• Title/Summary/Keyword: 노선설계

Search Result 242, Processing Time 0.03 seconds

Exploring Delays of The Mega Construction Project: The Case of Korea High Speed Railway (대형 건설사업의 공기지연분석: 경부고속철도 건설사업을 중심으로)

  • Han, Seung Heon;Yun, Sung Min;Lee, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.839-848
    • /
    • 2006
  • Korea has become the 5th country to own and operate the high speed railroad in 2004. However, there were many difficulties until Koreans enjoy the first bullet train service with the average hourly speed of 300km. The high speed railroad requires elevated quality standards differently from the traditional railways. In addition to the technical difficulties, the construction project itself was an unpleasant case with huge delays and cost overruns mainly due to the lack of experiences, deficiency of owner$^{\circ}{\O}$s role, and increase of public resistances triggered by environmental concerns. This paper analyzes the reasons for delays on this mega-project. With respect to the characteristics of the whole project level, it is very complicated/linear project, whose total length is around 412 km with the composition of various sections in the route of the railway which have basically different conditions. For that reason, the analysis is performed in both macro and micro level. First, macroscopic analysis is performed to find critical subdivisions in the railway route that induces the significant delay in the opening due date. Then, microscopic analysis is followed to quantify the causes and effects of delays focused on these critical subdivisions in more detailed way. Finally, this paper provides lessons learned from this project to avoid the decisive delays in performing the similar large-scaled projects.

Characteristics of Wind Speed and PM10 Concentration underneath Railway Trains (도시철도 차량 하부의 풍속 및 미세먼지 농도 특징)

  • Kim, Jong Bum;Woo, Sang Hee;Jang, Hong-Ryang;Chou, Jin-Won;Hwang, Moon Se;Park, Hyung-Koo;Yoon, Hwa Hyeon;Jung, Joon-Sig;Bae, Gwi-Nam
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.11-19
    • /
    • 2017
  • Since operation of railway trains is a major source of particle pollution in tunnel air, a particle removal device can be an effective measure to remove wear particles. To obtain design conditions of the particle removal device that will be installed underneath the railway trains, the wind speed and particle concentration underneath the trains were investigated using a three-dimensional ultrasonic anemometer and a DustTrak aerosol monitor, respectively. The measurements were made for the trains running on Seoul Metropolitan Subway Line 5 on February 10, 2015. The data were analyzed according to the track geometry (straight, curved) and train speed pattern (acceleration, cruising, and deceleration) between stations. Train speed was also analyzed. The average wind speed and $PM_{10}$ concentration underneath the trains were ~30% of the train speed and ${\sim}200{\mu}g/m^3$ for both straight and curved sections. Average $PM_{10}$ concentration for deceleration sections was higher than that for acceleration sections.

Review of the installable area of multi-utility tunnel using feasibility assessment indexes (타당성 평가지표를 활용한 터널식 공동구 설치가능지역 검토)

  • Oh, Won-Joon.;Jin, Kyu-Nam.;Na, Gwi-Tae.;Cho, Choong-Yeun.;Sim, Young-Jong.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.795-810
    • /
    • 2019
  • In this paper, The study was conducted on the method to roughly determine the area and length of the multi-utility tunnel before the planning and design phase of the multi-utility tunnel construction. For this purpose, four feasibility indexes were used: traffic density, population density, disaster prevention index (number of workers), and urbanization rate, which reflect the regional characteristics. The installation criteria were set in consideration of the average value and minimum value of the feasibility indexes for the tunnel type among areas that can be installed in the multi-utility tunnel of Seoul. The analysis area included 200 areas based on 14 zones. The results of the analysis based on the minimum value of feasibility indexes indicated that the tunnel type of multi-utility tunnel is suitable for 39 areas with high traffic volume and population. On the other hand, the 'gun' area, etc., has a wider population than the 'si' and 'gu', suggesting that it is not suitable to install multi-utility tunnel. In addition, it can be seen that the larger the index value centered on the minimum value of each index, the smaller the tunnel type of multi-utility tunnel installation area.

