• Title/Summary/Keyword: 다중점화

Search Result 16, Processing Time 0.016 seconds

A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls (경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구)

  • Park, Sang-Min;Choi, Su-Gil;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.14-21
    • /
    • 2020
  • This paper presents the study of a fire risk to the backside of two miniatures of ISO 9705 2/5 using a lightweight partition for indoor space division and reproduction of the ISO 9705 test. An SGP partition, stud partition, glass wool panel, urethane foam panel, sandwich panel, and glass partition were selected as the test specimens, which are frequently used in construction. According to the ISO 9705 test standard, stabilization was achieved using a measuring device that recorded data before the ignition of a burner and continued recording for 120 s thereafter. After ignition was achieved, the power was increased to 300 kW for 600 s and then reduced to 100 kW for 600 s. The specimens were subsequently observed for 180 s, and the fire risk to the backside and the fire pattern of the wall unit were analyzed. Owing to the amount of heat generated by the ignition source, the maximum temperature of the backside was observed to be 67.7 ℃ for the SGP partition, 55.1 ℃ for the stud partition, 52.4 ℃ for the glass wool panel, 727.4 ℃ for the sandwich panel, 561 ℃ for the urethane foam panel, and 630.5 ℃ for the glass partition. In the cases of the sandwich and urethane foam panels, the explosion of flammable gas occurred by virtue of fusion of the interior materials. The reinforced glass was fractured owing to the temperature difference between the heat- and nonheat-responsive parts. Ultimately, the fire risk to the nearby section room was deemed to be high.

Predicting Harvest Date of 'Niitaka' Pear by Using Full Bloom Date and Growing Season Weather (배 '신고'의 만개일 및 생육기 기상을 이용한 수확일 예측)

  • Han, Jeom-Hwa;Son, In-Chang;Choi, In-Myeong;Kim, Seung-Heui;Cho, Jung-Gun;Yun, Seok-Kyu;Kim, Ho-Cheol;Kim, Tae-Choon
    • Horticultural Science & Technology
    • /
    • v.29 no.6
    • /
    • pp.549-554
    • /
    • 2011
  • The effect of full bloom date and growing season weather on harvesting date of 'Niitaka' pear (Pyrus pyrifolia) in Naju province and the model of multiple linear regression for predicting the fruit growing days was studied. Earlier year in full bloom date, the harvesting date tended earlier but fruit growing days tended longer. Mean and coefficient of variation of fruit growing degree days (GDD) accumulated daily mean and maximum temperature at the base of $0^{\circ}C$ from full bloom date to harvesting date was 3,565, 2.9% and 4,463, 2.5%, respectively. Fruit growing days was not correlated with the fruit GDD accumulated daily mean and maximum temperature at the base of $0^{\circ}C$ in each month but highly correlated with GDD accumulated daily meteorological factors at days after full bloom date. Especially, it was highly negatively correlated with GDD accumulated daily mean and maximum temperature at the base of $0^{\circ}C$ from $1^{st}$ day after full bloom to $60^{th}$ day. The determination coefficient ($r^2$) of multiple linear regression model by full bloom date, GDD accumulated daily mean and maximum temperature from $1^{st}$ day after full bloom to $60^{th}$ day for predicting fruit growing days was 0.7212. As a result, the fruit growing days of 'Niitaka' pear in Naju province can predict with 72% accuracy by the model of multiple linear regression.

Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP (Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석)

  • Kim, Myung-Cheol;Kim, Hak-Joong;Park, Kyung-Hwan;Youn, Hae-Kwon;Lee, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.87-94
    • /
    • 2019
  • Through a press release dated July 17, 2018, the Anti-Corruption and Civil Rights Commission recommended that the National Fire Agency develop preventive measures against fire in the "Indoor Archery Ground" and "Room Escape Café" etc., which were originally excluded from the category of "Publicly Used Establishments." This study developed the hierarchy of domains and indicators of measurement for fire risk assessment of the new business of publicly used establishments through the Delphi Method. It analyzed the goodness of fit scores (over 3.00) and secured an average score of 4.25. Using AHP analysis, the ratio of consistency for the domains of measurement of fire risk assessment was found to be 4.0%, which was lower than CR ≤ 0.1 (10%). The consistency of subsequent measurement indicators were distributed in the range of 0.1%~3.6%, and they were identified as being commonly consistent. The indicators of measurement appeared as follows in order of importance and priority: Type of Internal Passage of Establishment and Evacuation Capacity of Exit (0.316), Control of Ignition Source (0.141), Inherent Risk (0.106), Appropriateness and Adaptiveness of Fire Detection System (0.097), Control of Inflammables/Combustibles (0.084), Guides and Facilities helping Evacuation (0.075), Fire Resistant Structure and Finishing Materials (0.060), Compartmentalization and Emergency Exit (0.049), Risk of Fire Expansion (0.046), and Appropriateness and Adaptiveness of Fire Extinguishing Facilities (0.026). The findings of this study are expected to be expansively used as data for future research on the development of fire risk assessment indicators.

