• Title/Summary/Keyword: 눈물분포

Search Result 9, Processing Time 0.024 seconds

Comparison of Tear Distributions by the Corneal Eccentricity when Fitted with Spherical and Aspherical RGP Lenses (구면 및 비구면 RGP렌즈 피팅 시 각막 이심률별 눈물분포 비교)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.99-108
    • /
    • 2016
  • Purpose: The present study was aimed to compare the tear volume and distribution by corneal eccentricity when fitted with spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted in best alignment on a total of 77 subjects (136 eyes) in their twenties and thirties without any ocular disease or ocular surgery experience. The tear volume was analyzed by estimating the concentration of tear stained with fluorescein in the center of RGP lens as well as at the mid-peripheral and peripheral areas, and the difference of tear distributions was analyzed according to corneal eccentricity. Results: Tear distribution from the center to the peripheral area was not significantly different when spherical RGP lenses were fitted on the corneal eccentricities of e < 0.38 and $0.68{\leq}e$, indicating the relatively even tear distribution compared with other corneal eccentricity. In the case of aspherical RGP lenses, the difference of tear distribution between the central and peripheral areas was smaller than spherical RGP lenses. The significant difference of tear distribution according to RGP lens design was observed in the corneal eccentricity of 0.48 < e < 0.68. In other words, more even tear distribution was shown when aspherical RGP lenses were fitted on the cornea with eccentricity of $0.48{\leq}e<0.68$ and spherical RGP lenses were fitted on the cornea with eccentricity $0.68{\leq}e$. Furthermore, tear volume in the mid-peripheral area increased with higher corneal eccentricity. Conclusions: The results suggest that the appropriate selection of RGP lens design according to corneal eccentricity is necessary since tear volume and distribution by the regions of spherical and aspherical lenses are affected by corneal eccentricity.

The Effects of Corneal Type and Corneal Astigmatism on Tear Volume between Rigid Gas Permeable Lens and the Cornea (각막형상 및 각막난시도가 RGP렌즈와 각막사이의 눈물양에 미치는 영향)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.141-150
    • /
    • 2015
  • Purpose: In the present study, a difference in tear volume between the cornea and the rigid gas permeable (RGP) lens relative to corneal shape and corneal astigmatism was investigated by the alignment fitting status of spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted with alignment in 77 subjects (135 eyes) who were in their 20~30s. Tear volume stained with fluorescein was qualitatively analyzed by dividing cornea into center, mid-peripheral and peripheral parts. Results: For the spherical RGP lens fitting, tear volume differences were found in each part in all corneal types. For the aspherical RGP lens fitting, tear volume differences were in each corneal part in symmetric bow tie- and asymmetric bow tie-type corneas. However, the tear was equally distributed from the center to the peripheral part in round- and oval-type corneas. In the group with corneal astigmatism lower than 1.25 D, tear volume between center and peripheral parts, and mid-peripheral and peripheral parts, was different when a spherical RGP lens was fitted. However, tear volume in each part was not different in the group with corneal astigmatism over 1.50 D. Moreover, the tear volumes of the central and mid-peripheral parts were proportionally increased with increasing corneal astigmatism in both spherical and aspherical RGP lenses. Furthermore, aspherical RGP lenses showed greater increments than spherical RGP lenses. Conclusions: The results revealed that the difference in tear volume between aspherical RGP lens and cornea was less than spherical RGP lens, and the difference in tear volume varied according to corneal shape and astigmatism. In addition, the method of measuring relative tear volume between RGP lens and cornea that was established in the present study can be used to evaluate tear volume between contact lens and cornea.

A Study on distribution of Dry Eye and Diagnosis Methods (건성안의 분포와 진단 방법에 대한 연구)

  • Ryu, Geun Chang;Park, Hyun Ju;Kim, Jae Min;Lee, Seung A;Ra, Myung Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.91-98
    • /
    • 2000
  • To investigate the distribution of dry eye and to accept diagnosis methods of dry eye in ophthalmic shop, this study was performed on 81 persons(male : 49, female : 32). 1. We divided two group for diagnosing dry eye by dry eye screening questionnaire : one was dry eye symptom group(49.3%) and the other was non-dry eye symptom group(50.7%). 2. Non-invasive break-up time(NIBUT) which was measured by using Tear $scope^{(R)}$ (Killer. co)was longer than invasive break-up time(IBUT). 3. A blink rate in dry eye symptom group(10%) was measured lesser than 10 cycle/min, in non-dry eye symptom group(14.9%). 4. In shirmer test there were lesser than 10mm/5min in dry eye symptom group(67.5%), in non-dry eye symptom group(39%). 5. Cornea and conjunctival staining by rose bengal represented Mild 25%, medium 36.25%, extreme 38.75% in dry eye symptom group. Non-dry eye symptom group was showed Mild 19.51%, medium 14.63%, extreme 12.19%. 6. These results showed that the patient showed dry eye symptom in 3 items of eye examination was 22.5%, 4 items 25%, 5 items 30%, 6 items 15%.

