• 제목/요약/키워드: 노대

Search Result 408, Processing Time 0.028 seconds

Survey on the Green house Flower Soil Chemicophysical Properties and Amount of Fertilizers and Soil Amendment Applications (시설화훼(施設花卉) 재배지(栽培地) 토양(土壤)의 이화학성(理化學性)과 화학비료(化學肥料) 및 토양개량제(土壤改良制) 시용량(施用量) 조사(調査))

  • Hwang, Ki-Sung;Noh, Dae-Chul;Ho, Qyo-Soon
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.2
    • /
    • pp.132-135
    • /
    • 1998
  • This study was conducted to obtain basic information for soil improvement in flower crop cultivating greenhouse soil through survey on the chemical and physical properties of greenhouse soils. Total of 85 Flowcultivating farms were surveyed and analysis was done on the soil characteristics, amounts of chemical fertilizer and soil amendmentuse. The result are as follows: In soil properties of flower cultivating greenhousees, silt clay loam was 51%and 68% of the surveyed soils had good drainage condition. Ground water table was over 90-120cm which was optimum range for flower cultivation. Flower cultivating farms had problem with accumulation of fertility. Nitrate nitrogen was accumulated in Gypsophila paniculate farms and available phosphorus, and exchangeable postassium were significantly higher in greenhouse soils about 2 times than in open field soil. Application amount of chemical feltilizers in greenhouses were nitrate 211,phosphorus 135, and potassium 132kg/ha, respectively. Amount of organic matter used in greenhouse were high in order of cattle manure> compost> organic fertilizer> poultry manure> swine manure and their application amounts were69, 103, 32, 20, and 43 MT/ha, respectively.

  • PDF

Changes in the Chemical Composition and Flavor of Yeast Extracts during the Autolysis of Baker's Yeast (자기소화 시간에 따른 호모 Extract의 성분과 풍미의 변화에 관한 연구)

  • Lee, Cherl-Ho;Park, Chang-Real;Chung, Kyeoung-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.181-187
    • /
    • 1981
  • The changes in the chemical composition of yeast extracts during autolysis and their effect to the sensory quality were studied with baker's yeast, Saccharomyces cerevisiae. The amounts of extracted solids, proteins, amio-N. amino acids, especially glutamic acid, alanine and lysine, increased by the autolysis time up to 48 hrs. The results of sensory evaluation made by the multiple paired comparision test and Duncan's test indicated a significant difference is taste by the time of autolysis. In the profile test, the flavor character notes expressed by the panel were 17 different characters, 11 in aroma and 6 in taste. The character notes and the intensity of flavor changed with the time of autolysis. The sharp and beany flavor of the extracts which was autolyzed for 4 hours turned into meaty and worty flavor by 48 hours of autolysis. A proper arrangement of the flavor characters in the quantitative descriptive chart could provide a weighted value of the flavor grade. The aroma grade index and the taste grade index correlated to the amplitudes of the profile test.

  • PDF

A Study on the Algorithm for Single Phase Control of IGBT PWM Rectifier (IGBT PWM Rectifier의 각상 개별제어 알고리즘에 관한 연구)

  • Kim, Seung-Ho;Park, Jae-Beom;Tae, Dong-Hyun;Kim, Seung-Jong;Song, Joong-Ho;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.26-33
    • /
    • 2016
  • Recently, the use of transformer-less UPS has increased to improve the efficiency of UPS. However, transformer-less UPS is required in three-phase four-wire input IGBT PWM rectifier and the existing three-phase three-wire PFC algorithm cannot be applied in the three-phase four-wire system due to the neutral current problem of UPS input. To control the three-phase four-wire input IGBT PWM rectifier, there are two existing algorithms: 3D SVM and single phase control method. These two algorithms have advantages/disadvantages in controlling the rectifier. The single phase control method is unstable for controlling the rectifier and the 3D SVM method has a problem that must increase the L value of the input-side inductor considerably. Therefore, this paper proposes digital single phase control technology and another new algorithm considering the d-q control, to improve the characteristics of the existing control algorithm. In addition, this paper performed a simulation and experiment based on the proposed control algorithm. The simulation results showed that the proposed technology can control three-phase four-wire IGBT PWM rectifier in a stable manner and can also reduce the neutral current. The proposed algorithm is a useful tool for controlling the three-phase four-wire IGBT PWM rectifier.

