• Title/Summary/Keyword: 다이아몬드 분석

Search Result 210, Processing Time 0.033 seconds

Effect of Various Surface Treatment Methods on Shear Bond Strength of Orthodontic Brackets to Aged Composite Resin (시효된 복합레진 표면에 다양한 표면 처리 후 부착한 교정용 브라켓의 전단응력)

  • Park, Jongcheol;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.125-133
    • /
    • 2014
  • The purpose of this study was to investigate the effect of various surface treatment methods on the shear bond strength of orthodontic brackets in vitro. Ninety six specimens, 6 mm in diameter and 5 mm in height, were made with composite resin ($Filtek^{TM}$ Z350 XT, 3M ESPE, USA) and treated with an aging procedure. After aging, the specimens were randomly separated in six groups: (1) control with no surface treatment, (2) 37% phosphoric acid gel, (3) 4% hydrofluoric acid gel, (4) sodium bicarbonate particle abrasion, (5) diamond bur, and (6) 1 W carbon dioxide laser for 5s. The metal brackets were bonded to composite surfaces by means of an orthodontic adhesive (Transbond XT, 3M Unitek, USA). Shear bond strength values were evaluated with a universal testing machine (R&B Inc., Korea). Analysis of variance showed a significant difference between the groups. Group 5 had the highest mean shear bond strength (11.9 MPa), followed by group 6 (11.1 MPa). Among the experimental groups, group 2 resulted in the weakest mean shear bond strength (5.22 MPa). The results of this study suggest that the repair shear bond strength of the aged composite resin was acceptable by surface treatment with a carbon dioxide laser.

Importance of Impregnation and Polishing for Backscattered Electron Image Analysis for Cementitious Self-Healing Specimen (시멘트계 자기치유 시편에 대한 반사전자현미경 이미지 분석을 위한 함침과 연마의 중요성)

  • Kim, Dong-Hyun;Kang, Kook-Hee;Bae, Seung-Muk;Lim, Young-Jin;Lee, Seung-Heun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.435-441
    • /
    • 2017
  • Studies on self-healing have currently been diversified and the methods to evaluate the studies have become more diversified as well. Among them, the back-scattered electron (BSE) image acquired through the scanning electron microscope (SEM) is attempted as the means to evaluate the self-healing effect on cracks. In order evaluate by the BSE image, sophisticated pre-processing of specimen is critical and this injected inside the particle, pore and artificial crack of the hardener to stabilize the structure of the newly generated self-healing product and it enables to endure the stress on polishing without deformation. The impregnated specimen smoothen the surface to obtain the BSE image of high resolution that polishing is made for diamond suspension for wet polishing after dry polishing. As a result of evaluating the self-healing product on the impregnated and polished self-healing specimen, the generated product is formed from the surface of the artificial crack and the self-healing substances are confirmed as $Ca(OH)_2$ and C-S-H.

A Study on Anisotropic Compression Behavior of Illite (일라이트의 비등방적 압축특성 연구)

  • Yun, Seohee;Lee, Yongjae
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.33 no.1
    • /
    • pp.11-18
    • /
    • 2020
  • High-pressure synchrotron X-ray powder diffraction experiments were performed on natural illite (K0.65Al2(Al0.65Si3.35)O10(OH)2) using diamond anvil cell (DAC) under two different pressure transmitting media (PTM), i.e., water and ME41 (methanol:ethanol = 4:1 by volume). When using water as PTM, occasional heating was applied up to about 250℃ while reaching pressure up to 2.7 GPa in order to promote both hydrostatic conditions and intercalation of water molecules into the layer. When using ME41, pressure was reached up to 6.9 GPa at room temperature. Under these conditions, illite did not show any expansion of interlayer distance or phase transitions. Pressure-volume data were used to derive bulk moduli (K0) of 45(3) GPa under water and 51(3) GPa under ME41 PTM. indicating no difference in compressibility within the analytical error. Linear compressibilities were then calculated to be βa = 0.0025, βb = 0.0029, βc = 0.0144 under ME41 PTM showing the c-axis is ca. six times more compressible than a- and b-axes. These elastic behaviors of illite were compared to muscovite, one of its structural analogues.

