• Title/Summary/Keyword: 다공판 시스템

Search Result 39, Processing Time 0.03 seconds

Effect of the perforation shape on the absorption coefficient of multi-layer absorbing system (타공형태에 따른 다중 다공판 시스템의 흡음률 변화)

  • Kang, Jun-Goo;Kang, Hyun-Ju;Kim, Sang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1202-1204
    • /
    • 2006
  • Various types of perforated sheets have been applied on the surface of porous absorptive materials in order to protect dust and to enhance interior design. This study examines experimentally influences on absorptive characteristics according to the shape of perforation which includes rectangular and resonator type as well as circular holes. The measured results shows that the resonance frequency can be changed by the shape of perforation as well as the eccentricity of holes.

  • PDF

A Research on the Noise Reduction of Range Hood for Household (가정용 레인지 후드의 소음저감에 관한 연구)

  • Hong, Byung-Kuk;Song, Hwa-Young;Lee, Dong-Hoon;Lee, Chang-Kun;Kim, Dong-Yun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.449-452
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which squawky noises are generated. Though the squawky noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level omitted front the range hood is decreased above 2dB(A) in all frequency regions due to the effect of noise reduction by perforated panel system.

  • PDF

An Experimental Study on the Sound Absorption of a Membrane Resonance Type System (박막 공명형 시스템의 흡음성능에 관한 실험적 연구)

  • Yang, Soo-Young;Je, Hyun-Su;Hong, Byung-Kuk;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1036-1039
    • /
    • 2004
  • This paper is to experimentally study on the sound absorption of a membrane resonance type system. Membrane resonance type system improves the weak point of a perforated plate system. The experimental results for a membrane resonance type system are explained in comparison with those of a perforated plate system. From the experimental results, it is found that there is an influence of the membrane on the absorption performance. The sound absorbing performances of a membrane resonance system are similar to those of a perforated plate system.

  • PDF

Thermal-Fluid Analysis with Flow Loss Coefficient on the Inlet and Exhaust Duct of Wheel-Loader (휠로더 흡배기구의 유동손실계수를 적용한 열유동해석)

  • Jeong, Chan-Hyeok;Lee, Jae-Seok
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.97-104
    • /
    • 2017
  • In this study, we verify the accurate numerical analysis and simplify the perforated plate of inlet and exhaust duct using porous media for the cost reduction and the efficiency improvement of thermal-fluid analysis to evaluate cooling performance of wheel-loader. The flow loss coefficient of the perforated plate is defined by the experiment result. To define analytically the flow loss coefficient of the perforated plate, we calculate the pressure drop of unit-cell and compare to experiment result. Finally, we compare the heat balance test and the simplified simulation result on the inlet and exhaust duct of wheel-loader. After this study, we verify the applicability of the simplified analysis method on the inlet and exhaust duct of wheel-loader. And, foundation which can carry out effectively the evaluation and improvement for cooling performance of wheel-loader is prepared.

Development of Quality Analysis Method and System for SOFC (SOFC용 셀의 품질관리 기법개발)