Development of Walk-down Performance Procedures for Fire Modeling of Nuclear Power Plants based on Deterministic Fire Protection Requirements (결정론적 화재방호요건을 기반으로 한 원자력발전소 화재모델링 현장실사 수행절차 개발)

  • Moon, Jongseol;Lee, Jaiho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.43-52
    • /
    • 2019
  • A walk-down procedure for fire modeling of nuclear power plants, based on deterministic fire protection requirements, was developed. The walk-down procedure includes checking the locations of safety shutdown equipment and cables that are not correctly indicated on drawings and identifying the existence and location of combustibles and ignition sources. In order to verify the performance of the walk-down procedure developed in this study, a sample of important equipment and cables were selected for hypothetical multiple spurious operation (MSO) scenarios. In addition, the hypothetical fire modeling scenarios were derived from the selected safe shutdown equipment and cables and an actual walk-down was conducted. The plant information collected through the walk-down was compared to the information obtained from the drawings, so that the collected information may be used as input values for the fire modeling.

Dust Explosion Characteristics of Multi-Walled Carbon Nano Tube (다중벽 탄소나노튜브의 분진폭발 특성)

  • Han, In Soo;Lee, Keun Won;Choi, Yi Rac
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.40-47
    • /
    • 2017
  • Dust explosion hazards are always present when combustible dusts are manufactured or handled in the process. However, industries is experiencing difficulty in establishing chemical accident prevention measures because of insufficiency of information on dust explosion characteristics of combustible dust handled in industry. In this study, we investigated experimentally dust explosion characteristics of two kinds of multi-walled carbon nano tubes (MWCNT) different in particle size distribution and examined classification of dust explosion hazardous area for MWCNT manufacturing or handling process by applying the NFPA 499 code. As a result, $P_{max}$, $K_{st}$, LEL, MIE and MIT of MWCNT 1 having $124.2{\mu}m$ median diameter are obtained 6.3 bar, $56bar{\cdot}m/s$, $125g/m^3$, over 1000 mJ, and over $650^{\circ}C$. $P_{max}$, $K_{st}$, LEL, MIE and MIT of MWCNT 2 having $293.5{\mu}m$ median diameter are 6.2 bar, $42bar{\cdot}m/s$, $100g/m^3$, over 1000 mJ, and over $650^{\circ}C$, respectively. MWCNT 1, 2 are not categorized as combustible dust listed in the NFPA 499 Code for classification of dust explosion hazardous area because explosion severity and ignition sensitivity of MWCNT 1, 2 are below 0.35 and 0.01, respectively.

Selection of Main Air Temperature Factors on Annual Variation of Growth and Fruit Characteristics of Persimmon (감나무 생육 및 과실 특성의 연차 변이에 대한 주요 기온 요인 추출)

  • Jeon, Kyung-Soo;Kim, Ho-Cheol;Han, Jeom-Hwa;Kim, Tae-Choon
    • Journal of Bio-Environment Control
    • /
    • v.19 no.3
    • /
    • pp.165-170
    • /
    • 2010
  • This experiment was conducted to select the affected main factors on growth and fruit characteristics of 'Fuyu' persimmon (Diospyros kaki Thunb.) in 25 factors of air temperature factors in Naju. Mean air temperature, cumulative temperature and days for March and April of 25 factors were the highest annual variation. Number of the first and second principal components extracted from 25 air temperature factors were 14 and 3 factors related with mean temperature for annul and April, and cumulative contribution of these was 52.2%. Also the affected years by the first principal components were 1990, 1980 and 1986. Annual standard deviation on leafing, flowering and maturing date were 4.0~6.7 days range, and flowering date and days from leafing to flowering had the highest coefficient of variation. Annual variation of days from flowering to maturing date was affected by greatly mean air temperature and days of cumulative temperature in October, days from March 1 to leafing date was affected by cumulative temperature for growing period, days from leafing to flowering date was affected by mean air temperature in April. Annual variation of fruit weight was affected by mean air temperature for March and October.