• Title/Summary/Keyword: 누설시험

Search Result 267, Processing Time 0.027 seconds

Safety Evaluation of a Shipping Capsule for Special Form Radioisotope (특수형 방사성 동위원소 운반캡슐의 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Ku, Jeong-Hoe;Bang, Kyoung-Sik;Han, Hyon-Soo;Park, Seong-Won
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • All of sealing capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this study is to demonstrate the safety of a shipping capsule for $^{192}Ir$ special form radioisotope which produced in the HANARO. The safety tests were carried out for the impact, percussion, bending and heat test conditions. And leakage tests were carried out before and after the each test. Also, the safety analyses wert performed using computer codes in order to verify the test results. The capsule showed slight scratches and deformation, and maintained its structural and thermal integrities in all tests without any severe damage or melting. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form.

  • PDF

Degradation of Si BJT Leakage Current by High Temperature Reverse Collector-Base Bias Stress (고온 콜렉터-베이스 역전압 바이어스에 의한 BJT 누설전류 특성 열화)

  • Choi, Sung-Soon;Oh, Chul-Min;Lee, Kwan-Hoon;Song, Byeong-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.151-151
    • /
    • 2008
  • 바이폴러 트랜지스터(이하 BJT)의 고온 콜렉터-베이스 역전압 수명시험을 실시하였고, 수영시험 전후의 특성평가를 통해 BJT의 고장모드를 분석하였다. 시험조건은 주위온도 $150^{\circ}C$에서 콜렉터-베이스 정격 역전압의 80%를 인가한 상태에서 실시하였으며, 시료수는 57개이고 최종 목표 시험시간은 2,000시간이다. 중간측정을 통해 BJT의 특성열화를 관찰하였으며, 1,500시간 경과 후 1개 시료에서 제품규격을 벗어나는 데이터가 측정되었다. 해당 시료를 분석한 결과 콜렉터-베이스 누설전류 및 전류이득($\beta$)이 증가하였고, 저주파에서의 junction capacitance 가 정상품 대비 크게 관찰되었다. 측정결과를 통해 누설전류 증가 및 이득이 증가한 원인을 추정하였다.

  • PDF

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.5
    • /
    • pp.57-64
    • /
    • 2010
  • A performance test of inter propellant seal for a 75 ton class turbopump is conducted using water to evaluate leakage and endurance performance. Each part of fuel pump side and oxidizer pump side for a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with one-stage seal of carbon floating ring shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the oxidizer pump side part with two-stage seal assembly of carbon floating rings shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A leakage performance test of the inter propellant seal for cryogenic environment will be performed using LN2 in the near future.

Inter Propellant Seal Performance test for 75 ton Class Turbopump (75톤급 터보펌프 추진제 혼합 방지 실의 성능 시험)

  • Jeon, Seong-Min;Kwak, Hyun-Duck;Park, Min-Joo;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.47-53
    • /
    • 2010
  • A performance test of a 75 ton class turbopump inter propellant seal is conducted using water to evaluate leakage and endurance performance. Each fuel pump side part and oxidizer pump side part of a prototype inter propellant seal has been tested for verifying endurance performance during total accumulated test time 2,100 sec in water. The fuel pump side part with 1 stage carbon floating ring seal shows average leakage rate 13.7 gram/sec under average seal differential pressure 9.4 bar. On the other hand, the LOx pump side part with 2 stage carbon floating ring seal shows average leakage rate 7.3 gram/sec under average seal differential pressure 9.5 bar. After the endurance performance test, the inter propellant seal shows good physical condition. A cryogenic leakage performance test of the inter propellant seal will be performed using LN2 in the near future.

