• 제목/요약/키워드: 냉.난방시스템

검색결과 65건 처리시간 0.028초

병원건물의 에너지 저감을 위한 에너지성능 평가에 관한 사례연구 (Energy Performance Analysis for Energy Saving Potentials of a Hospital Building : A Case Study Methodology Based on Annual Energy Demand Profiles)

  • 조진균;문정환;강호석
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.29-37
    • /
    • 2017
  • Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and design, can be planned for hospital buildings, a category encompassing complex buildings with different setups and large differences between them. Energy-consumption characteristics were surveyed throughout Korea to establish statistical energy models. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy-saving potentials on HVAC systems are presented. The energy performance analysis can be applied to a wide range of problems in energy-system design and planning, including simulations and optimizations of community energy systems.

히트펌프 냉·난방 시스템의 온도 자동제어에 관한 연구 (A Study for Automatic Temperature Control of the Heating-Cooling System with Heat Pump)

  • 구창대
    • 한국산업융합학회 논문집
    • /
    • 제14권4호
    • /
    • pp.143-149
    • /
    • 2011
  • The experiment has been investigated the room temperature change under adjusting 4-way valve which was installed for cooling and heating switch. Beside, the temperature of heat pump was controlled automatically for autonomously adjusting temperature and maintaining a constant room temperature. As results, Inlet & outlet temperature differences of compressor are $95^{\circ}C$ in cooling condition and $57^{\circ}C$ in heating condition. Therefore, Compression efficiency of cooling effect is higher than heating effect. In addition, Heat exchange effect of Cooling system condition is higher than heating system. This results can be used for studying about automatic temperature control of cooling and heating system with heat pump and 4way valve.

${\cdot}$난방 시스템의 부하관리 프로그램 적용 타당성 검토 (feasibility Study in Application on Load Management of Cooling or Heating Systems)

  • 손학식;김회철;김형중;허동렬;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.686-688
    • /
    • 2004
  • We suggest that the core factor which can be established successfully pushing ahead with domestic load management program is finding and keeping management of controllable load resources. We know that load management is mostly the maximum demand power management and participation of DLC program. This paper suggests the way coping with load management suggesting model which air conditioning and heating load facilities are applied to DU program.

  • PDF

건축물 냉.난방 시스템에 따른 에너지 소비 특성 -서울 소재 A 대학교 건축물을 중심으로- (The Energy Consumption Characteristics of Building Accordance with Air-Conditioning and Heating System)

  • 박강현;차정훈;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.333-337
    • /
    • 2011
  • Central control air-conditioning systems are being replaced with individually controlled air-conditioning system in the university. The amount of growth of electricity consumption is due to the increasing demand of electric heat pump. In winter and summer, the energy consumption showed a tendency to increase. On the other hand, showed less energy in spring and autumn. Increase the amount of electricity than the degree of decline in gas consumption was higher. Can be considered as transitional phenomena. Because electric heat pump, gas driven heat pump and the absorption chiller-heater are used at the same time in some of the buildings.

  • PDF

공동구내 분무분포에 관한 연구 (A Study on the Water Spray Distribution in Underground Culvert)

  • 김엽래
    • 한국방재학회 논문집
    • /
    • 제4권3호
    • /
    • pp.83-87
    • /
    • 2004
  • 지하공동구내에는 전력, 통신, 가스 냉 난방배관 등 생활에 필요한 공작물이 수용되어 있다. 미래에 지하 공동구의 사용은 확대되며, 화재의 위험이 증가될 것이므로 미연에 화재에 대비해야 하며, 지하공동구내 최대한의 연소방지효과를 가져오게 할 수 있는 소화시스템의 연구가 필요하다. 본 논문은 지하공동구내 화재를 진압하기 위한 노즐의 분무분포를 해석하고, 이에 따라 지하공동구의 화재안전성능을 확보하고자 한다. 앞으로 화재 및 재해예방을 위해 국내기술로서 국내 환경에 맞은 소화시스템 연구가 지속적으로 이루어져야 할 것이다.

지열을 이용한 학교시설의 냉·난방시스템 효율성분석 -에너지 소비량을 중심으로- (Efficiency Analysis of the HVAC system in the School Facilities Using the Geothermal Energy -Focused on the energy consumption-)

  • 박동순;이재림
    • 교육녹색환경연구
    • /
    • 제6권2호
    • /
    • pp.25-52
    • /
    • 2007
  • This paper is focused on the economical efficiency of the geothermal heat pump system in school. As the importance of problems of environment and energy becomes larger, the development and distribution of energy-saving technology in the whole nation has become influential. This paper is intended, targeting on school buildings scattered all over the country, to evaluate the introduction and possibility of a terrestrial heat system which is in the first stage of introduction in the country, through energy consumption and efficiency in case where a terrestrial heat system is introduced. To do that, the author performed a qualitative analysis of the heat pump system using various terrestrial heat energy and the system introduced to existing school buildings and, through the analysis, made tentative evaluation on the most environment-friendly and energy saving type system. Also, the author performed simulation analysis using a currently typical school building standard and, on the basis of this result, conducted efficiency analysis of various heat pump systems. The conclusion according to synthetical analysis & evaluation can be summarized as follows. In case a heat pump system is introduced to a school building, it was deemed the investment in the early stage would increase, but the investment could be collected within 5~6 years through reduction of large operation expenses. Also, it was analyzed in case of terrestrial heat contracted heat mode using midnight electric power among heat pump systems, not only early investment but also operation expenses could be reduced to a great extent. Accordingly in case the system using terrestrial heat energy is applied to the school buildings that are to be newly built or repaired in the future, it will provide an object-lesson to students as well as contributing to energy saving.

  • PDF

콘트롤 밸브의 소음 측정 방법 (Measurement method for control valve noise)

  • 이용봉;윤병로;박경암;이두희;유선학
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2002년도 하계학술발표대회 논문집 제21권 1호
    • /
    • pp.515-518
    • /
    • 2002
  • 콘트롤밸브는 지역 냉${\cdot}$난방 및 APT, 대형 빌딩의 냉온수, 중온수 및 공조배관 시스템에 사용되어 유체적 바란스를 이루는데 사용된다. 이와같이 유체의 흐름을 조절하기 위하여 사용되는 콘트롤 밸브가 때로는 소음 문제를 일으키기도 한다. 최근 들어 밸브의 소음이 문제가 되는 경우가 빈번해 지고 있다. 밸브의 기본적 기능을 충족시키기 위해서는 영구적인 수두 손실이 필요하며 이러한 수두손실을 발생시키는 과정에서 유체 흐름에 의해 발생한 난류가 커다란 밸브 소음을 유발하게 된다. 본 연구에서는 콘트롤 밸브 소음 특성 평가 방법을 검토하였다. 밸브 및 배관으로 이루어진 시스템에서 발생되는 소음을 예측하는 절차를 살펴보았다. 밸브의 음향 파워레벨을 측정하고 유량 및 차압의 변화에 따른 소음 예측식을 결정 하였다. 본 연구에서 제시한 밸브 소음 측정 방법은 새로운 밸브의 소음특성 평가, 밸브 소음의 예측 그리고 서로 다른 밸브 사이의 성능비교 등에 사용될 수 있을 것이다.

