Performance Evaluation of Medical Ultrasonic Equipment in Gwangju Using Multipurpose Ultrasonic Phantom (다목적 초음파 팬텀을 이용한 광주 지역 의료용 초음파장비 성능평가)

  • Jong-Gil Kwak;Cheol-Min Jeon;Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.473-481
    • /
    • 2024
  • As a result of measuring and evaluating 24 units of 10 types of medical ultrasonic equipment in Gwangju using the multipurpose ultrasonic phantom (ATS-539), all 24 units were 100% passed in the non-inspection area, vertical distance measurement, horizontal distance measurement, axial/side resolution, gray tone and dynamic range items. As a result of analyzing the ultrasonic phantom pass rate according to the number of years of use of ultrasonic equipment in Gwangju, this study derived that the service life of ultrasonic equipment is related to the equipment performance. As the coverage for ultrasonic inspection is gradually expanded starting with the upper abdominal ultrasound, it is time to further manage the quality of ultrasonic inspection. Therefore, in addition to the standard guidelines for performance measurement for abdominal inspection, research on equipment phantom measurement methods and standards that can be used in various ultrasonic inspection areas such as the neck and chest, which have recently become increasingly important in clinical practice, should be conducted at the same time. In addition, quality control standards should be legally established to maintain the optimal performance of ultrasonic imaging devices and to secure the appropriateness of images. In addition, ultrasound imaging devices should be classified as special medical equipment, and it is considered that the level of equipment should be consistently maintained through continuous management so that images beneficial to treatment can be obtained.

Evaluation of Image Quality using ATS-539 Phantom and SNR in the Ultrasonographic Equipment (ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가)

  • Kim, Min-Ju;Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.284-291
    • /
    • 2013
  • The importance of ultrasound examination in the field of medical imaging has been emphasized and the interest in sonographic image evaluation is growing. However image evaluations by the non-standardized criteria and methods, so establishment of legal provisions and objective evaluation criteria are needed. In this study, we used SNR to find out more quantitative way and supplement the limitations of the existing phantom image evaluation. The results of acquired 8 images using ATS-539 multipurpose phantom were compared in SNR of sensitivity and gray-scale dynamic range. In the result of the experiment, excellent equipment of existing phantom images are G1, S1 and G2 in regular sequence. In SNR of sensitivity, G1, S1 and G2 and in SNR of gray-scale dynamic range, S1 G1 and G2 in order. In the conclusion, all the experiment results did not show big difference and regular pattern neither. Therefore, the new evaluation measures should be used with the existing phantom image evaluation method for more objective and quantitative evaluation of the ultrasound imaging device.

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.

Analyzing Image Quality and Disinfection Effectiveness of Alcohol Gel Application in Ultrasound Scans (초음파 스캔에서 알코올 겔 적용 시 화질과 소독효과 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.365-372
    • /
    • 2024
  • To analyze the image quality and disinfection effectiveness of alcohol gel application in ultrasound scans, we varied the application of alcohol gels with different alcohol content from ultrasound gels. The image quality analysis compared the Dead zone, axial and lateral resolution, sensitivity, and gray scale changes using the ATS-539 phantom, while the disinfection effectiveness analysis was performed by swabbing the three cover faces of convex probe used in clinical practice, collecting specimens and enrichment culture them for 24 hours before identification with Gram stain. image quality analysis showed that all items, regardless of the alcohol content, produced images that were not different from the ultrasonic gel application images, and pathogens such as staphylococcus aureus, streptococcus, and enterococcus were detected on all probes, and all were extinction by the application of alcohol gel. The application of alcohol gel during ultrasound examination was meaningful in terms of image quality maintenance and disinfection effect, and if the results of this study are further studied and commercialized, the application of alcohol gel as an alternative to ultrasound gel will be very useful in clinical examinations because it can consider not only image quality but also infection prevention.

A Study on Effectiveness of Designed Composite Filter with Noise Reduction in Ultrasound Image for Diffuse Liver Disease (미만성 간질환의 초음파 영상에서 노이즈 감소를 위한 복합필터의 설계 및 유용성에 관한 연구)

  • Lee, Jin-Soo;Kim, Changsoo;Im, In-Chul;Yang, Sung-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.69-77
    • /
    • 2017
  • This paper proposes a composite filter for noise reduction of image. To improve the image quality by reducing the noise in the liver ultrasound image, we tried to help the accurate image analysis. In the experiment, the top seven composite filters were selected by combining the Gaussian blur filter, the sharpening filter, and the median filter using the ATS-539 ultrasonic phantom, and applied to the ultrasound image in which this was done. As a result, it was found that the values of SNR, CNR and MSR all increased when the top seven composite filters were applied. In addition, PSNR of more than 30 dB, close to SSIM 1 showed that the image loss rate is small. Therefore, the appropriate application of the proposed composite filter in this research will be useful for accurate video reading and analysis.