• Title/Summary/Keyword: 다수 화염

Search Result 24, Processing Time 0.021 seconds

The Stability of Turbulent nonpremixed interacting Flames (다수노즐에 의한 확산화염의 안정성 확대에 관한 연구)

  • Kim, Jin-Hyun;Lee, Byeong-Jun
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.201-207
    • /
    • 2003
  • Characteristic of turbulent nonpremixed interacting flames are investigated experimentally 8 or 9 nozzles are arranged in the shape of matrix or circle. When there is no center nozzle, flame is more stable than with center nozzle case. It is shown that these blowout limit enlargements are related with the recirculation of burnt gases. The interacting flame base was not located at the stoichiometric point. NO concentrations of interacting flame are smaller than that of single flame using same area nozzle.

  • PDF

Basic Study on Flame-Stabilization Characteristics in a Multi-Channel Combustor via a Model of a Porous-Media Combustor (다공성 연소기 모델로서의 다중 채널 연소기 내부 화염의 안정화 특성 기초 연구)

  • Park, Seung-Il;Lee, Min-Jung;Kim, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.815-823
    • /
    • 2011
  • Combustion phenomena in porous media combustors are widely used in industrial fields for the combustion of lowgrade fuels and the regeneration of combustion heat. However, studies of combustion phenomena in porous media have been limited, because these phenomena are difficult to observe, and the configurations of porous media are complex. We propose a simple model combustor: a multi-channel combustor that consists of many layers of combustion channels made of quartz plates. We conducted an experimental observation of the flames in the multi-channel combustor and obtained experimental results for the flame stabilization limits. Flames formulated in the multi-channel combustor showed variation in the spatial distribution depending on the heat transfer between neighboring channels. A simple analytical model was developed and the variation in the flammability limits of the multi-channel combustor was discussed. This study will enhance our understanding of flame behavior in a porous-media combustor.

The Stability of Turbulent Interacting Flames (다수 난류 비예혼합 화염의 상호작용에 관한 연구)

  • Kim, Jin-Sun;Lee, Byeong-Jun
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.453-458
    • /
    • 2001
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes which depend on the existence of the center nozzles. Six nozzle arrangements which are cross 4, 5, 8, 9, square 8 and circular 8 nozzles are used for the experiment. Those are arranged to see the effect of the center nozzle out of multi-nozzle. There are many parameters that affect flame stability in multi-nozzle flame such as nozzle separation distance, fuel flowrates and nozzle configuration, but the most important factor is the existence of nozzles in the center area from the nozzle arrangement. As the number of nozzle in the area is reduced, more air can be entrained into the center of flame base and then tag flame is formed. In the case of circular 8 nozzles, blowout flowrates are above 5.4 times compared with that of single equivalent area nozzle.

  • PDF

Stability Enhancement by the Interaction of Diffusion Flames (다수 비예혼합 화염의 안정화 특성)

  • Kim, Jin-Sun;Lee, Byeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1420-1426
    • /
    • 2003
  • The stability of turbulent nonpremixed interacting flames is investigated in terms of nozzle configuration shapes and kind of fuels. Four nozzle arrangements - cross 5, matrix 8, matrix 9 and circle 8 nozzles - are used in the experiment. There are many parameters affecting flame stability in multi-nozzle flames such as nozzle separation distance, fuel flowrates and nozzle configuration etc. Key factors to enhance blowout limit are the nozzle configuration and the existence of center nozzle. Even nozzle exit velocity equal 204 m/s, flame is not extinguished when there is not a center nozzle and s/d=15.3∼27.6 in matrix-8 and circular-8 configurations. At these conditions, recirculation of burnt gas is related with stability augmentation. Fuel mole fraction measurements using laser induced fluorescence reveal lifted flame base is not located at the stoichiometric contour.

The Analysis and Comparison of Fire Test for the High Pressure Composite Cylinder by Type (고압복합재용기 Type에 따른 화염시험 비교 분석)

  • Kim, Chang Jong;Lee, Seung Hoon;Lyu, Geun Jun;Kim, Young Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.98.1-98.1
    • /
    • 2011
  • 전 세계적으로 대표적인 대중교통으로 천연가스버스가 운행 중에 있으며, 천연가스의 저장을 위하여 대부분의 차량이 복합용기를 사용하고 있다. 또한 친환경자동차로 개발되고 있는 수소연료전지자동차도 수소 저장용으로 복합용기를 적용하여 상용화를 추진 중에 있다. 복합용기의 상용화가 증가하면서 복합용기의 안전성 확보가 가장 중요한 이슈가 되고 있다. 기체상태의 고압가스를 교통수단에 적용하기 위하여, 저장매체인 고압복합용기의 안전성 및 기술 확보를 위한 기술개발과 안전기준의 확립을 위한 기준개발이 미국, 유럽, 일본 등 다수의 국가에서 진행되고 있다. 현재 복합용기의 안전성을 확인하는 기준은 각 나라의 기준에 따라 진행되고 있으며 천연가스자동차용 저장용기 국제표준으로는 ISO 11439가 적용되고 있다. 수소연료전지자동차용 수소용기의 안전기준은 아직 확립되지 않은 상태이며, 개발된 초안으로는 국제규정으로 UN ECE R No.79 및 국제기술표준으로 ISO/TS 15869가 있다. 개발 중인 국제기준 및 국내기준에서 가장 취약한 부분이 화염시험이다. 화염시험은 자동차에 화재가 발생했을 경우 용기의 폭발을 막기 위하여 안전밸브가 정상적으로 작동하는 지를 확인하는 시험이다. 하지만 현재의 시험방법으로는 자동차에서 발생하는 국부적인 화염에 대한 안전성을 확인하기가 어려운 실정이다. 본 연구에서는 국내의 화염시험기준을 개발하기 위해 수행된 화염시험에 대한 결과와 화염시험장치를 제안하고자 한다.

