• Title/Summary/Keyword: 노즐통과주파수

Search Result 7, Processing Time 0.019 seconds

Vibration Analysis for LP Turbine Blade Damage (저압터빈 블레이드 손상에 대한 진동 해석)

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Yeon-Hwan;Lee, Hyun;Kim, Sung-Hwi
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.752-757
    • /
    • 2003
  • The steady stress, modal analysis for the damaged blade was carried out to evaluate the integrity of LP 4 blade row. As a result, 4 dangerous modes for LP blade row were found in the interference diagram and it was confirmed that the nozzle passing frequency has nothing to do with the blade failure. And then the dynamic stress are analysed for the 4 dangerous modes. There are some points far out of maximum allowable stress in the cover and tenon. Therefore the blade is not safe according to the Goodman judgement. So the manufacturer have modified the design of cover and tenon. Until now, the power plant is being operated without special problems.

  • PDF

Running Bucket Vibration Test of Steam Turbines (증기 터빈 버킷의 회전 진동 시험)

  • 박종포;신언탁;김호종
    • Journal of KSNVE
    • /
    • v.8 no.2
    • /
    • pp.331-335
    • /
    • 1998
  • A design modification was made on the 9-th stage wheel dovetail of a high-intermediate pressure (HIP) turbine rotor for a fossil power plant that necessitates the use of new long-shank buckets for the row. A bucket vibration test is necessary to verify that the new 9-th stage buckets have adequate frequency margin from a nozzle passing frequency when running at speed. A finite element analysis (FEA) has been performed using a commercial S/W to approximately estimate bucket natural frequencies, and thus to help the vibration test. A row of the new buckets has assembled on the HIP rotor for the vibration tests using dynamic balancing facilities. The tests have been done during deceleration run with air excitation. The test results are compared with the calculation using our empirical formula, and show that the modified design meets the frequency-margin requirements.

  • PDF

Natural Vibration and Failure Trouble in LP Stage Blades of Nuclear Power Turbine (원전 터빈 저압단 블레이드의 절손사고와 진동특성)

  • Koo, Jae-Raeyang;Lee, Woo-Kwang;Cho, Cheul-Whan;Kim, Yeon-Whan;Kang, Byeong-Yeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1040-1043
    • /
    • 2006
  • Every mechanical system has a series of natural frequencies at which it will vibrate and to which it will respond if an external stimulus or excitation at this frequency is applied. Vibration is not of itself dangerous, and is always anticipated in an operating unit. However, if the frequency of operation is coincidental with one of the natural frequency of the blade system or the blade has a natural frequency near coincide with the exciting stimulus, then the amplitude of vibration of the blade may increase to the destructive damage can result. In this paper We investigated damage of blade when turbine operated.

  • PDF

Fracture Mechanism of Gas Turbine Compressor Blades in a Combined Cycle Power Plant (복합화력발전소 가스터빈 압축기 블레이드에 대한 손상원인 고찰)

  • Yang, Kyeong-Hyeon;Song, Oh-Seop;Cho, Cheul-Whan;Yun, Wan-No;Jung, Nam-Geun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1025-1032
    • /
    • 2010
  • Gas turbine compressor blades used in a combined cycle power plant are possibly damaged and fractured during their operation. There are two possible causes of the failure of compressor blades; one is a defect of material quality which can be detected through some microscopic inspections for the fracture section, the other is high cycle fatigue problem caused by vibration and can be diagnosed by carrying out dynamic characteristics analysis for the blades. In this paper, in order to determine the cause of the failure of compressor blades in a combined cycle power plant, examination of the fracture section and the propagation mechanism of the crack via stress analysis are performed. Dynamic characteristics analysis via FRF estimation is also performed to identify the cause of failure.

An Experimental Study for Preventing the Resonance of Steam Turbine Blade (증기터빈 블레이드의 공진 방지를 위한 실험 연구)

  • 하현천;이동진;류석주
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.410-415
    • /
    • 2001
  • This paper describes an experimental analysis for improving the stability of blade failure due to the vibration resonance, which happens in the low-pressure steam turbine. Some cracks due to high cycle fatigue were found in the blades of a low-pressure turbine after long time operation. Impact test showed that such failure was mainly caused by the resonance. In other words, since one of the natural frequencies of the grouped blade is very close to the excitation frequency of the nozzle, the resonant vibration leads to a large amplitude of displacement and results in a large amount of stress that may cause fatigue failures in the blades. It is interesting that the blade failures occur only at blades neighboring with the nodal points of the natural vibration mode whose natural frequency is close to the nozzle passing frequency. The effective methods for increasing the reliability against the blade vibration are a heightening the fatigue limit of the blade using an advanced material and a removing the resonance away from the operating speed. It is well known that the removal of theresonance could be obtained by the installation of different types of shrouds, wires, and links between the blades as well as by the chance of the number of nozzles. In the present work, two kinds of modification for avoiding the resonance haute been considered; 1) slot-type finger, 2) long span cover. Full-scale mockup tests have been performed in order to confirm the verification for modification in the shop. Test results show that the use of long span cover is very useful to change the natural frequencies of the grouped blade and to avoid the resonance effectively.