Rapid Education and Training Methodology for North Korean Construction Workers through a Survey (설문조사를 통한 북한 건설노동자의 급속 양성 교육·훈련 방안)

  • Jung, In-Su;Lee, Giu;Kim, Keum-Ji;Park, Hyeong-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.407-416
    • /
    • 2020
  • North Korea's demand for infrastructure construction and maintenance is growing rapidly. On the other hand, the number of skilled workers is insufficient. Therefore, through a survey of North Korean defectors, this study analyzed the status of construction technology and the difficulties of construction workers. In addition, an attempt was made to derive an appropriate education and training program process and operation plan. As a result of the survey, the reason for the low technical level of construction workers was the lack of skills, lack of motivation to work, and the lack of training and management systems. The appropriate education and training period was 56% of the total response within one year and 36% within six months. Based on the results of this survey, the period of education and training for the rapid training of construction technical personnel in North Korea was adopted as one year. Moreover, compared to the NCS standard in South Korea, appropriate training hours were suggested, excluding training courses, such as planning and design, construction management that require specialized knowledge. Finally, the curriculum corresponding to the education and training courses and the standards for facility names and required areas for facility operation were suggested.

Development of Learning Place for Geologic Field Survey around the Duta Mountain, Chungbuk, Korea (충북 괴산군 두타산 일대의 야외지질조사 학습장 개발)

  • Lee, Chang-Xin;Cheong, Sang-Won
    • Journal of the Korean earth science society
    • /
    • v.26 no.1
    • /
    • pp.41-57
    • /
    • 2005
  • The purpose of the study is to develop a educational data in order for students to perform geologic field survey effectively by themselves. A area around the Duta Mountain is selected. which is located at the southeastern part of Eumsung sedimentary basin because various rock types and geologic structures are well shown in this area and also it is convenient to reach there. Thirteen stops for observation are chosen m a route f3r exercising field geologic investigation. Data for field research are given and described in detail from each stop for observation. To do this, students make their own route map using general or digital geographic map and aerial photo is added to know relationship between large-scale structure and different rock types regionally. Moreover, it is designed to minimize conflict factors that may be experienced from the real field survey by showing outcrop photographs and polarizing photomicrographs of rut samples related to each stop and geologic structures. The attitude of students is investigated with the data of field geologic survey for students of an Earth Science class in the College of Education in Chungbuk National University. The results indicate that the educational data for geologic field survey brought positive changes that greatly help students perform field survey in definitive side, especially formation of absolute concepts on earth science.

Separated Control Signaling Protocol for WDM Optical Networks (파장 분할 다중화 방식을 사용하는 광 전송망을 위한 분리 제어 신호 방식)

  • No, Seon-Sik;Kim, Su-Hyeon;So, Won-Ho;Kim, Yeong-Cheon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.6
    • /
    • pp.1-11
    • /
    • 2000
  • In this paper, we propose a novel control signaling protocol that efficiently controls connection setup and increases the utilization of network resources. The proposed protocol, Separated Control Signaling Protocol(SCSP), separates bearer control from call control lot WDM optical networks. The main function of call control is to check the availability of network resources such as wavelengths and receivers at destination node. Bearer control is to reserve and assign wavelengths. The signaling architecture of this protocol consists of call controller and hearer controller The call controller handles call setup and release, activates the beater controller, and manages the status of call and bearer. The bearer controller reserves wavelengths, sets up bearer, tears down bearer. and notifies the status of beater to call controller. The state transition diagrams of each controller are designed. Using control messages and related primitives, the information flows for call setup and bearer setup, hearer teardown and call release, and reaction for setup failures are described to evaluate the performance. The simulation results show that the separated control signaling protocol is superior to conventional one in terms of call blocking probability and resource utilization.

  • PDF

A Window-Based Permit Distribution Scheme to Support Multi-Class Traffic in ATM Passive Optical Networks (ATM 기반 광 가입자망에서 멀티클래스 트래픽의 효율적인 전송을 위한 윈도우 기반 허락 분배 기법)

  • Lee, Ho-Suk;Eun, Ji-Suk;No, Seon-Sik;Kim, Yeong-Cheon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.1
    • /
    • pp.12-22
    • /
    • 2000
  • This paper presents the window-based permit distribution scheme for efficient medium access control to support multiclass traffic in APON(ATM over passive optical network). The proposed MAC protocol considers the characteristics of QoS(Quality of Service) for various traffic classes. A periodic RAU(request access unit) in upstream direction, includes dedicative request fields for each traffic category within the request slot. The transmission of upstream cell is permitted by the proposed window-based spacing scheme which distributes the requested traffic into several segments in the unit of one spacing window. The delay sensitive traffic source such as CBR or VBR with the stringent requirements on CDV and delay, is allocated prior to any other class. In order to reduce the CDV, so that the permit arrival rate close to the cell arrival rate, Running-Window algorithm is applied to permit distribution processing for these classes. The ABR traffic, which has not-strict CDV or delay criteria, is allocated flexibly to the residual bandwidth in FIFO manner. UBR traffic is allocated with the lowest priority for the remaining capacity. The performance of proposed protocol is evaluated in terms of transfer delay and 1-point CDV according to various offered load. The simulation results show that our protocol has the prominent improvement on CDV and delay performance with compared to the previous protocol.