Synthesis of High-Quality Monolayer Graphene on Copper foil by Chemical Vapor Deposition

  • Lee, Su-Il;Kim, Yu-Seok;Song, U-Seok;Jo, Ju-Mi;Kim, Seong-Hwan;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.351-352
    • /
    • 2011
  • 그래핀(Graphene)은 2차원 평면구조의 $sp^2$ 탄소 결합으로 이루어진 물질이다. 일반적으로 그래핀은 탄소 원자 한층 정도의 얇은 두께를 가지면서 강철의 100배 이상 높은 강도, 다이아몬드보다 2배 이상 뛰어난 열 전도성, 그리고 규소보다 100배 이상 빠른 전자이동도 등의 매우 우수한 특성을 지닌다. 그래핀을 합성하거나 얻는 방법에는, 기계적 박리법(Micro mechanical exfoliation), 산화흑연(graphite oxide)을 이용한 reduced graphene oxide(RGO)방법과 탄화 규소(SiC)를 이용한 epitaxial growth 방법 등이 있지만, 대 면적화가 어렵거나 구조적 결함이 큰 문제점이 있다. 반면, 탄화수소(hydrocarbon)를 탄소 공급원으로 하는 열화학 기상 증착법(Thermal chemical vapor deposition, TCVD)은 구조적 결함이 상대적으로 적으면서 대 면적화가 가능하다는 이점 때문에 최근 가장 많이 이용되고 있는 방법이다. TCVD를 이용, 니켈, 몰리브덴, 금, 코발트 등의 금속에서 그래핀 합성연구가 보고되었지만, 대부분 수 층(fewlayer)의 그래핀이 합성되었다. 하지만, 구리 촉매를 이용하는 것이 단층 그래핀 합성에 매우 효율적이라는 연구결과가 보고되었다. 구리의 경우, 낮은 탄소융해도(solubility of carbon) 때문에 표면에서 self limiting 과정을 통하여 단층 그래핀이 합성된다. 그러나 단층 그래핀 일지라도 면저항(sheet resistance)이 매우 높고, 이론적 계산값에 비해 전자이동도(electron mobility)가 낮게 측정된다. 이러한 원인은 구조적 결함에서 기인된 것으로써 산업으로의 응용을 어렵게 만들기 때문에 양질의 단층 그래핀 합성연구는 필수적이다[1,2]. 본 연구에서는 TCVD를 이용하여 구리 포일(25 ${\mu}m$, Alfa Aeser) 위에 메탄가스를 탄소공급원으로 하여 수소를 함께 주입하고, 메탄가스의 양과 합성시간, 열처리 시간을 조절하면서 균일한 단층 그래핀을 합성하였다. 합성된 그래핀을 $SiO_2$ (300 nm)기판위에 전사(transfer)후 라만 분광법(raman spectroscopy)과 광학 현미경(optical microscope)을 통하여 분석하였다. 그 결과, 열처리 시간이 증가할수록 촉매로 사용된 구리 포일의 grain size가 커짐을 확인하였으며, 구리 포일 위에 합성된 그래핀의 grain size는, 구리 포일의 grain size에 의존하여 커짐을 확인하였다. 또한 동일한 grain 내의 그래핀은 균일한 층으로 합성되었다. 이는 기계적 박리법, RGO 방법, epitaxial growth 방법으로 얻은 그래핀과 비교하여 매우 뛰어난 결정성을 지님이 확인되었다. 본 연구를 통하여 면적이 넓으면서도 결정성이 매우 뛰어난 양질의 단층 그래핀 합성 방법을 확립하였다.

