A Experimental Study on the Characteristics of Waste Heat Recovery Type Triple Heat Exchanger in the Cooling and Heating Systems (냉난방 시스템계 폐열 회수용 3중관 열교환기 특성에 관한 실험적 연구)

  • Lee, Kwang-Bae;Lee, Ho-Saeng;Moon, Chun-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1091-1095
    • /
    • 2005
  • This study is performed to develop a tripple-tube exchanger which can improve the system efficiency. Three different tube diameters are compacted by one body(tripple-tube) to recover waste heat from heat exchanging among the fluids. With this, the tripple-tube shows higher cooling capacity than the double-tube after comparing between those two systems. The results of this study are basic data to design the optimum tripple-tube heat exchanger.

  • PDF

Studies on Management of Effective Temperature and Humidity in Greenhouse at Summer Season (하절기 효율적인 하우스 온도 습도 관리에 관한 연구)

  • 우영회;남윤일;송천호;김형준;김동억
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.58-65
    • /
    • 1994
  • It is necessary to effective temperature and humidity management for normal growth of crops in protected cultivation during the summer season. Because the highest temperature of vinyl house inhibit normal growth of crop and decrease of crop production or marketability in summer season. Finally, the vinyl house was impossible some crop cultivation in summer season. This study was conducted to investigate effective and economic method for temperature drop in protected cultivation during the summer season. 1. In medium size vinyl house(5$\times$13$\times$3m), the effect of temperature drop appeared the highest in treatment of shading with aluminium thermal curtain+fog system+ventilation with fan. The effect of temperature drop was about 1$0^{\circ}C$ lower than outer air temperature and about 4$^{\circ}C$ lower than outer soil temperature. 2. The effect of temperature drop according to shading with aluminium thermal curtain+fog system+ventilation with fan during the highest temperature of summer season Jul., 20 to Aug., 21 was appeared about 8$^{\circ}C$ lower than outdoor above ground(1.2m) and about 7$^{\circ}C$ lower than outdoor surface ground. 3. The changes of solar radiation during a day according to shading with aluminium thermal curtain+ventilation with fan and shading with black curtain+ventilation with fan treatments was appeared respectively about 29.3%, 32.5% of outdoor solar radiation a fine day and respectively about 27.4%, 31.8% of outdoor solar radiation a cloudy day.

  • PDF

Experimental Investigation on the Performance of Small-Sized Dehumidification Rotor for Residential Use (가정용 소형 제습로터의 성능에 대한 실험적 연구)

  • Han, Ji-Chao;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2344-2349
    • /
    • 2015
  • In Korea, summer is hot and humid, and air-conditioners consume too much electricity due to large amount of latent heat. Simultaneous usage of dehumidifier may reduce the latent heat and save the electricity. In this study, dehumidification performance was measured in a constant temperature and humidity chamber for a small-sized dehumdification rotor made of inorganic fiber impregnated with metallic silicate. Variables were rotor speed, room temperature, regeneration temperature, room relative humidity and frontal velocity to the rotor. Results showed that there existed optimum rotor speed (1.0 rpm), and optimum regeneration temperature ($100^{\circ}C$). Above the optimum rotor speed, incomplete regeneration is responsible for reduced dehumidification. Above the optimum regeneration temperature, increased temperature difference between regeneration and dehumidification process is responsible for reduced dehumidification. The amount of dehumidification also increases with the increase of relative humidity, dehumidification temperature and flow velocity into the rotor.

Computer Simulation Study for Analyzing Alternative Refrigerants in Residential Air-conditioners (가정용 냉방기의 대체 냉매 성능 분석을 위한 전산 해석 연구)

  • Yoo, Hwaan-Kyu;Jung, Dong-Soo
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.75-90
    • /
    • 1995
  • This paper is concerned about alternative refrigerants for HCFC22 used in room air conditioners and heat pumps. Computer simulation of residential air conditioners using refrigerant mixtures is carried out. Following refrigerants are selected as the pure refrigerants constituting the mixtures studied: R32, R124, R125, R134, R134a, R143a and R152a. Simulation results are presented fur the following mixtures: R32/R134a, R32/R152a, R32/R134, R32/R124, R143a/R134a, R143a/R152a, R143a/R124, R125/R134a, R125/R152a, R125/R124, R32/R152a/R134a, R32/R152a/R134, R32/R152a/R124. The best fluid is found to be the ternary mixture of R32/R152a/R124. For that mixture, the coefficient of performance(COP) and volumetric capacity for refrigeration(VCR) are 13.7% larger and 23% smaller than the respective values for HCFC22. R32/R124 mixture is the best binary fluid pair whose COP and VCR are 13.4% larger and 9.6% smaller than those for HCFC22.

