• 제목/요약/키워드: 누설 진단

검색결과 91건 처리시간 0.026초

산화아연 피뢰기의 열화진단을 위한 저항성누설전류의 고정도 측정기법 및 장치의 개발 (A Development of the High Precise Measuring Device and Methods of Resistive Leakage Current for the Deterioration Diagnosis of ZnO Arrester)

  • 이복희;강성만;전덕규;박건영;최휘성;조성철;백영환;이동환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1668-1670
    • /
    • 2003
  • This paper deals with a development of the high precise measuring device of resistive leakage current for the deterioration and diagnosis of ZnO arresters. The resistive leakage current increasing with time leads to a thermally unstable state that may even experience a disaster. So, the resistive leakage current can be used as an indicator to discriminate whether the ZnO arrester blocks is in good state or in bad. The resistive leakage current measuring system with an analysis program operated with micro-processor using the time delay addition method was designed and fabricated. The proposed measuring systems for the resistive leakage current can effectively be used to develop the techniques of forecasting the deterioration of ZnO arresters in electric power systems.⨀ᔌ?؀㔳㤮㈻Ԁ䭃䑎䷗ᜒं6〰Ԁ䭃䑎䴀

  • PDF

자동차 점화코일의 부분방전특성 (Partial Discharge of Ignition Coil for Automotive)

  • 신종열;김탁용;변두균;김원종;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.239-242
    • /
    • 2003
  • 자동차 점화장치는 전원으로부터 공급된 낮은 전압을 점화코일을 통하여 연소실의 혼합기를 연소시키기에 충분한 고전압을 발생시키는 장치이며, 점화장치의 핵심은 점화코일이다. 이 점화코일은 절연성능이 우수한 절연재료가 사용되지만 고전압의 발생으로 점화코일 내부에서 일어나는 전기적 열화로 인해 누설전류가 흐르게 되어 전기적 고장을 초래할 수 있다. 이로 인하여 절연재료의 수명은 단축되며, 또한 점화코일에 전류가 흐름으로써 코일 내부에서 발생하는 온도변화에 따른 절연열화로 점화코일의 성능이 저하될 수 있다. 따라서 본 연구에서는 점화코일에 사용되고 있는 절연재료에 전압이 인가될 때 발생할 수 있는 비파괴검사의 일종인 부분방전 측정을 통하여 전압변화에 따른 에폭시 성형 점화코일의 위상각($\Phi$) - 방전전하량(q) - 발생빈도수(n)의 특성 변화를 조사하고 분석함으로써 점화코일의 수명을 예측하여 자동차 점화장치의 성능진단과 정보제공을 자동차 전기장치의 발전에 도움이 될 것을 기대하며, 온도상승에 따른 점화코일의 부분방전 특성을 실험하고 분석하였다.

  • PDF

22 kV 케이블의 누설전류 및 절연저항의 선형적 변화 (A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.169-173
    • /
    • 2015
  • 이 논문은 사용한지 13년 지난 운전 중 22 kV 케이블시스템을, 7년 동안 절연저항을 측정하여 그 결과를 연구한 논문이다. 우리는 발전소에서 설치 운전 중인 고전압 케이블이 시간에 따라 성능이 악화되는 현상의 추세를 결정하는 수명지수를 파악하였다. 위한 논문이다. 케이블 시스템은 시간에 따라 절연 저항이 감소한다. 초기 케이블 시스템은 아레니우스 열화 곡선을 따른다. 초기에는 수명 지수 n값이 9로 설계하였고, 이후 n값을 상향하여 16으로 결정하였다. 이유는 고전압에서 케이블이 동작할 경우, n값이 클 때 파괴특성이 높지 않고, n값이 낮은 값에서 파괴특성이 높았기 때문이다. 그러나 전압열화에 의하여 와이블 프롯을 따른 v-t 특성에 의하여 n값은 10~11의 값을 갖는 것을 확인하였다. 과거 케이블 설계 시 정한 n=9의 이론적 근거와 n=16 으로 높아진 원인을 파악함으로써 누설 전류 및 절연 저항의 선형적인 변화를 확인하였다. 단기적으로는 운전 중 케이블 시스템의 진단 평가에 활용되며, 장기적으로는 발전소 부하에서 동작 중인케이블 시스템의 설치 및 운영에 있어서 원가를 절감하기 위한 노력에 기여하고자 한다.