  • PDF

The Thermal and Mechanical Properties of Epoxy Composites Including Boron Carbide Surface Treated with Iron Oxide and Tungsten (철산화물과 텅스텐으로 표면 처리된 보론카바이드를 포함하는 에폭시 조성물의 열적·기계적 물성)

  • Kim, Taehee;Lee, Wonjoo;Seo, Bongkuk;Lim, Choong-Sun
    • Journal of Adhesion and Interface
    • /
    • v.19 no.3
    • /
    • pp.113-117
    • /
    • 2018
  • Boron carbide is lower in hardness than diamond or boron nitride but has a hardness of more than 30 GPa and is used for manufacturing tank armors and ammo shells due to its high hardness. It is also used as a neutron absorber due to its ability to absorb neutrons, which is increasing its use in nuclear power projects. Neutrons have no interaction with electrons and are known to pass through the material without interactions. Along with boron carbide, the atoms with high interaction with neutrons are hydrogen, and high hydrogen concentration polyesters and epoxy polymers including boron are used as materials for manufacturing products for nuclear power generation waste. In this paper, the surface of boron carbide is treated with iron oxide and tungsten to improve interaction between modified boron carbide and epoxy polymer. XRD and XPS were used to confirm that iron oxide and tungsten are well attached on the surface of boron carbide, respectively. The mechanical strength of the surface treated boron carbide was measured by a universal testing machine (UTM) and the dynamic characteristics of the cured product were observed by using a dynamic analyzer (DMA).

High Pressure Behavior Study of the Apophyllite (KF) (고압 하에서 어안석(KF)의 거동 연구)

  • Kim, Young-Ho;Choi, Jinwon;Heo, Sohee;Jeong, Nangyeong;Hwang, Gil Chan
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.325-332
    • /
    • 2015
  • Apophyllite (KF)($K_{0.84}Ca_{3.99}Si_{7.70}O_{20}F_{0.72}{\cdot}8H_2O$), one of the sheet silicates, was compressed up to 7.7 GPa at ambient temperature and 15 high pressure data were obtained. Lattice parameters of the starting specimen were as follows: $a_0=8.954(2)\;{\AA}$, $c_0=15.795(2)\;{\AA}$, $V_0=1266.4(4)\;{\AA}^3$. Symmetrical diamond anvil cell was employed with synchrotron radiation in the mode of angular dispersive X-ray diffraction. Bulk modulus was determined to be 59(4) GPa when ${K_0}^{\prime}$ is 4. No clear first order phase transition symptom was observed in the series of XRD pattern. However, second-order phase transition cannot be ruled out from the correlation between normalized pressure and strain.

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF

A Study of Radon Reduction using Panel-type Activated Carbon (판재형 활성탄을 이용한 라돈 저감 연구)

  • Choi, Il-Hong;Kang, Sang-Sik;Jun, Jae-Hoon;Yang, Seung-Woo;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.297-302
    • /
    • 2017
  • Recently, building materials and air purification filters with eco-friendly charcoal are actively studying to reduce the concentration of radon gas in indoor air. In this study, radon reduction performance was assessed by designing and producing new panel-type activated carbon filter that can be handled more efficiently than conventional charcoal filters, which can reduce radon gas. For the fabrication of our panel-type activated carbon filter, first the pressed molding product after mixing activated carbon powder and polyurethane. Then, through diamond cutting, the activated carbon filter of 2 mm, 4 mm and 6 mm thickness were fabricated. To investigate the physical characteristics of the fabricated activated carbon filter, a surface area and flexural strength measurement was performed. In addition, to evaluate the reduction performance of radon gas in indoor, the radon concentration of before and after the filter passes from a constant amount of air flow using three acrylic chambers was measured, respectively. As a result, the surface area of the fabricated activated carbon was approximately $1,008m^2/g$ showing similar value to conventional products. Also, the flexural load was found to have three times higher value than the gypsum board with 435 N. Finally, the radon reduction efficiency from indoor gas improved as the thickness of the activated carbon increases, resulting in an excellent radon removal rate of more than 90 % in the 6 mm thick filter. From the experimental results, the panel-type activated carbon is considered to be available as an eco-friendly building material to reduce radon gas in an enclosed indoor environment.

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF