Development of Temperature Control Technology of Root Zone using Multi-line Heating Methods in the Strawberry Hydroponics (다선식 가온방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발)

  • Kim, Ki-Dong;Ha, Yu-Shin;Lee, Ki-Myung;Park, Dae-Heum;Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.189-194
    • /
    • 2010
  • A multi line electric tube consisted of XL pipes contained with 2~4 hot wires and water in it. The specification of one meter length multi-line electric tube was investigated and the proper number in the multi-line electric tube was determined. A multi line electric tube with three hot wires were found to be the most efficient for the media heating control system. Temperature rise of medium in the rice hulls media was faster than that in the perlite media, showed better insulation effect of rice hulls media. Temperature rise of medium with mulching on the top of the bed was faster than without mulching, resulted in the beneficial effect of temperature rise with mulching. The regression model for the rice hulls media with mulching air temperature of $5^{\circ}C$ were a = -0.1458 and b = -0.1088. Using the model, the temperature rise of medium during low temperature season can be predicted for the various media according to the different depths.