공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구 (Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions)

  • 김양석;김대웅;이병오;정래혁;이승호
    • 대한기계학회논문집A
    • /
    • 제40권6호
    • /
    • pp.613-619
    • /
    • 2016
  • 공기구동 제어밸브는 여러 유형의 발전소에서 유체계통의 유량을 제어하거나 탱크의 수위를 조절하는 중요한 기능을 수행하며 발전소 수명기간 동안 성능이 보장되어야 한다. 공기구동 제어밸브는 공기구동기에 공기를 공급하거나 배기하여 작동시키며, 다양한 기능을 하는 부속기기로 구성된 제어설비를 이용하여 공기량을 조절함으로서 밸브 위치를 제어한다. 본 논문에서는 2인치 공기구동기에 I/P 변환기, 포지셔너 등이 장착된 제어밸브 동작모사 실험 장치를 이용하여 공기공급배관에서의 공기누설, 밸브 패킹마찰력 변화, 포지셔너 설정 불량 등을 모사하고, 약 67% 개도에서 ${\pm}2%$ 이하 제어구간에서의 밸브-구동기 거동을 측정하여 비교하였다.

누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치 (New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents)

  • 길경석;한주섭;송재영;조한구;한문섭
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

등가회로 모델에 의한 레이저다이오드의 누설전류 해석 (Analysis of Leakage Current of a Laser Diode by Equivalent Circuit Model)

  • 최영규;김기래
    • 한국정보통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.330-336
    • /
    • 2007
  • 본 논문에서는 디지털 의료 영상 및 진단 분야 그리고 산업용으로도 활용 가능한 싱글 포톤 계수형 영상센서를 $0.18{\mu}m$ triple-well CMOS(Complementary Metal Oxide Semiconductor) 공정을 사용하여 설계하였다. 설계된 Readout 칩용 싱글 픽셀은 디지털 X-ray 이미지 센서모듈을 간단화 하기 위해 단일 전원전압을 사용하였으며, Preamplifier의 출력 전압인 signal voltage(${\Delta}Vs$)를 크게 하기 위해 Folded Cascode CMOS OP amp를 이용한 Preamplifier를 설계하였으며, 기존의 Readout 칩 외부에서 인가하던 threshold voltage를 Readout 칩 내부에서 생성해 줄 수 있도록 Externally Tunable Threshold Voltage Generator 회로를 새롭게 제안하였다. 그리고, Photo Diode에서 발생하는 Dark Current Noise를 제거하기 위한 Dark Current Compensation 회로를 제안하였으며, 고속 counting이 가능하고, layout 면적이 작은 15bit LFSR(Linear Feedback Shift Resister) Counter를 설계하였다.

가스밸브의 안전관리 현황 및 안전성 향상 연구 (모니터링을 중심으로) (Study on the Current Safety Management Status and Safety Improvement of Gas Valve)

  • 최병규;차민창;김진준
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.57-63
    • /
    • 2016
  • 밸브는 설비 및 시스템의 제어를 위한 필수 요소로써 필수부품이지만 사용 중 Stem에서부터 볼까지의 연결부 유격으로 인한 개폐 불량이 발생할 수 있으며 이물질 유입, 마모, 크랙, 스크래치, 고착, 작동불량 등으로 인하여 사고로까지 이어질 수 있다. 사례 조사 결과 밸브의 고장 원인은 64%가 기밀누설이나 작동불량이었으며, 대부분의 밸브 누출 폭발사고는 설치현장에서 밸브 고착 등 작동불량을 해소하는 과정에서 발생했다. 이는 안전관리와 유지관리에 대한 시스템이 미비하고 안전밸브를 제외한 산업용 밸브의 유지관리 의무화가 되는 법규가 없어 권장사항과 유지관리 업체의 재량에 맡기고 있는 실정이기 때문이다. 따라서 철저한 유지관리로 위험요인을 제거하고 누출 사고 발생 시 피해의 최소화를 위해 초동대처방안이 마련되어야 한다. 본 연구에서는 산업현장에서 밸브의 사용 현황과 유지관리현황을 조사하고 밸브 모니터링을 통한 안전성 향상 방안을 제시하였다. 밸브상태진단 및 운영조회, 가스누출상시감시, 밸브 유지관리 비용절감, 전주기 수명관리 등의 효과를 갖는 모니터링 시스템 구축으로 가스안전관리 고도화에 기여할 수 있을 것이다.