  • Lee, InSung;Park, YoungMin;Kim, DoHyeong;Jun, JoongHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.81.1-81.1
    • /
    • 2010
  • SOFC 발전시스템의 상용화를 위해 선행되어야 할 것은 스택의 안정적 출력 및 신뢰성 확보이다. 이를 이루기 위해서는 스택을 구성하는 구성요소의 신뢰성 있는 규격 및 검수가 필요하다. 즉, 셀, 밀봉재, 분리판 및 집전체로 대변되는 구성요소들이 스택에 장착되었을 때 그 기능을 최대한 발휘하면서도 점진적 또는 급격한 품질저하가 발생되지 말아야 한다. 특히, 셀의 경우 스택의 성능에 직접적인 영향을 미치는 구성요소로서 품질에 대한 명확한 검수기준이 필요하다. SOFC용 셀은 다공성 anode, 치밀한 전해질, 그리고 다공성 cathode로 구성된 세라믹 소결체이다. 이 때 치밀한 전해질에 결함이 내재되어 있거나 물리적 힘에 의해 신규로 발생할 경우, 연료로 사용되는 수소와 공기가 만나는 cross-over가 발생하게 된다. Cross-over는 연료가 소모되는 문제도 있지만 발열로 인한 Hot spot을 형성시켜서 주변과의 온도구배를 유발하고, 이로 인해 고체 전해질의 균열전파를 일으킬 수 있고 나아가 급격한 셀의 파괴를 야기할 수 있다. 본 연구에서는 SOFC에 사용되는 셀의 형상측정, 물리적 강도 및 결함 검출을 위한 검수기법을 개발하여 스택의 신뢰성 향상과 향후 규격표준화를 위한 기반을 제공하고자, 평판형 셀의 3차원 형상을 정밀하게 측정하는 장치와 일정 면압을 인가하여 특정 형상을 갖고 있는 셀의 물리적 파괴여부를 판단할 수 있는 장치, 그리고 셀의 전해질에 내재된 결함을 검출할 수 있는 장치를 제작하였다. 본 장치들은 $1,000cm^2$급 평판형 셀까지 검수할 수 있도록 고안하여 양산시스템에 접목시킬 수 있도록 고안된 것이다. 본 장치들을 이용한 검수결과, 현재 $700cm^2$급 평판형 셀의 경우 최대 camber가 4mm 이하, 전해질의 He leak rate는 $5{\times}10^{-5}mbar.l/s.cm^2$ 이하라는 검수규격을 본 연구소에서 운전하는 스택에 1차적으로 적용하였으며 현재 검수규격의 신뢰성 및 강화를 위한 연구를 수행 중에 있다.

  • PDF

An Experimental Study on the Orifice Nozzle System that Generates Micro-bubbles by Self-suction of Air with a Recirculating Flow (재순환 유동 공기 자가흡입에 의한 마이크로버블 발생 오리피스 노즐 시스템에 대한 실험적 연구)

  • Oh, Shin-il;Park, Sang-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.82-88
    • /
    • 2018
  • An experimental study was performed on the orifice nozzle system that generates micro-bubbles by air self-suction using a venturi nozzle. This study experimentally investigates the amount of air sucked into the venturi nozzle and the number of micro-bubbles generated by the orifice nozzle system in Cases 1 and 2. The experimental conditions were varied by changing the diameter of the orifice nozzle (d=2~7 mm) and the number of holes of the perforated plate nozzle (n = 2-12). In Case 1, the air self-suction was more than 2 LPM at $d{\leq}4mm$. When d = 4 mm, the total number of bubbles was 29,777, and it was confirmed that micro-bubbles occupied approximately 65% of the total number of bubbles. In Case 2, the air self-suction was maintained constant at approximately 2.5 LPM regardless of the number (n) of holes. The total amount of bubbles increased when n increased but remained constant at approximately 44,000 when $n{\geq}7EA$. It was also confirmed that more than 80% of all bubbles were micro-bubbles when $n{\geq}10EA$. Thus, the number of micro-bubbles increased by approximately 15% compared to the experimental result of Case 1, which was optimized with d = 4 mm.

Study on the Performance of Total Heat Exchanger with Rotating Porous Plates (다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅰ) - 환기측과 외기측의 풍량 변화에 대하여 -)

  • Cho, D.H.;Lim, T.W.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.11-17
    • /
    • 2005
  • This paper reports an experimental study on the performance evaluation of air-to-air heat exchanger with rotary type newly developed in this study. Air flow rate is varied from 10 to 120 m3/h. The range of RPM of the porous rotating discs mounted inside the heat exchanger unit is 0 to 50. The temperature of the return air side is set by adjusting heat supply at heater. The material of the porous rotating discs is cooper and its thickness is 1.0 mm. The heat transfer rate increased with the increase in air flow rate. It was found that the heat transfer rate, as the temperature of the return air side was increased, was improved due to higher temperature difference. The heat exchange performance increased with the increase in the temperature of the return air side at the conditions of the same RPM. The sensible heat exchange efficiency was maximum 68 to 76 percent, and enthalpy exchange efficiency 64 to 74 percent.