  • PDF

Structural Strength Evaluation for Development of a Vertical Transfer Device for a Personal Rapid Transit (PRT) Vehicle (PRT 차량용 수직이송장치의 개발을 위한 구조강도 평가)

  • Kang, Seok-Won;Um, Ju-Hwan;Jeong, Rag-Gyo;Song, Joon-Hyun
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.165-173
    • /
    • 2015
  • This paper presents numerical results of static structural stability analysis in development of a vertical transfer device of a PRT(Personal Rapid Transit) vehicle. The vertical transfer of a fully occupied vehicle operating on a road network is the first attempt, which is expected to contribute to overcome the limitations of conventional 2-dimensional operation mode. In particular, the vertical transfer apparatus designed based on vertical circulating conveyors is capable of continuous transfer without time delay so that it enables to accommodate a high traffic density. This system has been frequently used in a logistics field; however, it is essential to assess a structural integrity because an external force by a vehicle weight is exerted on the conveyors in the form of a concentrated load unlike a conventional logistic transport. In this study, prior to the production process, the structural performance of the pilot design in an early stage is numerically evaluated using the commercial finite element method (FEM) solver (i.e., $Ansys^{(R)}$).

A study on efficient management of the drainages of underground tunnels for environmentally friendly urban railway systems (도시철도 친환경 지하터널 배수형식의 효율적인 유지관리 방안 검토)

  • Baek, Jong-Myeong;Hong, Jong-Hun;Kim, Han-Bae
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1982-1990
    • /
    • 2010
  • Excepting tunnel of dorimstream - ccachimountain station section, the subway line No.2th section was build using ASSM and NATM methods because of soil pressure and land condition. The way of dealing underground water was selected without sufficient preconsideration of geographical features, ground condition, influence of lowing underground water, and long-term cost of running maintenance so that the form of undrained tunnel was build having decreased construction characteristics and technically improper elements. The form of partial drainage is very difficult to manage structures of tunnel, because water leakage, water pressure causing cracks of lining concretes and scaling are constantly happened. so partial drainage suggest that setting reinforced Anchor Bolt to prevent buoyancy and should increase center drainage way up to height of railroad. Partial drainage suggest that holey pipe(${\phi}$350mm) manhole, drainage checking pipe manhole are should be regularly dredged, when changing roadbed(gravel${\rightarrow}$concrete) drainage checking pipe manhole should be build and setting a limitation of entering underground water's quantities. Beside drainage degree in changed section of structures causing instability of structures is continuous degree. so if efficient drainage way and the patterns of flaws, problems are considered in survey, it will be expected to have a advantage condition in maintenance part.

  • PDF

A study on correlation between electrical resistivity obtained from electrical resistivity logging and rock mass rating in-situ tunnelling site (전기비저항 검층으로 얻은 전기비저항과 터널 현장 암반등급의 상관관계에 관한 연구)

  • Lee, Kang-Hyun;Seo, Hyung-Joon;Park, Jin-Ho;Ahn, Hee-Yoon;Kim, Ki-Seog;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.5
    • /
    • pp.503-516
    • /
    • 2012
  • Rock mass rating (RMR) is the key factor when designing the appropriate support pattern of tunnel projects. Borehole drilling is usually performed along the tunnel route in order to determine the rock mass rating to be used for tunnel design. The rock mass rating at the non-boring region between boreholes is usually assessed through geophysical surveys such as electrical prospecting, seismic prospecting, etc. Many studies were carried out to find out the correlation between electrical resistivity and rock mass rating. However, most researches were aimed at obtaining the relationship between the two parameters utilizing experimental results obtained from laboratory tests or electrical prospectings. In this paper, efforts were made to analyze and obtain relationships between the electrical resistivity obtained from in-situ electrical resistivity logging data and the rock mass rating. Correlation studies using field data showed that the electrical resistivity is highly correlated with the rock mass rating with the determination coefficient more than 90%. The correlation analysis was also carried out between RMR classification parameters and the electrical resistivity. It was shown that the correlation between the condition of discontinuities and the electrical resistivity was very high with the determination coefficient more than 80%; that between the groundwater condition and the electrical resistivity was very low with the determination coefficient less than 57%.