• Title/Summary/Keyword: 다중구조물 모델링

Search Result 19, Processing Time 0.025 seconds

Multi-component Topology Optimization Considering Joint Distance (조인트 최소거리를 고려한 다중구조물 위상최적설계 기법)

  • Jun Hwan, Kim;Gil Ho, Yoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.6
    • /
    • pp.343-349
    • /
    • 2022
  • This paper proposes a new topology optimization scheme to determine optimized joints for multi-component models. The joints are modeled as zero-length high-stiffness spring elements. The spring joints are considered as mesh-independent springs based on a joint-element interpolation scheme. This enables the changing of the location of the joints regardless of the connected nodes during optimization. Because the joints are movable, the locations of the optimized joints should be aggregated at several points. In this paper, the novel joint dispersal (JD) constraint to prevent joint clustering is proposed. With the joint dispersal constraint, it is possible to determine the optimized joint location as well as optimized topologies while maintaining the minimum distance between each joint. The mechanical compliance value is considered as the objective function. Several topology optimization examples are solved to demonstrate the effect of the joint dispersal constraint.

Peridynamic Impact Fracture Analysis of Multilayered Glass with Nonlocal Ghost Interlayer Model (비국부 층간 결합 모델을 고려한 다중적층 유리의 페리다이나믹 충돌 파괴 해석)

  • Ha, Youn Doh;An, Tae Sick
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.6
    • /
    • pp.373-380
    • /
    • 2018
  • We present the peridynamic dynamic fracture analysis to solve impact fracturing of multilayered glass impacted by a high-velocity object. In the most practical multilayered glass structures, main layers are glued by thin elastic masking films. Thus, it is difficult and expensive to construct the numerical model for such a multilayered structure. In this paper, we employ efficient numerical modeling of multilayered structures with a nonlocal ghost interlayer model in which ghost particles are distributed between main layers and they are interacting with each other in peridynamic way. We also consider a simple nonlocal contact condition in peridynamic frameworks to solve impact and penetration of the high-velocity impactor to the multilayered structure. Finally we can confirm the fracture capabilities of the method using a multilayered glass model in which 7 glass layers and a single elastic backing layer are affixed by polyvinyl butyral films.

Composite Surface Modeling of Three-Dimensional Structures -Theory and Algorithms- (3차원(次元) 구조물(構造物)의 복합곡면(複合曲面)모델링-이론(理論) 및 알고리즘)

  • Koh, Hyun Moo;Park, Young Ha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.43-52
    • /
    • 1990
  • Theoretical foundation and algorithms are presented of a new surface modeling and pre-processing system for the three-dimensional structures. The modeling method is based on the boundary representation scheme and composed of two hierarchical model structures: curve-network and surface models. The concept of modeling curve as a union of links is introduced to facilitate surface modeling via various transfinite mapping techniques or Coons Patches. Efficiency and novel aspects of the present method are discussed. Finite element mesh genceration and application procedures will be reported in a later paper.

  • PDF

Integrating the Hoek-Brown Failure Criterion into the Holmquist-Johnson-Cook Concrete Material Model to Reflect the Characteristics of Field Rock Mass in LS-DYNA Blast Modeling (LS-DYNA 발파 모델링에서 현장암반의 특성을 반영하기 위한 Hoek-Brown 파괴기준과 Holmquist-Johnson-Cook 콘크리트 재료모델의 접목)

  • Choi, Byung-Hee;Sunwoo, Choon;Jung, Yong-Bok
    • Explosives and Blasting
    • /
    • v.38 no.3
    • /
    • pp.15-29
    • /
    • 2020
  • In this paper the Hoek-Brown (HB) failure criterion is integrated into the Holmquist-Johnson-Cook (HJC) concrete material model to reflect the inherent characteristics of field rock masses in LS-DYNA blast modeling. This is intended to emphasize the distinctive characteristics of field rock masses that usually have many geological discontinuities. The replacement is made only for the static strength part of the HJC material model by using a statistical curve fitting technique, and its procedure is described in detail. An example is also given to illustrate the use of the obtained HJC material model. Computation is performed for a plane strain model of a single-hole blasting on a field limestone by using the combination of the fluid-structure interaction (FSI) technique and the multi-material arbitrary Lagrangian Eulerian (MMALE) method in LS-DYNA.

A Study on Indoor Propagation Modeling using Patch Scattering Model (패치산란모델을 이용한 실내 전파모델링에 관한 연구)

  • 석우찬;김진웅;석재호;임재우;윤영중
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.772-772
    • /
    • 2001
  • In this paper, we proposed the image-based 3D ray-tracing indoor propagation model using patch scattering model which can calculate the scattering phenomenon of the indoor structures. A patch scattering model for modeling indoor structures defines a scattering phenomenon by using RCS(Radar Cross Section) about rectangular patch without complex calculation, for example generating image antennas about each indoor structures. RCS is simply defined as a ratio of scattering power to incident power, and we use bistatic PCS which is simplified numerically by Physical Optics. Also, a simple indoor compensation factor is defined as empirical constant from measured data instead of complex numerical expression because basic patch scattering model cannot include important multipath components, so we san use patch scattering model in indoor environment using indoor compensation factor.