다중채널 와전류탐상검사 장치 개발(II) (Development of a Multichannel Eddy Current Testing Instrument(II))

  • 이희종;남민우;조찬희;유현주;김인철
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.552-559
    • /
    • 2011
  • 전자기유도(electromagnetic induction) 현상을 이용한 비파괴진단기법으로서 최근까지 와전류탐상기법, 교류장측정기법, 자속누설검사기법, 그리고 원격장검사기법 등이 개발되어 활용되고 있다. 이 기법 중 와전류탐상기법은 오늘날 발전설비, 화학, 조선 및 군수설비 등의 열교환기 전열관 비파괴검사에 널리 적용되고 있다. 와전류탐상검사 시스템의 구성은 기능별로 와전류신호 합성 모듈, 아날로그 모듈, 디지털 신호처리를 위한 아날로그-디지털 변환 모듈, 전원공급장치 및 신호취득 평가 프로그램 등으로 구성되며, 선행 연구(I)에서는 다중채널방식의 와전류탐상검사 시스템의 구성 요소 중 1차로 와전류신호 합성 모듈, 아날로그 모듈을 설계 개발하였으며, 2차로 와전류 신호 취득 평가 프로그램을 개발하였다. 2차 연구에서 개발한 와전류 신호취득 평가 프로그램의 운영체제는 "Windows 7"로서 국내 사용자를 위해 최적화 하였으며, 주요 특징은 검사자가 "setup wizard"를 이용하여 검사에 필요한 검사 조건 및 변수를 용이하게 설정하고 이를 이용하여 신호취득 및 평가를 수행할 수 있다. 본 논문에서는 개발된 와전류신호 수집 및 평가 프로그램의 구성과 각 기능을 설명하고자 한다.

진동 데이터 기반 설비고장예지를 위한 신호처리기법 (A Signal Processing Technique for Predictive Fault Detection based on Vibration Data)

  • 송예원;이홍성;박훈석;김영진;정재윤
    • 한국전자거래학회지
    • /
    • 제23권2호
    • /
    • pp.111-121
    • /
    • 2018
  • 항공기 엔진, 풍력발전기, 모터 등 회전기기에서 발생하는 많은 문제들은 진동이나 소음과 같은 신호 데이터를 측정하여 이상감지를 할 수 있으며, 주파수 분석 등 여러 가지 신호처리가 데이터 전처리 단계에서 필요하다. 본 논문에서는 진동 데이터를 분석하여 설비 이상상태를 감지하는 기법을 소개한다. 정상상태 데이터를 기반으로 마할라노비스 거리를 측정하여 이상상태 유무를 모니터링 하는 방식을 사용한다. 특히 신호 데이터의 전처리 기법들을 도입하여 이상상태 감지의 성능을 개선할 수 있음을 보여준다. 전처리 단계에서 신호 데이터 수집 과정에서 발생한 누설오차(leakage)를 없애기 위해 해밍 윈도우(Hamming window)를 적용하고, 신호 데이터의 원신호인 포먼트(formant)를 분리하기 위하여 켑스트럼(cepstrum) 분석을 실시한다. IMS 베어링 진동 공개데이터를 대상으로 시간 구간별로 6가지 통계지표를 추출한 후 마할라노비스 거리 분류기를 적용하여 성능을 검증하였다. 제시된 신호처리 전처리 기법을 적용함으로써 성능이 획기적으로 향상되는 것을 실험에서 보여주었다.

다중채널 와전류탐상검사 장치 개발(I) (Development of a Multichannel Eddy Current Testing Instrument(I))

  • 이희종;남민우;조찬희;윤병식;조현준
    • 비파괴검사학회지
    • /
    • 제30권2호
    • /
    • pp.155-161
    • /
    • 2010
  • 전자기유도(electromagnetic induction) 현상을 이용한 비파괴진단기법으로 최근까지 와전류탐상기법, 교류장측정기법, 자속누설검사기법, 그리고 원격장검사기법 등이 개발되어 활용되고 있었다. 이 기법중 와전류탐상기법은 오늘날 발전설비, 화학, 조선 및 군수설비 등의 열교환기 전열관 비파괴검사에 널리 적용되고 있다. 와전류탐상검사 시스템의 구성은 기능별로 와전류신호 합성 모듈, 아날로그 모듈, 디지털 신호처리를 위한 아날로그-디지털 변환 모듈, 전원공급장치 및 신호취득 평가 프로그램 등으로 구성되며, 본 연구에서는 다중채널방식의 와전류탐상검사 장치(하드웨어) 개발에 필요한 구성 요소중 1차적으로 와전류신호 합성 모듈, 아날로그 모듈을 설계 개발하였다. 본 연구에서 개발한 와전류탐상검사 장치의 특정은 주파수영역 및 시간영역 다중화 방식에 의한 최대 4개 주파수의 동시 적용이 가능한 다중채널장치이다. 와전류신호 합성 모듈, 아날로그 모듈을 구성하는 각 회로에서 와전류신호 발생, 변조, 전처리, 변조 및 신호 디스플레이를 위한 신호가 적절하게 처리되어 최종적으로 와전류신호 평가에 필수적인 리사쥬신호가 임피던스 평면 내에 디스플레이 되는 것을 확인하였다.