  • PDF

Effect of Flame Interaction on the NO Emission (다수 상호작용 화염의 공해배출물 특성)

  • Kim Jin Hyun;Lee Byeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.730-736
    • /
    • 2005
  • It has been reported that the interacting multiple jet flames of propane fuel are not extinguished even at the choking velocity at the nozzle exit if eight small nozzles are arranged along the imaginary circle of $40{\sim}72$ times the diameter of single nozzle. In this research, experiments were conducted to know the NO and CO emission characteristics of the interacting flames. Measurements along the centerline of the flame revealed that decrease in CO concentration was followed by the NO decrease and $O_2$ increase. It was found that interacting flame emitted less NO than that of similar area single jet flame. Also, NO emission of partially premixed interacting flame was decreased up to $17\%$ of that of non-premixed multiple jet flame. Though the mechanism of the NO reduction was not clear from this experiment, it's been shown that partially premixed multiple jet flames could be used to achieve clean and highly stable combustion.

Current Research Status on Flame Response Characteristics to Flow Disturbances (유동섭동에 대한 화염응답 특성의 실험적 연구동향)

  • Seo, Seonghyeon;Park, Yongjin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.5
    • /
    • pp.87-94
    • /
    • 2014
  • It becomes critical to understand an energy coupling mechanism between flow perturbations and combustion heat release rate fluctuations for the understanding of high-frequency combustion instabilities occurring in high-performance combustion/propulsion systems. A significant amount of experimental researches have been carried out to understand flame dynamic characteristics by use of flame transfer functions with artificial flow disturbances. Among them, there exist substantial studies on flame response by the excitation of inlet flow. Recently, experimental studies simulating transversal modes excited in actual combustion systems are under way.

Nozzle configurations for partially premixed interacting jet flame to enhance blowout limits (다수 부분 예혼합 화염의 화염날림 유속 확대)

  • Lee, Byeong-Jun;Kim, Jin-Hyun
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.79-84
    • /
    • 2004
  • For the non-premixed interacting jet flames, it has been reported that if eight small nozzles are arranged along the circle of 40 $^{\sim}$ 72 times the diameter of single jet, the flames are not extinguished over 2oom/s. In this research, experiments were extended to the partially premixed cases to reduce both flame temperature and NOx emission. Nine nozzles were used- eight was evenly located along the perimeter of the imaginary circle and one at the geometric centre. The space between nozzles, S, the equivalence ratio, ${\Phi}$, the exit velocity and the role of the jet from the centre nozzle were considered. Normally, flame was lifted and flame base was located inside the imaginary circle made by the nozzle. As nozzles went away from each other, blowout velocity increased and then decreased. The maximum blowout velocity diminished with the addition of air to the fuel stream. When the fuel and/or oxidizer were not fed through the centre nozzle, the maximum blowout velocity obtained by varying Sand ${\Phi}$ was around 160m/s. Optimum nozzle separation distance at which peak blowout velocity obtained also decreased with ${\Phi}$ decrease. Flame base became leaner as approaching to the blowout. It seemed that lots of air was supplied to the flame stabilizing region by the entrainment and partially premixing. To approve this idea and to enhance the blowout velocity, fuel was supplied to the centre region. With the small amount of fuel through the centre nozzle, partially premixed flame could be sustained till sonic velocities. It seemed that the stabilizing mechanism in partially premixed interacting flame was different from that of non-premixed case because one was stabilized by the fuel supply through the centre nozzle but the other destabilized.

  • PDF

Analysis of Vertical Combustion and Carbonization Patterns of Floor Materials When Using a Needle Flame (니들 플레임에 의한 바닥재의 수직 연소 및 탄화 패턴의 해석에 관한 연구)

  • Park, Min-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.101-106
    • /
    • 2020
  • This study analyzed flame growth characteristics and carbonization patterns when floor materials were burned vertically using a needle flame produced for this study. It was found that PVC flooring was fire retardant and the area under direct flame contracted inward. Vertical combustion causes solidification in the form of a lump at the bottom and also generates soot in a pattern that progresses upwards. This study found that laminated flooring exhibited no fire retarding characteristics and that the laminated layer of its upper surface was destroyed by fire, causing irregular delamination. The carbonization ranges at the left and right sides were determined to be symmetrical. A vertical combustion test of a sample carpet showed that it exhibited no fire-retarding characteristics. It was observed that if heat accumulated in the carpet, the flame formed an ascending air current, and that when flammable materials were present around the flame, they further accelerated the diffusion of the flame. The carbonization pattern at the carpet surface exposed to direct flame revealed that the carpet surface had melted and had flown downwards and that many tiny holes formed on it.

Long-Distance Plume Detection Simulation for a New MWIR Camera (장거리 화염 탐지용 적외선 카메라 성능 광선추적 수치모사)

  • Yoon, Jeeyeon;Ryu, Dongok;Kim, Sangmin;Seong, Sehyun;Yoon, Woongsup;Kim, Jieun;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.245-253
    • /
    • 2014
  • We report a realistic field-performance simulation for a new MWIR camera. It is designed for early detection of missile plumes over a distance range of a few hundred kilometers. Both imaging and radiometric performance of the camera are studied by using real-scale integrated ray tracing, including targets, atmosphere, and background scene models. The simulation results demonstrate that the camera would satisfy the imaging and radiometric performance requirements for field operation.