A Study on the Countermeasure Algorithm for Power System Disturbance in Large Scale Fuel Cell Generation System (대용량 연료전지발전시스템의 계통외란방지알고리즘에 관한 연구)

  • Kim, Gi-Young;Oh, Yong-Taek;Kim, Byung-Ki;Kang, Min-Kwan;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5550-5558
    • /
    • 2015
  • Recently, fuel cell with high energy efficiency and low CO2 emission is energetically interconnected with power system. Especially, FCGS(Fuel Cell Generation System) which usually operates at high temperature, is being developed and installed in the form of large scale system. However, it is reported that power system disturbances related to surge, harmonic and EMI have caused several problems such as malfunction of protection device and damage of control device in the large scale FCGS. In order to solve these problems, this paper presents a modeling of operation characteristics of FCGS by PSCAD/EMTDC, ETAP, P-SIM software. And also, this paper proposes countermeasure algorithms to prevent power system disturbances. From the simulation results, it is confirmed that the proposed algorithm is useful method for the stable operation of large scale FCGS.

Design and Performance Evaluation of a Scheduling Algorithm for Edge Node supporting Assured Service in High-speed Internet Access Networks (초고속 인터넷 접속망에서 보장형 서비스 제공을 위한 경계 노드의 스케줄링 알고리즘 설계 및 성능 분석)

  • 노대철;이재용;김병철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4C
    • /
    • pp.461-471
    • /
    • 2004
  • Recently, subscribers have strong desire to get QoS based personalized services in high-speed Internet access. Service providers have been rapidly replacing ADSL, cable broadband access networks with Metro-Ethernet based VDSL. But, it is difficult for Motto-Ethernet based broadband access networks to provide QoS based personalized services, because already deployed network elements cannot distinguish subscribers by specific traffic characteristics. In this paper, when the access network has tree topology, we show that it is possible to provide QoS for each downstream flow with only per flow traffic shaping at the edge node without QoS functions in access networks. In order to show that our suggested scheduling algorithm at the edge node can support the assured service in tree topology access networks, we evaluated its performance by simulation. The suggested scheduling algorithm can shape per-flow traffic based on the maximum bandwidth, and guarantees minimum bandwidth per flow by modifying the DRR scheduler. Simulation results show that congestion and loss in the access network elements are greatly reduced, TCP performance is highly enhanced and loss for assured CBR service flows is reduced by only shaping per-flow traffic at the edge node using our proposed scheduling algorithm.

The Study on the Limiting Factor to Determine Available Soil Depth in Korea (우리나라 토양의 유효토심 결정시 저해인자에 관한 연구)

  • Hyun, Byung-Keun;Rim, Sang-Kyu;Jung, Sug-Jae;Sonn, Yeon-Kyu;Song, Kwan-Cheol;Noh, Dae-Cheol;Lee, Heob-Seung;Hyun, Geun-Soo;Zhang, Yong-Seon;Hong, Suk-Young;Park, Chan-Won;Kim, Lee-Hyun;Chol, Eun-Young;Jang, Byeong-Chun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.5
    • /
    • pp.293-302
    • /
    • 2008
  • The limiting factors to determine available soil depth were studied with 390 soil series in soil profile description and physicochemical data in Korean soils. The limiting factors were coarse sandy layer, gravel and skeletal layer, hardpan layer, cat clay layer, poorly drained layer, salt accumulated layer and bed rock layer so on. The soils of having limiting factors were 332 soil series, but soils without limiting factors were 58 soil series. Soils with limiting factors were, hardpan 5, slopeness 93, immature soil 29, cinder 5, sandy 42, gravel or skeletal 47, bedrock 19, high salt content 8, poorly drained soil 22, heavy clay 32, sulfate soil 3 and ash soil 27 etc. And the orders of available soil depth were immature > slopeness > ash > heavy clay > sandy > gravel or skeletal > hardpan > cindery > poorly drained > bedrock > acid sulfate soil > salt accumulated soil etc.

