Development of Diagnosis System for Diaphragm Operated Globe Valve (다이어프램 구동형 글로브 밸브의 진단장비 개발)

  • Yang, Sang-Min;Shin, Sung-Ky
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.975-980
    • /
    • 2007
  • Air-operated valve is one of principal valves that are used to control fluid flow in nuclear power plants. A periodic diagnosis for the safety of power plants is necessary. But there are many difficulties such as economic loss caused by income of high cost devices and a matter hard to deal with users. In this study, we developed the diagnostic system that users of power plants are easy to handle. The diagnostic system is composed of database module, diagnosis test module and analysis module.

Dynamic Modeling and Test of the Air-Operated Valve (공기구동밸브의 동특성 모델링 및 시험)

  • Cho T.D.;Lee H.Y.;Yang S.M.;Yang S.B.;Kwon B.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1808-1811
    • /
    • 2005
  • The prediction of AOV(air-operated valve) performance is normally evaluated by the allowable opening thrust margin for the opening and closing stroke. However, it is not easy to carry out the dynamic test measurement for all the valves in the nuclear power plant due to the safety and operating conditions. The analysis of the available and required thrust for the valve is simulated as an alternate method to turn around this obstacle. The required air pressures to the stem displacement are discussed for differential valve pressure obtained by experiment. The result of the simulation is compared with that of the experiment. SIMULINK in MATLAB was used for the simulation and the results show good agreement with the actual test carried out with Fisher globe valve.

  • PDF

Design and Analysis of Voice Coil Actuator to Drive Fuel Pump in Automobile (자동차 연료펌프 구동용 보이스 코일 전자기 엑츄에이터의 설계 및 해석)

  • Park, Se-Myung;Kim, Jin-Ho;Bai, Cheol-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.234-238
    • /
    • 2010
  • Solenoid diaphragm fuel pump, which to replace mechanical fuel pump system by utilizing cam-shaft driving force, is in the spotlight for being a high efficient green car component. However, there is a drawback in power consumption as a solenoid diaphragm fuel pump only relies on solenoid for its flux needed in reciprocating motion. Therefore, this research proposes permanent magnet type VCM (Voice Coil Motor) fuel pump system to minimized power consumption. Furthermore, the study compares and analyzes power consumption and dynamic performance between the current and the former solenoid diaphragm pump by conducting finite element analysis with the commercial electromagnetic solver, MAXWELL.

Design of Diaphragm for Ultra High Pressure Sensors and Its performance Evaluation Using a PZT Actuated Deformation Tester (초고압 압력센서용 다이어프램 설계 및 PZT 구동 변형시험기를 이용한 성능평가)

  • Yun, Dae Jhoong;Ahn, Jung Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.58-63
    • /
    • 2019
  • This research aims at designing a diaphragm made of SUS316L stainless steel for ultra high pressure sensors and evaluating its performance with a PZT driven deformation tester instead of high pressure chamber testing up to 100 MPa. Finite element method analysis indicates that the optimum thickness of a flat diaphragm is 1.5 mm not only to secure safety of sensors up to 100 MPa but also to enhance displacement measuring sensitivity. For this thickness, the maximum displacement at the center of the diaphragm is $5.3{\mu}m$. The PZT actuator must offer a force of 1,669 N to create a pressure of 100 MPa at the diaphragm surface in order to obtain a displacement of $5.3{\mu}m$. The performance evaluation by the PZT driven tester demonstrates nearly the same results as the same results as the sensors tested in the ultra high pressure chamber.