• Title/Summary/Keyword: 다이어프램식 블로워

Search Result 1, Processing Time 0.018 seconds

A Study on Safety Performance Evaluation of NG Blower for 5 kW Class Stationary Fuel Cell Systems (5 kW급 건물용 연료전지 시스템 연료승압 블로워 안전 성능 평가에 관한 연구)

  • BAEK, JAE-HOON;LEE, EUN-KYUNG;LEE, JUNG-WOON;LEE, SEUNG-KUK;MOON, JONG-SAM;KIM, KYU-HYUNG;PARK, HAN-WOO;KIM, DONG-CHEOL;LEE, JIN-HEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.675-682
    • /
    • 2017
  • New government, the market for stationary fuel cell systems in domestic is expected to expand in line with the policy for expanding new and renewable energy. In order to promote and expand the domestic market for stationary fuel cell systems, it is required to do research and develop for cost reduction and efficiency improvement technologies through the localization of BOP. In this study, the safety performance including the power consumption, flow rate, noise and air-tightness of the domestic fuel booster blower and the foreign fuel booster blower was evaluated and the performance improvement of the domestic blower was confirmed. As a result of the power consumption measurement and the flow rate according to the back pressure of the A company 2nd prototype and B company, the values were 73 W, 27 LPM, and 55 W, 25 LPM. These results are attributed to the improvement of performance through design changes such as CAM angle and diaphragm material.