  • PDF

Effects of Urban Greenspace on Microclimate Amelioration, $CO_2$ Sequestration and Eire Obstruction (도시녹지의 미기후개선, $CO_2$흡수 및 화재방지의 효과)

  • ;Yoshiteru Nojima
    • Korean Journal of Plant Resources
    • /
    • v.13 no.3
    • /
    • pp.162-170
    • /
    • 2000
  • This study quantified the effects of urban greenspace on microclimate amelioration and atmospheric $CO_2$ reduction for several residential districts selected in Korea and Japan. The study also explored fire obstruction by urban trees to develop systematic planting guidelines. Transpiration by a Zelkova serrata tree (diameter at breast height: 15 cm) in a day of August equaled cooling effect of about 3 air conditioners running for 12 hours. Average air temperature for the growing season was 0.5$^{\circ}C$ and 1.2$^{\circ}C$ cooler, respectively, in districts with 12% and 22% cover of woody plants than in a district with no vegetation. Annual $CO_2$ uptake and $O_2$ production by woody plants were 3 times greater in a district which was 2 times higher in their cover. Woody plants played, in a district with their 22% cover, an important role through offsetting total $CO_2$ emission from the district by about 3% annually, and through producing 10% of annual $O_2$ requirement by all residents within the district. Appropriate planning strategies of residential greenspace, including species selection, planting layout, greenspace enlargement, and maintenance were suggested to improve microclimate amelioration, air purification, and fire obstruction.

  • PDF

An Experimental Study on Performance of Energy Recovery Ventilation System (폐열회수 환기시스템의 성능에 관한 실험적 연구)

  • Kim, Young-Soo;Choi, Kwan-Soo;Kim, Il-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.445-450
    • /
    • 2012
  • At the limited space, the air conditioning may have difficult to control temperature or humidity for home use. Nowdays, the people reponse to temperature or humidity sensitively. This becomes the Indoor Air Quality (IAQ) is an important factor for comfortably. Heat recovery ventilator (HRV) is used for the solution of inconsistency between IAQ and power-saving. Also, the thermoelectric element is applied to HRV and compared with temperature efficiency and verifying the capacity of the system. To improve the temperature efficiency a single motor and thermoelectric element with the conductive guide vane is experimented. The results shows that it can save 23 W by using the single motor. The developed system of 250 CMH capacities with the thermoelectric element reveals the temperature efficiency improvement of 4.01% in cooling period and 2.98% in heating period compared to the conventional system.

Experimental Study on Influence of Flow Rate Ratio in a Dehumidifier with a Solar Desiccant Apparatus (태양열제습장치 중 제습기에서의 유량비 영향에 관한 실험적 연구)

  • Choi, Kwang-Hwan;Rokhman, Fatkhur
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.8-15
    • /
    • 2011
  • 제습기의 역할은 태양열제습냉방시스템 요소 중에서도 매우 중요하다. 본 논문은 이러한 특성에 맞추어 제작된 장치를 갖고서 제습능력에 영향을 미치는 유량비를 바꾸어 실험한 결과이다. 실험은 크기가 $40m^3$인 항온항습실을 대상으로 이루어졌으며, 향류형 제습기의 수직 높이는 0.4m로 고정되었다. 또한 충진층은 액체흡수제와의 접촉면을 넓게하기 위하여 플라스틱 충진재로 채워져 있으며, 흡수제의 온도는 빠른 변화를 보기 위하여 $15^{\circ}C$로, 농도는 40%로 고정하였다. 액체흡수제의 유량과 습도가 높은 공기의 유량을 각각 3단계로 바꾸어 실험한 결과, 풍량이 높을수록 제습기 효과는 낮아졌으나, 전체적인 제습량에서는 많아졌다. 한편, 제습기에서 액체흡수제 유량이 많을수록 제습되는 수분량이 많아졌으나, 시간의 변화에 따라 제습되는 속도는 현저하게 낮아졌다. 따라서, 향후 실험에서는 유량의 변화 폭을 더욱 확대해서 많은 실험 결과를 확보하고, 이를 모델링화 하여 높은 정확도를 예측할 필요가 있다.

군집분석을 이용한 새로운 IS 실무자 분류 체계에 관한 연구

  • Gyeong, Won-Hyeon;Go, Seok-Ha
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2006.06a
    • /
    • pp.573-601
    • /
    • 2006
  • IS 실무자들은 과거처럼 단순한 시스템 분석이나 프로그래밍 기법만을 갖추는 것만으로는 조직이 원하는 정보기술을 효과적으로 운용하는 것이 어렵게 되고 있다. 예전과는 달리 최근의 기업에서는 통신 시스템을 포함하는 다양한 정보기술에 관련된 지식과 기술을 전문적으로 다룰 수 있는 전문가를 원하는 추세이다. 이러한 맥락에서 IS 실무자들이 자신의 업무를 성공적으로 수행하기 위해 필요한 전문 지식과 기술은 무엇인가라는 질문에 대한 대답을 알 수 있어야만 한다. 본 연구는 IS 실무자들이 그들이 직면하고 있는 ‘IS 지식과 기술의 빠른 변화’를 얼마만큼 인식하고 있으며, 그들이 필요로 하는 지식과 기술과 업무를 수행함에 있어 필수적인 지식과 기술을 얼마만 큼 보유하고 있는지를 조사하였다. 본 연구에서는 조사된 자료를 통하여, 기존의 국내외의 문화에서 밝혀진 인구 통계학적 분류기준 (예를 들자면, 경력 수준, 지역, 직종) 이외에 이들을 분류할 수 있는 기준에는 어떠한 것이 있는가에 대한 연구를 수행하였다. 분석을 위하여 실무자들이 현업에서 많은 시간과 노력을 들이고 있는 IS 활동영역에 대한 투자시간을 기준으로 실무자들을 분류하였다. 분석에서는 조사자의 군집분석과 다차원 분석을 통하여 분류된 실무자 그룹에 대한 여러 가지 기술적인 특성과, 인구 통계학적 특성을 파악하고, 그룹들에 대하여 새로운 분류에 적합한 표기를 제시하고자 하였다. 본 논문은 정보시스템 영역에서 수행된 IS 실무자들에 다양한 연구의 한 부분으로서, 기업 환경, 조직 환경, 나아가 실무자들의 직무환경의 개선에 필요한 지식과 기술을 제공할 것이다.아날로그 방식에서 IT 기반에 의한 디지털 환경으로 변화되고 있다. 또한 e러닝, T러닝, m러닝, u러닝 등의 용어가 생성되고 있다.키지에어컨에서 사용되고 있는 밀폐형 압축기에 대해서 그림 2에서 나타내고 있는 냉방능력 10tons(120,000Btu/h) 이하를 중심으로 상기의 최근 기술 동향을 간략하게 소개하고자 한다.질표준의 지표성분으로 간주되는 진세노사이드의 절대함량과 그 성분조성 차이에 따른 임상효과의 차별성이 있는지에 대한 검토와, 특히 최근 실험적으로 밝혀지고 있는 사포닌 성분의 장내 세균에 의한 생물전환체의 인체 실험을 통한 효과 검정이 필요하다. 나아가서는 적정 복용량의 설정과 이와 관련되는 생체내 동태 및 생체이용율(bioavilability)에 관한 정보가 거의 없으므로 이것도 금후 검토해야 할 과제로 사료된다. 인삼은 전통약물로서 오랜 역사성과 그동안의 연구결과에 의한 과학성을 가지고 있으므로 건강유지와 병의 예방 및 회복촉진을 위한 보조요법제 또는 기능성 식품으로써의 유용성이 있는 것으로 판단된다. 앞으로 인삼의 활용성 증대를 위해서는 보다 과학적인 임상평가에 의한 안전성 및 유효성 입증과 제품의 엄격한 품질관리의 필요성이 더욱 강조되어야 할 것이다.xyl radical 생성 억제 효과를 보여 주었다. 본 실험을 통하여 BHT 를 제외하고 전반적으로 세포 수준에서의 oxidative stress 에 대한 억제 효과를 확인해 볼 수 있었으며 특히 수용성 항산화제들에서 두드러진 효과를 보여 주었다. 제공하여 내수기반 확충에도 노력해야 할 것 이다.있었다., 인삼이 성장될 때 부분적인 영양상태의

  • PDF

Study on the Compared between u-Learning and e-Learning based SCORM (SCORM 기반 u-Learning과 e-Learning 비교연구)

  • Choi, Sung;Ryu, Gab-Sang
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2006.06a
    • /
    • pp.495-505
    • /
    • 2006
  • IT기술기반 교육시스템은 인터넷 등장 이전에도 가능성을 인정받아 지속적으로 개발되어 온 분야이며, 교육공학과의 연계로 지식 전날의 이론체계로 각광을 받고 있다. 사이버교유도 인터넷이전부터 다양한 통신방법을 응용하여 개발되었고, 최근 인터넷을 통하여 사이버 교육시스템은 완벽한 기술기반을 갖추게 되였다. 그러나 IT기술의 급격한 변화로 사이버교육시스템은 계속하여 신기술 변화에 적용해야만 한다. 현재 정보통신기술의 변화는 방송 통신망의 융합, 브로드 밴드 네트워킹, 스마트 디바이스의 다양화, 멀티미디어 기술의 고도화로 요약된다. 이 기술의 종합한 작용으로 유비쿼터스 사회의 기반으로 진화되고 있다. 그래서 e-Learning 분야도 기존 인터넷기반 시스템과는 달리 차세대 온라인교육시스템으로 친화되고 있다. IT융합가술 기반의 온라인 교육시스템은 각종 국제표준단체에서 표준안이 제시되고 있다. e-Learning 시스템이란 선기술 기반을 반영한 표준기술을 사용하는 온라인교육시스템을 포괄하는 개념이다. 본 연구에서는 e-Learning 시스템과 유비쿼터스 기술을 반영한 e-Learning을 비교하였다. 그리고 u-Learning 시스템의 기술정립과 EOD(Education On Demand) 시스템에 대하여 연구하였다. 1. u-Learning 정의 정보산업분야를 비롯한 문화, 교육 등 모든 분야에서 유비퀴터스라는 수식어가 붙어 다니고 있다. e- Learning 교육 업계에 따르면 10년 후에는 유비쿼터스는 대중화가 될 것이며, 부가가치 규모는 100조 원에 이를 것으로 추정된다. 그래서 교육산업도 주변 환경이 아날로그 방식에서 IT 기반에 의한 디지털 환경으로 변화되고 있다. 또한 e러닝, T러닝, m러닝, u러닝 등의 용어가 생성되고 있다.키지에어컨에서 사용되고 있는 밀폐형 압축기에 대해서 그림 2에서 나타내고 있는 냉방능력 10tons(120,000Btu/h) 이하를 중심으로 상기의 최근 기술 동향을 간략하게 소개하고자 한다.질표준의 지표성분으로 간주되는 진세노사이드의 절대함량과 그 성분조성 차이에 따른 임상효과의 차별성이 있는지에 대한 검토와, 특히 최근 실험적으로 밝혀지고 있는 사포닌 성분의 장내 세균에 의한 생물전환체의 인체 실험을 통한 효과 검정이 필요하다. 나아가서는 적정 복용량의 설정과 이와 관련되는 생체내 동태 및 생체이용율(bioavilability)에 관한 정보가 거의 없으므로 이것도 금후 검토해야 할 과제로 사료된다. 인삼은 전통약물로서 오랜 역사성과 그동안의 연구결과에 의한 과학성을 가지고 있으므로 건강유지와 병의 예방 및 회복촉진을 위한 보조요법제 또는 기능성 식품으로써의 유용성이 있는 것으로 판단된다. 앞으로 인삼의 활용성 증대를 위해서는 보다 과학적인 임상평가에 의한 안전성 및 유효성 입증과 제품의 엄격한 품질관리의 필요성이 더욱 강조되어야 할 것이다.xyl radical 생성 억제 효과를 보여 주었다. 본 실험을 통하여 BHT 를 제외하고 전반적으로 세포 수준에서의 oxidative stress 에 대한 억제 효과를 확인해 볼 수 있었으며 특히 수용성 항산화제들에서 두드러진 효과를 보여 주었다. 제공하여 내수기반 확충에도 노력해야 할 것 이다.있었다., 인삼이 성장될 때 부분적인 영양상태의 불충분이나 기후 등에 따른 영향을 받을 수 있기 때문에 앞으로 이에 대한 많은 연구가 이루어져야할 것으로 판단된다.태에도 불구하고 [-wh]의미의 겹의문사는 병렬적 관계의 합성어가 아니라 내부구조를 지니지 않은 단순한 단어(minimal $X^{0}$<

  • PDF

Study on the energy-saving constant temperature and humidity machine operating characteristics (에너지 절감형 항온항습기 운전 특성에 관한 연구)

  • Cha, Insu;Ha, Minho;Jung, Gyeonghwan
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.27-33
    • /
    • 2016
  • The heat recovery system that was applied in this study, is the energy-saving type that can produce the maximum cooling capacity less power in use. In order to have a more precise control function the temperature and humidity of the constant temperature and humidity machine, control algorithm is applied to designed a fuzzy PID controller, and the outside air compensation device (air-cooled) demonstrated excellent ability to dehumidify the moisture, $-20^{\circ}C$ in winter. High efficiency and the low-noise type sirocco fan operate quitely and designed to fit the bottom-up and top-down in accordance with the characteristics of equipment. as a result of experiment data, the conversion efficiency is 95% or more, power recovery time is within 5sec, stop delay time is within 30sec, pump down time is 10sec, pump delay time is 5sec, heating delay time is 5sec, temperature deviation is ${\pm}2^{\circ}C$ (cooling deviation: $2^{\circ}C$, Heating deviation : $2^{\circ}C$), humidity deviation is a ${\pm}5%$ (humidification deviation 3.0%, dehumidification deviation 3.0%). Recently, ubiquitous technology is important. so, the constant temperature and humidity machine designed to be able to remotely control to via the mobile phone, and more scalable to support MMI software and automatic interface. Further, the life of the parts and equipment is extended by the failure.