• Title/Summary/Keyword: 다수셀 유동

Search Result 5, Processing Time 0.017 seconds

Transition of Natural Convective Flows Subjected to Small-Wave-Number Sinusoidal Wall Temperatures with Phase Difference (위상 차이가 있는 작은 파동수의 정현적인 벽면 온도 하에서의 자연 대류 유동의 천이)

  • Yoo, Joo-Sik
    • 대한공업교육학회지
    • /
    • v.33 no.2
    • /
    • pp.300-311
    • /
    • 2008
  • This study investigates the natural convection of air(Pr=0.7) between two walls having a small- wave- number sinusoidal temperature distributions with a phase difference. The wave number and the phase difference of wall temperatures are k=0.5 and ㄱ/2, respectively. In the conduction-dominated regime at small Rayleigh number, two slightly inclined cells are formed over one wave length. At higher Rayleigh number, however, multicellular convection occurs in thermally unstable region. A spatial symmetry is intermittently broken in the transient period at the Rayleigh number near the critical value. The steady-state flows always satisfy the spatial symmetry. A steep increase of Nusselt number occurs near the Rayleigh number at which transition of flow pattern occurs.

MULTIPLE SOLUTIONS IN NATURAL CONVECTION BETWEEN TWO HORIZONTAL PLATES WITH SMALL MAGNITUDE NON-UNIFORM TEMPERATURE IN THE UPPER PLATE (위 평판이 작은 불균일 온도를 갖는 두 수평 평판 사이의 자연 대류에서의 다중해)

  • Yoo, Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.64-70
    • /
    • 2016
  • Multiple solutions in natural convection of water with Pr=7 between two horizontal plates with small magnitude non-uniform temperature distribution in the upper plate is numerically investigated. The dimensionless temperature of upper plate is ${\theta}={\epsilon}sinkx$. Two upright cells are formed over one wave length in the conduction-dominated regime of small Rayleigh number. However, multicellular convection occurs above a critical Rayleigh number for small wave number. When k = 1.5, dual solutions are found and a transition of $6{\rightarrow}4$ eddy flow occurs with decrease of Rayleigh number. When k = 0.75, two, three, four and five multiple solutions are observed. Transitions of $14{\rightarrow}12$, $12{\rightarrow}10$, $10{\rightarrow}8$ and $6{\rightarrow}8$ eddy flow occur with decrease of Rayleigh number.

The First Part of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (동해화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용(1))

  • Ryu, Ho-Seon;Kim, Bong-Suck
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.259-261
    • /
    • 2007
  • 논문은 동해화력발전처의 이차공기송풍기를 가변 회전수 제어하여 소내 소비 전력을 절감하고 전동기의 직입기동에 의한 스트레스를 줄이기 위하여 실증 적용된 동해화력발전처 이차 공기 송풍기 구동용 H-브릿지 멀티레벨 인버터에 관한 것이다. H-브릿지 멀티레벨 인버터는 독립적으로 절연된 직류 부를 갖는 저압의 단상 인버터(셀 인버터)를 다수 직렬 접속하여 고압 3상 전압을 출력하는 Cascaded H-브릿지 전압형 인버터이다. 본 논문에서는 동해화력발전처에 실증 적용된 6.6kV, 1MVA급 인버터의 계통 병입 후 부하 변동 시험을 통하여 신뢰성을 입증하였다.

  • PDF

Battery Module Bonding Technology for Electric Vehicles (전기자동차 배터리 모듈 접합 기술 리뷰)

  • Junghwan Bang;Shin-Il Kim;Yun-Chan Kim;Dong-Yurl Yu;Dongjin Kim;Tae-Ik Lee;Min-Su Kim;Jiyong Park
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.2
    • /
    • pp.33-42
    • /
    • 2023
  • Throughout all industries, eco-friendliness is being promoted worldwide with focus on suppressing the environmental impact. With recent international environment policies and regulations supported by government, the electric vehicles demand is expected to increase rapidly. Battery system itself perform an essential role in EVs technology that is arranged in cells, modules, and packs, and each of them are connected mechanically and electrically. A multifaceted approach is necessary for battery pack bonding technologies. In this paper, pros and cons of applicable bonding technologies, such as resistance welding, laser and ultrasonic bonding used in constructing electric vehicle battery packs were compared. Each bonding technique has different advantages and limitations. Therefore, several criteria must be considered when determining which bonding technology is suitable for a battery cell. In particular, the shape and production scale of battery cells are seen as important factors in selecting a bonding method. While dealing with the types and components of battery cells, package bonding technologies and general issues, we will review suitable bonding technologies and suggest future directions.

Field Application of H-Bridge Multi-level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan (200MW 석탄화력 순환 유동층 보일러 이차공기송풍기용 H-브릿지 멀티레벨 인버터 현장적용)

  • Kim, Bong-Suck;Ryu, Ho-Seon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.424-431
    • /
    • 2007
  • This thesis proposed H-Bridge Multi-Level Inverter for Fluidized Bed Combustion Boiler Secondary Air Fan in 200MW thermal power plant. The adjustable speed drive systems improve the efficiency in lightly load condition and extend the life span of motor by limiting the over current at starting. H-Bridge Multi-level Inverter is composed of the several series low voltage power cell inverters, which have the independent isolated do link, in each phase. KEPRI(Korea Electric Power Research Institute) has successfully completed to develop, install, and commission H-Bridge Multi-level Inverter(6.6kV, 1MVA). This thesis gives a full detail about H-Bridge Multi-level Inverter, proposed boiler DCS(Distributed Control System) logic, and commissioning test result.