A Study on Indoor Propagation Modeling using Patch Scattering Model (패치산란모델을 이용한 실내 전파모델링에 관한 연구)

  • 석우찬;김진웅;석재호;임재우;윤영중
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.722-733
    • /
    • 2001
  • In this paper, we proposed the image-based 3D ray-tracing indoor propagation model using patch scattering model which can calculate the scattering phenomenon of the indoor structures. A patch scattering model for modeling indoor structures defines a scattering phenomenon by using RCS(Radar Cross Section) about rectangular patch without complex calculation, for example generating image antennas about each indoor structures. RCS is simply defined as a ratio of scattering power to incident power, and we use bistatic PCS which is simplified numerically by Physical Optics. Also, a simple indoor compensation factor is defined as empirical constant from measured data instead of complex numerical expression because basic patch scattering model cannot include important multipath components, so we san use patch scattering model in indoor environment using indoor compensation factor.

  • PDF

Evaluation of Seismic Performance of Takahama Wharf Using Nonlinear Effective Stress Analysis (비선형 유효응력해석을 이용한 Takahama 잔교식 안벽의 내진성능 평가)

  • Tran, Nghiem Xuan;Lee, Jin-sun;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.4
    • /
    • pp.47-56
    • /
    • 2017
  • Aseismic designs of pile-supported wharves are commonly performed utilizing simplified dynamic analyses, such as multi-mode spectral analyses. Simplified analyses can be useful for evaluating the limit state of structures. However, several pile-supported wharves, that have been damaged during past earthquakes, have shown that soil deformation and soil-pile dynamic interaction significantly affect the entire behavior of structures. Such behavior can be captured by performing nonlinear effective stress analyses, which can properly consider the dynamic interactions among the soil-pile-structure. The present study attempts to investigate the earthquake performance of a pile-supported wharf utilizing a three-dimensional numerical method. The damaged pile-supported wharf at the Kobe Port during the Hyogo-ken Nambu earthquake (1995) is selected to verify the applicability of the numerical modeling. Analysis results showed a suitable agreement with the observations on the damaged wharf, and the significant effect of excess pore pressure development and pile-soil dynamic interaction on the seismic performance of the wharf.

Characteristics of Dynamic Wave Propagation in Peridynamic Analysis with Nonlocal Ghost Interlayer (가상 층간 구조 페리다이나믹 해석의 파동 전파 특성 검토)

  • Ha, Youn Doh
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.4
    • /
    • pp.257-263
    • /
    • 2019
  • Multilayered structures include lamination by relatively thick plies and thin interlayers. For efficient peridynamic analysis of dynamic fracturing multilayered structures, the interlayer is modeled using ghost peridynamic particles while the ply is formulated via real peridynamics. With the nonlocal ghost interlayer, one may keep the discretization resolution low for the ply. In this study, the characteristics of dynamic wave propagation through the nonlocal ghost interlayer in peridynamic analysis are investigated. It is observed that the interlayer not only binds adjacent plies, but also significantly influences energy transfer between plies, and thereby their deformation and motion. In addition, near a surface or boundary, peridynamic particles do not have a full nonlocal neighborhoods. This causes the effective material properties near the surface to be different from those in the bulk. Surface correction based on neighborhood volumes is employed. The impact of surface correction on wave propagation in multilayered structures is investigated.

Hybrid Technique for Active Vibration Control of Plate using Piezoceramic Actuators/Sensors (압전 작동기/감지기를 이용한 평판의 혼합형 능동 진동제어 기술)

  • Kim, Yeung-Sik;Lee, Chul;Kim, In-Soo
    • Journal of KSNVE
    • /
    • v.10 no.6
    • /
    • pp.1048-1058
    • /
    • 2000
  • Thipaper presents a methodology to suppress the vibration of thin rectangular plate clamped all edges using piezo-ceramic material as actuators and sensors. Dynamic characteristics of the structure bonded with distributed actuators/sensors are identified by the Multi-Input Multi-Output (MIMO) frequency domain modeling technique based on the experimental data. Hybrid control scheme is adopted and feedback controller is designed by LQG(Linear Quadratic Gaussian). Feedforward controller is adapted by multiple filtered -$x$ LMS(least mean square) algorithm. Experiment result demonstrates the effective reduction of the vibration label for both the transient and persistent external disturbances.

  • PDF

Modelling on the Carbonation Rate Prediction of Non-Transport Underground Infrastructures Using Deep Neural Network (심층신경망을 이용한 비운송 지중구조물의 탄산화속도 예측 모델링)

  • Youn, Byong-Don
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.220-227
    • /
    • 2021
  • PCT (Power Cable Tunnel) and UT (Utility Tunnel), which are non-transport underground infrastructures, are mostly RC (Reinforced Concrete) structures, and their durability decreases due to the deterioration caused by carbonation over time. In particular, since the rate of carbonation varies by use and region, a predictive model based on actual carbonation data is required for individual maintenance. In this study, a carbonation prediction model was developed for non-transport underground infrastructures, such as PCT and UT. A carbonation prediction model was developed using multiple regression analysis and deep neural network techniques based on the actual data obtained from a safety inspection. The structures, region, measurement location, construction method, measurement member, and concrete strength were selected as independent variables to determine the dependent variable carbonation rate coefficient in multiple regression analysis. The adjusted coefficient of determination (Ra2) of the multiple regression model was found to be 0.67. The coefficient of determination (R2) of the model for predicting the carbonation of non-transport underground infrastructures using a deep neural network was 0.82, which was superior to the comparative prediction model. These results are expected to help determine the optimal timing for repair on carbonation and preventive maintenance methodology for PCT and UT.