A Case of Primary Pulmonary Sarcoma with Morphologic Features of Malignant Fibrous Histiocytoma (악성 섬유조직구종 형태를 가진 원발성 폐육종 1예)

  • Lee, Youn-Jeong;Hur, Won-Haing;Lo, Dae-Keun;Kim, Seung-Joon;Lee, Sook-Young;Kim, Young-Kyoon;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak;Park, Gyeong-Sin;Lee, Kyo-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.186-191
    • /
    • 2002
  • A malignant fibrous histiocytoma is a malignant soft tissue neoplasm that occurs frequently in the metaphyseal ends of the long bones of adults. The lung is a common site for metastasis but it is a rare site for a primary malignant fibrous histiocytoma. Here we report a case of a primary malignant fibrous histiocytoma of the lung. The patient was a 53-year-old man who presented with a moderate amount of a left pleural effusion and an illdefined mass in the left lower lobe on a chest radiograph and a local invasion to the left 10th and 11th rib on chest CT. Under the strong suspicion of lung cancer with a pleural invasion, a serial diagnostic thoracentesis was performed. The cytologic examination of the pleural effusion revealed no malignant cells. Consequently, a thoracoscopic pleural biopsy was performed. The histological examination revealed slender spindle cells and scattered epitheloid cells arranged in a vague storiform or a whirling pattern. Immunohistochemicaily, the tumor cells tested positive for vimentin and negative for cytokeratin, desmin, CD 34 and PAS. These features were consistent with a malignant fibrous histiocytoma. This case is an unusual addition to the small number of published reports on a primary malignant fibrous histiocytoma of the lung.

A study on the Optimal Configuration Algorithm for Modeling and Improving the Performance of PV module (태양광모듈의 모델링 및 성능향상을 위한 최적구성방안에 관한 연구)

  • Jeong, Jong-Yun;Choi, Sung-Sik;Choi, Hong-Yeol;Ryu, Sang-Won;Lee, In-Cheol;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.723-730
    • /
    • 2016
  • Solar cells in a PV module are connected in series and parallel to produce a higher voltage and current. The PV module has performance characteristics depending on solar radiation and temperature. In addition, the PV system causes power loss by special situations, including the shadows of the surrounding environment, such as nearby buildings and trees. In other words, an increase in power loss and a decrease in life cycle can occur because of the partial shadow and hot-spot effect. Therefore, this paper proposes the optimal configuration algorithm of a bypass diode to improve the output of a PV module and one of a PV array to minimize the loss of the PV array. In addition, this paper presents a model of a PV module and PV array based on the PSIM S/W. The simulation results confirmed that the proposed optimal configuration algorithms are useful tools for improving the performance of PV system.

A Study on the Modeling of Step Voltage Regulator and Energy Storage System in Distribution System Using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 배전계통의 선로전압조정장치와 전지전력저장장치의 모델링에 관한 연구)

  • Kim, Byungki;Kim, Giyoung;Lee, Jukwang;Choi, Sungsik;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1355-1363
    • /
    • 2015
  • In order to maintain customer voltage within allowable limit($220{\pm}13V$), tap operation of SVR(step voltage regulator) installed in primary feeder could be carried out according to the scheduled delay time(30 sec) of SVR. However, the compensation of BESS(battery energy storage system) is being required because the customer voltages during the delay time of SVR have a difficultly to maintain within allowable limit when PV system is interconnected with primary feeder. Therefore, this paper presents modeling of SVR to regulate voltage with the LDC(line drop compensation) method and modeling of BESS to control active and reactive power bi-directionally. And also, this paper proposes the coordination control modeling between BESS and SVR in order to overcome voltage problems in distribution system. From the simulation results based on the modeling with the PSCAD/EMTDC, it is confirmed that proposed modeling is practical tool for voltage regulation analysis in distribution system.

A study on the Operation Algorithm for Bi-directional Sectonalizer in Distribution System Interconnected with Distributed Generations (분산전원이 연계된 배전계통의 양방향 구간개폐기의 동작 알고리즘에 관한 연구)

  • Yoon, Gi-Gab;Jeong, Jum-Soo;An, Tae-Pung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1802-1809
    • /
    • 2009
  • Abstract The typical distribution systems have the power flow from distribution substations (sources) to customers (load) only as one direction. However, in the case where distributed generations (DG) such as PV system and wind power systems are connected to distribution systems, the DG output variations to distribution systems, so called reverse power flow, may cause the bi-directional power flow. So, the reverse power flow has severe impacts on typical power system, for example power quality problems, protection coordination problems, and so on. Especially, protection devices (sectionalizer) in primary feeder of distribution system interconnected with distributed generations may cause problems of malfunction, and then many customers could have problems like an interruption. So, this paper presents the bi-directional operation algorithm of protection devices to overcome the problems like mal-function. And, also this paper shows the effectiveness of proposed method by using both PSCAD/EMTDC software and test facility of protection devices to simulate the field distribution systems.