  • PDF

병실 냉.난방장치용 태양 위치 추적기를 이용한 태양광 발전시스템에 관한 연구 (A study on Photovoltaic System to Considers a Solar Position Tracker for Air Conditioner a Clinic room)

  • 황락훈;나승권
    • 한국산학기술학회논문지
    • /
    • 제8권6호
    • /
    • pp.1355-1362
    • /
    • 2007
  • 본 논문에서는 태양광 발전의 효율을 높이기 위하여 센서와 마이크로프로세서를 이용한 태양광 위치추적 장치를 설계하여 고정 방식의 태양광 발전과 위치 추적 방식의 태양광 발전에 대하여 비교해 보았으며, 태양전지에 대한 특성 해석과 수학적 모델링을 통한 시뮬레이션을 행하여 태양전지 특성 사양과 비교해 보았다. 또한 전력변환 시스템을 Boost 컨버터와 전압형 인버터로 구성하여 각각에 대하여 실험하였으며, Boost 컨버터 제어에서 최대 전력점 추적을 위해 일정전압 제어법을 사용하였다. 인버터의 제어에서는 SPWM(Sinusoidal Pulse Width Modulation) 제어법을 사용하여 실험하여 좋은 결과를 나타내었다.

  • PDF

태양열 이용 Hybrid냉난방시스템 실증연구 (Demonstration project on utilization of solar thermal energy on Hybrid Cooling and Heating system)

  • 문종철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.363-372
    • /
    • 2005
  • 최근 고유가상황 및 에너지소비가 증대되는 사회적 분위기와 환경적 변화에 힘입어 대체에너지기술개발에 대한 절실한 대책마련이 중요시 되고있다. 기후변화협약의 발효로 환경에너지에 대한 새로운 인식의 필요로 에너지체제의 변환이 촉구되어지고 있으며 이에 따른 환경친화적 에너지자원을 이용한 신 재생에너지개발에 대한 연구개발기술이 관심을 받고 있다. 현재 사용중인 화석연료는 환경오염 및 지구의 온난화 현상 등 심각한 공해문제를 야기시키고 있는 반면에 태양에너지와 같은 청정에너지의 개발은 환경오염방지와 친환경에너지자원의 활용이라는 점에서 관심이 대상이 되고 있고 특히, 우리나라의 경우 에너지수입 의존율이 97%로 높은 상황에서 국가에너지대책을 수립하고 해외수입에너지 의존율을 최소화시키기 위하여 가히 필수적인 상황이다. 따라서, 본 실증연구사업(태양열 이용 Hybrid냉난방시스템 실증연구)은 태양열 집열기에서 생산된 저온의 $20\sim30^{\circ}C$의 승온된 양질의 열원을 히트펌프 증발기 열원으로 이용 히트펌프의 압축동력이 상대적으로 작아져 기존 히트펌프 시스템에서의 성적계수(COP)를 높여 주는 효과를 기대할 수 있고, 특히 하절기 복사량이 많은 시기에는 $50\sim60^{\circ}C$ 정도로 승온되어진 중 고온수를 직접 온수탱크로 이동시켜 필요수요처에 공급함으로써 이에 따른 에너지절감효과를 기대할 수 있다. 구축된 태양열 이용 하이브리드(Hybrid)냉난방시스템은 계절별, 설비별 특성을 적절히 활용하여 연평균 집열기 효율은 70%수준으로 유지하면서, 계절별 성적계수는 '4'수준을 목표로 하여 추진되었으며, 그간, 태양열 이용 보급분야의 실용화는 주로 건물의 급탕용 온수생산의 수준에 머물렀으나 이 단계를 극복한 건물의 냉 난방 및 급탕을 위한 태양열 및 공기열원을 활용한 하이브리드(Hybrid)냉난방 시스템 구축하였다. 아울러, 태양열 이용 하이브리드 냉난방 히트펌프 시스템 실증 실험은 유가상승과 신재생에너지에 대한 국가적 분위기 고취로 어느때 보다도 개발기술의 상용화 및 실용화적 측면의 염두와 태양열 이용 Hybrid냉난방 시스템의 효율향상과 저가화를 통해 기술의 경제성과 신뢰성을 확보하여 태양열 이용 시스템의 보급활성화를 목표로 하고 있다.

  • PDF

지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가 (Cooling and Heating Performance Evaluation of a GSHP System)

  • 손병후;조정식;신현준;안형준
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.