• Title/Summary/Keyword: 농도 측정

Search Result 10,139, Processing Time 0.032 seconds

Aerosol Composition Characteristics at Kosan, Jeju: Measurement Data between 1992 and 2001 (제주도 고산의 입자특성: 1992-2001년 측정결과 요약)

  • 박민하;김용표;강창희
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.85-86
    • /
    • 2002
  • 제주도 고산은 우리나라의 대표적인 배경농도지역으로 동북아시아에서 대기오염물질의 장거리이동 특성을 규명하는데 중요한 지역이다. 이 발표에서는 1992년부터 2001년까지 고산에서 측정한 입자상 무기이온 성분의 농도를 통하여 입자 특성을 파악하고자 하였다. (중략)

  • PDF

Exhaust gas analysis by gas chromatography (가스크로마토그라프를 이용한 배기가스의 농도분석)

  • 윤재건
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.10-19
    • /
    • 1990
  • 본 기고에서는 농도분석에 사용되는 많은 측정장비 중에서 여러가지의 가스성분을 한번에 측정할 수 있고, 다른 전용가스분석기에 비하여 경제적인 가스크로마토그라프를 소개하고, 특히 탄화수소(hydrocarbon)계열의 연료를 사용하는 열기관의 배기가스분석에 국한하여, 적용예와 문제점을 검토하여 가장 최적의 가스크로마토그라프 운용조건을 찾는데 도움이 되고자 한다.

  • PDF

Analysis of Radioactivity in Coal Fly Ash (비산석탄회의 방사능 농도 분석)

  • Shin, Hyun-Sang;Lee, Myung-Ho;Kim, Mi-Kyung;Park, Doo-Wun;Lee, Chang-Woo;Rhee, Dong-Seok
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.187-193
    • /
    • 1999
  • The specific radioactivity concentrations in the coal fly ash obtained from heat producing stations in Korea were analyzed and its radiological hazard for reuse in construction purpose was evaluated. The concentrations of uranium isotopes in the real fly ash measured by TBP solvent extraction method and $\alpha$-spectrometer were found to be about 116.1 Bq $kg^{-1}$ for $^{238}U$, 5.01 Bq $kg^{-1}$ for $^{235}U$, and 121.2 Bq $kg^{-1}$ for $^{234}U$, respectively. The activity ratio of $^{234}U/^{238}U$, in the coal fly ash was in $1.04\;{\pm}\;0.03$, which is similar to that of uncontaminated Korean soil in natural conditions (1.14). The specific radioactivities of $^{226}Ra,\;^{232}Th,\;and\;^{40}K$ in the coal fly ash were also determined using $\gamma$-spectrometer with a HPGe detector The results showed that $^{226}Ra,\;^{232}Th,\;and\;^{40}K$ in the coal fly ash were in concentrations of $101.7{\sim}113.9$, $39.5{\sim}54.2\;and\;315.0{\sim}990.6$ Bq $kg^{-1}$, respectively. With the specific radioactivities obtained from $\gamma$-spectrometric measurements of the coal fly ash, its radiological hazard for reuse was evaluated. The result showed that the radioactivity of the coal fly ash was in permissible level.

  • PDF

The Patterns of the PM Air Quality Guidance Level in Seoul during 1990~2000 (서울시 대기관측망을 중심으로 부유분진 기준농도 초과자료를 이용한 시공간적 경향성 비교 연구)

  • Choi, Ye-Jin;Kim, Min-Young;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.24 no.3
    • /
    • pp.190-204
    • /
    • 2003
  • The PM (particulate matter) concentration data sets exceeding the Daily Air Quality Guidance Levels (i.e., established by the Korean Ministry of Environment) were selected from 31 air qality monitoring stations in Seoul from 1990 to 2000. (For reference, the 24hr environmental standard values of PM$_{10}$ and TSP are 150 and 300${\mu}$g/m$^{3}$, respectively.) When the data sets were compared between land use types, both PM fractions were exceeded most frequently in residential areas. However, the highest TSP concentration was measured at industrial areas (351.0${\pm}$35.9${\mu}$g m$^{3}$), while the highest PM$_{10}$ concentration was measured in residential areas (182.9${\pm}$42.4${\mu}$g m$^{3}$). When the temporal distribution patterns of the exceedance data sets were compared to those measured routinely (without any discrimination based on exceedance criteria), large differences were present. It was demonstrated that the occurrences of exceedance data sets increased rather significantly in recent years.