  • PDF

Development of DC Leakage Disconnector for Solar Power Generation System (태양광 발전용 단상 30kW급 직류누전차단기 개발)

  • Han, Hoo Sek;Cho, Sung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1567-1568
    • /
    • 2015
  • 태양광 발전시스템에서 발생되는 누설전류에 인하여 누전화재와 인체감전 등의 전기재해를 방지하기 위해서 직류누전차단기를 개발하였다. 직류누설전류를 측정할 수 있는 센서를 개발하여 (+)전선로와 (-)전선로에 흐르는 누설전류를 각각 검출하는 방법을 제안하였다. 제안된 방법과 개발된 센서를 이용하여 시작품을 제작하고 센서에 대한 감도전류 특성시험을 수행하였다. 또한 인버터가 포함되어 있는 태양광 발전시스템에 적용하여 실제 나타나는 직류누설전류를 측정하는 시험을 수행하였다. 그 결과 직류누설전류센서의 정확성을 확인하였으며, 전선로에 흐르는 직류 및 교류성분의 누설전류를 ${\pm}5%$ 범위 내에서 측정함을 확인하였다. 개발된 센서를 적용한 태양광 발전용 직류누전차단기를 제작하였다.

  • PDF

Corrosion Assessment of Storage Tank Floor using Magnetic Flux Leakage Technique (누설자속법을 이용한 저장탱크 바닥판재의 부식 평가)

  • Won, Soon-Ho;Cho, Kyung-Shik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.38-45
    • /
    • 2000
  • In this research, MFL technique has been studied for the inspection of storage tank floor. The reference specimens having 20%, 40%, 60% and 80% slot's are fabricated using the carbon steel plates of a 6mm and 10mm thick. Powerful permanent magnets and Hall effect sensors are used to this application. It is shown that our system is able to detect metal loss like a slot. Also, it is possible that slot diameter is measured using transverse type of Hall generator. It is demonstrated that MFL can not differentiate between the response from top side and bottom side slot. Flux leakage response from a bottom side indication is significantly lower in amplitude than that from an equivalent top side slot. It is essential to know this sensor lift-off distance because the MFL signal also changes considerably with the sensor lift-off distance.

  • PDF

Development of Propulsion Subsystem for KOMPSAT (다목적 실용위성의 추진시스템 개발)

  • 최진철;양승근;윤효철
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.9-9
    • /
    • 1998
  • 다목적 실용위성의 궤도전이 및 위성체 자세제어를 위한 추진시스템의 설계요소에는 구조적 안전성, 우주환경에서의 열제어를 위한 회로 및 구성하드웨어 설계, 연료계통 맥압강하를 위한 장치설계 및 추력기 배기가스 영향을 고려한 형상설계 등이 있으며, 설계검증을 위해 부분해석이 수행된다. 또한 발사환경과 우주 궤도환경에서의 추진시스템 성능평가를 위한 연제어계 기능시험, 압력인증시험, 청정도시험 및 내부/외부 누설시험이 수행된다. 본 논문에서는 추진시스템 설계 및 조립공정에 대해 기술하였고, 시험분석을 통해 시스템의 설계 및 조립공정상의 신뢰성을 검증 분석하였다.

  • PDF

Leakage Current Characteristics of Experiment Outdoor Stations for Long-term Testing of EHV Insulators (송전용 애자의 옥외 장기실증시험을 통한 누설전류 특성)

  • Choi I. H.;Choi J. H.;Jung Y. H.;Lee D. I.;Jung G. J.;Shin T. W.;Min B. W.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.530-532
    • /
    • 2004
  • 옥외 장기실증시험 설비를 구축하여 154(kV) 송전 전압으로 1년 동안 자기애자(36,000lbs) 및 폴리머 애자(154 [kV] 용)에 대하여 비 또는 눈이 올 때 각 계절에 대한 누설전류 특성에 관하여 조사하였다. 그 결과 자기애자는 누설전류가 장마철, 한여름, 가을의 경우 잦은 집중호우로 첫날은 급격한 증가가 보였으면 폭우 후에는 자연세정으로 인한 폭우 전보다 더 낮게 나타났다. 그리고 겨울에 눈이 올 경우에는 적은 양의 눈으로도 자기 애자 표면에 눈의 쌓여 누설전류가 넓은 시간 높게 나타났으며, 겨울비가 올 경우에는 겨울 동안 눈으로 인해 염분 및 진애의 누적으로 폭우에 대하여 사계절 중 가장 높은 누설전류를 나타났다. 한편 폴리머 애자의 경우에는 사계절에 관계없이 누설전류 증감은 크지 않았으나 겨울비가 을 경우에는 누설전류가 수 백 $[\muA]$까지 증가하였다.

  • PDF