  • PDF

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

Fungal flora of Ullung Island (V) -on additional agaric fungi- (울릉도의 균류상 (V) -기타 주름버섯류에 대하여-)

  • Jung, Hack-Sung
    • The Korean Journal of Mycology
    • /
    • v.22 no.2
    • /
    • pp.196-208
    • /
    • 1994
  • Some additional fungi were collected during two field trips to Ullung Island in July and September of 1992. Through the observation of agaric fungi, 36 mushrooms were identified to the species or subspecies and are listed below. Among them, three species and one subspecies, Mycena luteopallens, Mycena macrocystidiata, Amanita hemibapha ssp. similis, and Pluteus petasatus, were confirmed new to Korea and are registered here with descriptions.

  • PDF

Mathematical Expression of the Toric Cornea using Corneal Topography Measurements (각막지형도(topography) 각막곡률로부터 토릭 각막형상의 수식화)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • Purpose: To represent the shape of toric corea in the elliptical function for the determination of curvature distribution and lacrimal thickness between cornea and contact lens when the lens is fitted. Methods: Topography measurements of corneal curvature and curvature equation derived from the assumed elliptical function were evaluated using the Excel program which included the necessary equation derived. Results: Mathematical expressions for the cornea whose ribbon shaped-topography image, in which the center does not coincide with the corneal apex, can be determined. Conclusions: For the application where the higher accuracy on the cornea is not required, such as higher order aberration, the cornea cal be expressed in the simple elliptical function.

Higher fungi in Mt. Chilgap (칠갑산(七甲山) 지역(地域)의 고등(高等) 균류(菌類)(1))

  • Seok, Soon-Ja;Kim, Yang-Sup;Lee, Kyong-Jun
    • The Korean Journal of Mycology
    • /
    • v.22 no.3
    • /
    • pp.209-215
    • /
    • 1994
  • In order to investigate the fungal Flora in Mt. Chilgap, which located in the middle west of Korea. Authors had collected wild mushrooms, during the mushroom-growing season, June, July and October, 1991. Six species new to the Korean flora are identified as follows: Callistosporium luteoolivaceum (Berk. & Curt.) Sing; Volvariella subtaylori Hongo; Psathyrella subatrata (Batsch) Gill.; Volvariella surrecta (Knapp) Sing.; Boletellus elatus Nagasawa; Xerocomus parvulus Hongo, and Callistosporium Sing. is also new genus to the Korea. All the collections cited are deposited in ASIK herbarium.

  • PDF

Development of Hyaluronic Acid-Functionalized Hydrogel Lens and Characterization of Physical Properties and Lysozyme Adsorption (Hyaluronic acid의 첨가방법에 따른 하이드로겔 콘택트렌즈의 물리적 특성과 lysozyme 흡착량 비교)

  • Lim, Hwa-lim;Kim, Ho-joong;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.285-291
    • /
    • 2015
  • Purpose: The hydrogel lenses have been functionalized with HA(Hyaluronic Acid) using two different methods: construction of an IPN(Interpenetrating Polymer Networks) and formation of CCB(Chemical Covalent Bonding). The lysozyme adsorption and physical properties such as optical transmittance and water content of the hydrogel lenses have been investigated in order to determine whether method is suitable for the application potentials in contact lens industry. Methods: HA have been added to the hydrogel lenses prepared in the Lab using the two different method, e.g. IPN and CCB. The optical transmittance was measured in the wavelength range of 300~800 nm. The water content was measured by the gravimetric method using 0.9% NaCl saline solution. The amounts of adsorbed lysozyme on the contact lenses was analyzed by HPLC after incubation for 12h in artificial tears. Results: The water content of the HA added hydrogel contact lenses was increased, and the lens made by IPN method showed higher water content than the lens made by CCB method. The optical transmittance was over 90% both before and after addition of HA. Comparing the lysozyme adsorption reduction ratio, contact lens manufactured by IPN method was 60.0%, and the lens made by CCB method was 40.4%. Conclusions: CCB method is appropriate to distribute the functional material evenly throughout the lens, whereas IPN method is effective for the case of giving the functionality on the lens surface without phase separation.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.