Development and Application Effect of Gas Concentration Measure Experiment for the Improvement of Elementary School Teachers' Concept on Combustion (초등교사의 연소 개념 향상을 위한 기체 농도 측정 실험 개발 및 적용 효과)

  • Kim, Eun-Young;Kim, Youngshin;Shin, Ae-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.4
    • /
    • pp.296-307
    • /
    • 2015
  • The purposes of this study were to develop the experiment for gas concentration measure during combustion of a candle and to investigate the application effect of the experiment. For this study, 15 elementary school teachers were selected by considering their gender, career, 6th grade science teaching experience, and 6th grade science teaching experience according to 2007 revised s cience curriculum. The experiment using MBL is designed to confirm gas concentrations visually during the combustion of a candle which burns in an acrylic container. The experiment method is as follows. 1) Make two sets of holes in the container and then insert oxygen sensors and carbon dioxide sensors in the holes. 2) Burn a candle in the container and observe the changes in the burning of the candle. The experiment has checked oxygen concentration and carbon dioxide concentration in real-time and displays gas concentration changes by graphs. The results of the application effect of the experiment are as follows. Most elementary school teachers who had not had scientific concepts on combustion got acquainted with scientific concepts about ‘the reason why a candle is blown out when it is covered with a bottle’, and ‘the concentrations of oxygen and carbon dioxide before and after combustion’. In addition, about half of elementary school teachers got acquainted with scientific concepts about ‘the definition of combustion’, and ‘distribution of carbon dioxide during combustion’. Thus, the experiment to measure gas concentrations during combustion is helpful to improve elementary school teachers’ concepts on combustion.

A cohort study on blood zinc protoporphyrin concentration of workers in storage battery factory (축전지 공장 근로자들의 혈중 Zinc Protoporphyrin에 대한 코호트 연구)

  • Jeon, Man-Joong;Lee, Joong-Jeong;SaKong, Joon;Kim, Chang-Yoon;Kim, Jung-Man;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.112-126
    • /
    • 1998
  • To investigate the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, the blood zinc protoporphyrin (ZPP) concentrations of 131 workers (100 exposed subjects and 31 controls) of a newly established battery factory were analyzed. They were measured in every 3 months up to 18 months. Ai. lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean blood ZPP concentration of the controls was $16.45{\pm}4.83{\mu}g/d\ell$ at the preemployment examination and slightly increased to $17.77{\pm}5.59{\mu}g/d\ell$ after 6 months. Mean blood ZPP concentration of the exposed subjects who were employed before the factory was in operation (Group A) was $17.36{\pm}5.20{\mu}g/d\ell$ on employment and it was increased to $23.00{\pm}13.06{\mu}g/d\ell$ after 3 months. The blood ZPP concentration was increased to $27.25{\pm}6.40{\mu}g/d\ell$ on 6 months (p<0.01) after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $25.48{\mu}g/d\ell$ and $26.61{\mu}g/d\ell$ in the subsequent 4 results. Mean blood ZPP concentration of the exposed subjects who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $14.34{\pm}6.10{\mu}g/d\ell$ on employment and it was increased to $28.97{\pm}7.14{\mu}g/d\ell$ (p<0.01) in 3 months later(1 month after the intervention). The values of subsequent 4 tests were maintained between $26.96{\mu}g/d\ell$and $27.96{\mu}g/d\ell$. Mean blood ZPP concentration of the exposed subjects who were employed after intervention program had been started (Group C) was$21.34{\pm}5.25{\mu}g/d\ell$ on employment and it was gradually increased to $23.37{\pm}3.86{\mu}g/d\ell$ (p<0.01) after 3 months, $23.93{\pm}3.64{\mu}g/d\ell$ after 6 months, $25.50{\pm}3.01{\mu}g/d\ell$ after 9 months, and $25.50{\pm}3.10{\mu}g/d\ell$ after 12 months. Workplaces were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3$ and$0.208mg/m^3$ in follow-up test. The Pb-A of part II which was resulted in lowe. value than part I was decreased from $0.232mg/m^3$ to $0.148mg/m^3$, and $0.120mg/m^3$ after the intervention. The Pb-A of part III was tested after the intervention and resulted in $0.124mg/m^3$ in January 1988 and $0.181mg/m^3$ in August 1988. The Pb-A of part IV was also tested after the intervention and resulted in $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-A and blood ZPP concentration. The blood ZPP concentration of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. The blood ZPP concentration of the workers in the part of the lowest Pb-A increased more rapidly. The blood ZPP concentration of the group C workers was the highest in part III. These findings suggest that the intervention in personal hygiene is more effective than environmental intervention, and it should be carried out from the first day of employment and to both the exposed subjects, blue color workers and the controls, white color workers.