  • PDF

Identification of Failure Cause for 300 MW LP Turbine Blade through Vibration Analysis (진동 해석을 통한 300 MW급 저압터빈 블레이드의 손상 원인 규명)

  • Bae, Yong-Chae;Lee, Hyun;Kim, Hee-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1100-1107
    • /
    • 2005
  • The failure of blades frequently happened in the 300 MW LP(low pressure) turbine until now and they are maintaining the blades periodically during outage. So the blade-disk system is analysed by FEM in order to identify the main cause of failure of blade row. It is found that the stress of root's hole is highest in comparison with other parts from the result of the steady stress analysis. Also, the two dangerous frequencies which is related to the resonance condition are found in the interference diagram. One is 1,316 Hz. The other is 2,981 Hz which is related to the 1 nozzle passing frequency. The dynamic stress analysis is performed to identify more accurate root cause for failure of blade row It is confirmed that the dynamic stress of the former is higher than one of the latter From these results, it is concluded that the former has deeply something to do with the failure of blades more than the tatter. Based on versatile investigation and deliberation, the change of blade's grouping is determined to avoid the resonance condition with the operating speed. After the blade grouping is changed, the former frequency vanish completely but the latter is still in existence in the interference diagram. Fortunately, It is confirmed that the dynamic stress of the new blade grouping is lower than one of the old blade grouping. 2 years has passed since modification and the LP turbine is operated well without failure so far.

이산화탄소를 이용한 방사능 오염 세척 기술개발

  • Ko, Moon-Sung;Park, Kwang-Heon;Ryu, Jung-Dong;Kim, Yang-Eun;Lee, Bum;Park, Hyun-Taek
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.59-59
    • /
    • 2000
  • 원자력발전소 1차계통과 격납용기 내부에서 사용되는 주요 부품들은 운전중에 발생한 방사 성 물질들의 침투와 홉착에 의해 오염되어 간다. 이 오염된 부품 및 장비, 공구, 방호복, 방호모자, 작업화 등의 세정과 정비를 위해서는 제염이 선행되어야 한다. 현재의 제염법은 2차 방사성 폐기물을 발생하는 문제점이 있다. 따라서I 2차 폐기물의 발생을 근원적으로 줄일 수 있는 새로운 제염방안이 절실히 요구되고 있는 실정이다. 본 논문에서는 이러한 문제점을 해결할 수 있는 제염법을 개발하기 위해 2가지 방법을 적용하였다. 첫째로, 원자력 발전소에 서 나오는 방사능 오염 세탁물 제염을 위한 액체 및 초임계 이산화탄소를 이용한 방사능 오염물 제염기를 개발하였다. 제염기는 반응기(16 liteer), 회수시스템 그리고 저장용기로 구성되어있다. 세정에 사용된 모든 이산화탄소는 회수되어 재사용 되어지므로 2차 폐기물의 발생을 근원적으로 없앨 수 있다. 제염성능실험결과 제염지수가 목표치보다는 낮았다. 이는 제염 기에 계면활성제와 기계적인 힘을 가한다면 높은 제염지수를 얻을 수 있을 것으로 예상된다. 둘째로, 발전소에서 나오는 오염된 공구나 장비의 세척을 위한 가변형 노즐 드라이 아이스 세척 장치를 개발하였다. 표면세정시 얼음층 형성방지를 위하여 열공급장치를 부착하였다. 유라표면에 지문을 묻혀 실험한 결과 쉽게 제거되었다. 실제 발전소에 있는 P Pump-housing의 표면을 실험한 결과 방사능의 약 40-80%가 제거되었다. 이 장치는 검출기, 제어장치, 용액상에서 세척될 수 없는 장치에 적용할 수 있는 효율적인 세척법이다. 이는 프리프레그의 표면처리 가 충과 충간의 접착강도를 증가시키고 또한 탄소섬유와 에폭시 간의 계면력을 증가시킨데 기인하는 것으로 사려된다.되었으며, duty-on 시간의 증가에 따라 $Cr_2N$ 상의 형성이 점점 많아져 80% duty-on 시간 경우에는 거의 CrN과 $Cr_2N$ 상이 공존하는 것으로 나타났다. 또한 duty-on 시간이 증가할수록 회절피크의 세기가 증가하여 결정화가 더 많이 진행되어짐을 알 수 있었다. 마찬가지로 바이어스 펄스이 주파수에 다른 결정성의 변화도 펄스의 주파수가 증가할수록 박막이 결정성이 좋아지고 $Cr_2N$ 상이 쉽게 형성되었다. 증착 진공도에 따른 결정성은 상대적으로 질소의 농도가 높은 낮은 진공도에서는 CrN 상이 주로 형성되었으며, 반대로 높은 진공도에서는 $Cr_2N$ 상이 많이 만들어졌다. 즉 $1.3{\times}10^{-2}Torr$의 증착 진공도에서는 CrN 상만이 보이는 반면 $9.0{\tiems}1-^{-2}Torr$ 진공도에서부터 $Cr_2N$ 상이 형성되기 시작하여 $5.0{\tiems}10^{-2}Torr$ 진공도에서는 두개의 상이 혼재되어 있음을 알 수 있었다. 박막의 내마모성을 조사한 결과 CrN 박막의 마찰 계수는 초기에 급격하게 증가한 후 0.5에서 0.6 사이의 값으로 큰 변화를 보이지 않았으며, $Cr_2N$ 박막도 비슷한 거동을 보였다.차 이, 목적의 차이, 그리고

  • PDF