed analysis of PCB board becomes very important. Transmission matrix method, which use the multiple products of unit column matrix, is the highest speedy method in PCB board analysis. In this paper a new method to reduce the calculation time of PCB board impedances is proposed. First, in this method the eigenvalue and eigenvectors of the transmission matrix for unit column of PCB are calculated and the transmission matrix for the unit column is transformed using similarity transform to reduce the number of multiplication on the matrix elements. This method using the similarity transform can reduce the calculation time greatly comparing the previous method. The proposed method is applied to the 1.3 inch by 1.9 inch board and shows about 10 times reduction of calculation time. This method can be applied to the PCB design which needs a lots of repetitive calculation of board impedances.

Design of a Internal Loop Antenna for Multi-band Mobile Handset Applications (다중 대역 이동 통신 단말기용 내장형 루프 안테나 설계)

  • Lee Young-Joong;Lee Jin-Sung;Jung Byungwoon;Park Myun-Joo;Lee Byungje
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.917-925
    • /
    • 2005
  • In this paper, the quad-band antenna for mobile handsets is proposed and developed. The operating frequency bands include GSM(880 MHz${\~}$960 MHz), GPS(1,575 MHz$\pm$10 MHz), DCS(1,710 MHz${\~}$l,880MHz), and PCS(1,850 MHz${\~}$l,990 MHz). The proposed antenna consists of a feed line, a shorting post, and a radiating element of the feed loop. The multi-band operation is achieved by using the fundamental and higher resonant modes of the radiating element. Based on analysis of the current distribution on the radiator, the resonant frequency of each mode can be adjusted by adding the different sizes of slots on the radiator. The radiator of the feed loop is designed to be symmetrical so that the energy is symmetrically distributed on the radiator, which results in omni-directional radiation pattern. The ground plane under the radiator is removed in order to improve the bandwidth. The measured impedance bandwidths are $10.1\%$ in GSM band(VSWR<2.5), $26.8\%$ in GPS band, and DCS/US-PCS bands(VSWR<2.5), respectively. The maximum gains on the H-plane of the fabricated antenna are measured about -0.37 dBi${\~}$2.55 dBi for all operating frequency bands.

A Design of Multi-Band Chip Antenna for Mobile Handsets (휴대단말기용 다중 대역 칩 안테나 설계)

  • Cho, In-Ho;Jung, Jin-Woo;Lee, Cheon-Hee;Lee, Yong-Hee;Lee, Hyeon-Jin;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.4
    • /
    • pp.477-483
    • /
    • 2008
  • The paper introduces mobile handset multi-band chip antenna to be used on meander line PIFA structure and parasite patch. The proposed antenna uses an FR-4 substrate. The top layer is consist of meander lines PIFA structure to implement GSM900 and is connected with each rad and meander line on the via-hole for maximize space efficiency. The middle layer is designed with the signal line and gap to implement a DCS and PCS bands, the bottom layer which is added to a parasite patch on the ground can be show an adjust of frequency and impedance character by the connection of the radiators of middle layer and coupling. The fabricated antenna with the dimension of $28{\times}6{\times}4\;mm^3$. The ground plane a dimension of $45{\times}90\;mm$, designed by a commercial software CST simulator. The experimental results show that the bandwidth for(VSWR<3) is 90($875{\sim}965$) MHz in GSM900 band operation and 380($1,670{\sim}2,050$) MHz in DCS, PCS band operation. The maximum gains of antenna are 0.25 dBi, 3.65 dBi and 3.3 dBi at resonance frequencies and it has omni-directional pattern practically.

Application of DC Resistivity Survey from Upper Portion of Concrete and Geostatistical Integrated Analysis (콘크리트 상부에서 전기비저항 탐사 적용 및 지구통계학적 복합 해석)

  • Lee, Heuisoon;Oh, Seokhoon;Chung, Hojoon;Noh, Myounggun;Ji, Yoonsoo;Ahn, Taegyu;Song, Sung-Ho;Yong, Hwan-Ho
    • Journal of the Korean earth science society
    • /
    • v.35 no.1
    • /
    • pp.29-40
    • /
    • 2014
  • A DC resistivity survey was performed to detect anomalies beneath concrete pavement. A set of high conductive media and planar electrodes were used to lessen the effect's a high contact resistance of concrete. Results of the resistivity survey were analyzed and compared with those of other geophysical surveys such as Ground Penetration Radar (GPR), Impulse Response (IR), and Multi-channel Analysis of Surface Waves (MASW), which were carried out in the same location. The results of resistivity survey showed a high resistive distribution in the section of sink and pavement where a pattern of reinforcement was observed through the GPR survey. Also, a comparison of results between the IR and resistivity surveys indicated that the high resistivity was produced by the high dynamic stiffness in the reinforced section. The co-Kriging of both the results of DC resistivity and MASW surveys at the same location showed that an integrated geostatistical analysis is able to give more accurate description on the anomalous subsurface region than can a separate analysis of each geophysical approach. This study suggests that the integrated geostatistical approaches were used for a decision-making process based on the geophysical surveys.