  • PDF

Measurement of Al Concentration in Liquid Zinc by E.M.F Method with $CaF_2$ ($CaF_2$ 기전력법에 의한 용융아연 중 알루미늄 농도의 측정)

  • Park Jin Sung;Kim Hang Soo;Jung Woo-Gwang;Katayama I.;Kim Jong Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.204-210
    • /
    • 2000
  • The control of dissolved aluminum concentration in the hot dip zinc galvanizing bath is greatly important in producing galvannealed steel sheets. The purpose of present study is to provide basic data for measurement of the aluminum concentration in site in hot dip zinc bath at the temperature of $460^{\circ}C\~500^{\circ}C$ using $CaF_2$ solid electrolyte sensor with three kinds of reference electrode. Good workability and stability of the sensor were confirmed with the $Bi+BiF_3$ reference electrode from the emf measurement. In order to measure the aluminum concentration in Zn-Al bath, the galvanic cell of fluorine ion was constructed with $CaF_2$ solid electrolyte as follows; $$(-)W|Zn-Al,\;AlF_3|CaF_2|Bi,BiF_3|W(+)$$. The emf measurement was made at the temperature of $460\pm10^{\circ}C$ in the Zn-Al bath. The following correlationship between aluminum concentration and emf was obtained by the least square regression analysis; $$E/mV=56.795log[\%Al]+1881.7\;R=0.9704$$,$$0.026wt\%{\leq}[\%Al]{\leq}0.984wt\%$$

A Study on Selective Metal Ion Sensing Membrane for Bio Environment Measurement (바이오 환경측정용 선택적 금속이온 감지 막의 특성 연구)

  • Park, Hyung-Jun;Jang, Gab-Soo;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1062-1067
    • /
    • 2018
  • In this study, the research processed with a chemical sensor for measuring trace amount of heavy metal ions which is based on the requirements of the efficient sensing technology as recent equipment is applies molecular system in the chemical sensing section that can precisely recognizing selective target substance and transmit its data to physical signal as a result. In this research is concentrated on realize highly precise by utilizing SPR sensor application of recognition functional sensing membrane. Consequently, according to DTSQ-dye sensing membrane, the resonance angle from low-concentration to the highest concentration $10^{-4}M$ of $Ag^+$ ion is $2.17[^{\circ}]$ and this result indicating 4.3 times larger resonance angle changes compare to the other metal substance. Based on SQ-dye sensing membrane, the difference of resonance angle between low concentration and the highest concentration $10^{-4}M$ of $Cu^{2+}$ ion is $2.3[^{\circ}]$ and this outcome is indicating 4.5 times greater resonance angle change to the other metal substance.

Accuracy Comparison between Intensity Method and Count Method in Measurement of Planar Orientation of Fibers Using Image Processing (화상 처리를 이용한 섬유 배향각 분포 측정에서 농도법과 카운트법의 정확도 비교)

  • Lee, S.D.;Kim, H.;Lee, D.G.;Han, G.Y.;Kim, E.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.5
    • /
    • pp.357-364
    • /
    • 1998
  • To investigate accuracies between intensity method and count method for measurement of the fiber orientation distribution, fiber orientation function is derived by drawing simulation figure for the fiber orientation as varying fiber aspect ratio, fiber area ratio, and fiber orientation state, respectively. The values of fiber orientation function measured by intensity method and count method are compared with the calculated ones from simulation figures. The results show that measurement accuracy of fiber orientation angle distribution obtained by count method is by 4% higher than that by intensity method.

  • PDF

Disinfection Effect of Trichloroisocyanuric Acid and Calcium Hypochlorite on Escherichia coli in Water (Trichloroisocyanuric Acid와 Calcium Hypochlorite의 농도 및 접촉시간에 따른 대장균의 사멸특성)

  • 김응수;강자경;박현주
    • KSBB Journal
    • /
    • v.17 no.3
    • /
    • pp.314-316
    • /
    • 2002
  • The disinfection effects of trichloroisocyanuric acid (TICA) and calcium hypochlorite on E. coli in aqueous suspension were comparatively characterized at various concentrations and exposure times of each disinfectant. When the E. coli ($10^{7}$ CFU/mL) cells were exposed with a solution containing 12 ppm each of TICA and calcium hypochlorite, a 90% of the initial cells were killed in 4 sec and 390 sec, respectively. In addition, calcium hypochlorite lost its disinfection effect in about 1 hr exposure under the sun light, whereas TICA maintained its disinfection effect up to 6 hrs under the same condition. These comparative studies demonstrate that TICA is a more effective and stable disinfectant than calcium hypochlorite to sterilize E. coli in aqueous suspension.