  • PDF

Vibration Test for PCB/Connector Assembly (인쇄회로기판 진동이 커넥터에 미치는 영향)

  • 허남일;김성철;송규섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.160-164
    • /
    • 1995
  • 정보통신 시스템의 고속/고밀도화 요구에 따라 개발되고 있는 ATM(Asynchronous Transfer Mode) 교환기 시스템은 팬을 이용한 강제대류냉각 방식의 채택과 시스템이 설치되는 장소에 따른 여러 환경조건에 의한 진동 문제가 발생될 수 있다. 시스템의 진동으로 인한 피해중 커넥터 접촉부에서 전기적 특성의 변화는 고속으로 전송되는 신호의 왜곡을 유발시킬 수 있어 시스템 개발시 이에 대한 충분한 연구 및 시험이 요구되고 있다. 진동환경에서 커넥터 접촉부는 접촉면의 상대운동으로 인한 접촉저항의 증가와 순간적인 신호전달 중단을 가져오게 되며, 특히 PCB/Connector Assembly에서 커넥터 접촉부는 PCB(Printed Circuit Board)의 장착 조건 및 동적 거동에 따라 전기적 특성이 변할 수 있다. 시스템에서 커넥터의 동적 거동을 이해하기 위해서는 PCB를 포함하는 시스템내 여러 요소의 동적 특성 이해와 복잡한 해석과정이 요구되며, 시스템 개발자는 진동 환경에서 이것의 시험 결과에 따라 커넥터의 사용을 결정해야 할 것이다. 커넥터의 전기적 특성 시험법은 IEC, EIA드 여러 국제 규격에 제시되어 있으며, 본 연구의 대상이 된 ATM교환기 시스템에서 PCB/Connector Assembly의 진동환경에서 접촉저항 측정과 관련된 접촉저항 임계치 및 측정법은 IEEE 규격 및 Bellcore 규격에 규정되어 있다. Bellcore에는 주어진 진동시험주기 전후에 IEC 규격의 LLCR(Low Level Contact Resistance) 측정회로를 이용한 측정법이 규정되어 있고, 냉각팬 및 주위 환경진동이 가해지는 동안의 영향에 대한 시험법은 규정되어 있지 않다. 본 연구에서는 한국통신의 전자장비 운용환경시험 조건의 진동에서 ATM 교환기 시스템에 사용되는 PCB/Connector Assembly 커넥터 접촉부의 접촉저항 변화와 PCB 진동에 의한 영향을 시험하였다.proach)등이 제시되었고 평면파 영역에 한하여 해서되어져 왔다. 본 논문에서는 분할 접근 방법(Segmentation Approach)을 이용하여 다공 요소로 이루어진 소음기를 해석하는데 적용하였다.로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity v

  • PDF

Fabrication of PLA/TiO2 nanofibers using melt-electro-spinning (용융전기방사를 이용한 PLA/TiO2 나노섬유의 개발)

  • Hwang, Ji-Young;Kim, Hui-Jin;Park, No-Hyung;Huh, Hoon;Park, Choon-Keun;Yoon, Jong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.124-128
    • /
    • 2011
  • Electrospun webs have been widely investigated for applying to drug delivery system (DDS) because of their high specific surface area and high porosity. In this study, the composite webs of PLA (poly(lactic acid)) and $TiO_2$ were fabricated by melt-electro-spinning method for applying to drug delivery system. The morphologies of PLA/$TiO_2$, webs were observed using scanning electron microscope (SEM) and field emission transmission electron microscope (FE-TEM). The crystal structures of PLA/$TiO_2$ composite webs were confirmed by X-ray diffractometer (XRD).