• 제목/요약/키워드: 냉방기

검색결과 289건 처리시간 0.028초

파울링 형성 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 실험적 연구 (An Experimental Study of the Air-side Particulate Fouling of Finned-Tube Heat Exchangers of Air Conditioners by using Accelerated Particle-Loading System)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱;옥주호
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.802-808
    • /
    • 2003
  • The air-side particulate fouling of the HVAC heat exchangers degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. The purpose of this study is to investigate the fouling characteristics using accelerated particle loading system. The fouling characteristics are analyzed as functions of a dust concentration, a face velocity and a wet or dry surface condition. The pressure drop increases with increasing test operation and reaches constant asymptotic level. For the saturated condition due to particle loading, the pressure drop across the slitted finned-tube heat exchangers at the face velocity of 1 m/sec increases up to 57% and the cooling capacity decreases about 2%. The cooling capacities are not affected greatly by the presence of the fouling deposits if the thickness of the fouling deposits can not change substantially the flow pattern through the fins.

외기 전용 공조기의 성능 분석 및 현장 성능시험 (The Performance Analysis and On-site Performance Test of a Dedicated Outdoor Air System)

  • 김영일;김정민;정광섭;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.346-351
    • /
    • 2007
  • Dedicated outdoor air(DOA) system which conditions the outdoor air separately is superior to conventional cooling+reheating system with respect to energy consumption and indoor comfort. Since the sensible and latent load characteristics of indoor and outdoor are different, it is more efficient to treat them separately. In this study, cycle analysis and on-site performance test of DOA system have been conducted. The study shows that DOA requires 48.8% less equivalent energy that conventional system. The on-site performance test of the prototype shows that the coefficient of performance(COP) of the DOA system is 37.4% higher than the conventional system.

  • PDF

수용가 냉방부하를 고려한 하절기 주상변압기 최대부하 추정 (Peak Load Estimation of Pole-Transformer in Summer Season Considering the Cooling Load of Customer)

  • 윤상윤;김재철;김기현;임진순
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, we propose a method for estimating the peak load of pole-transformer in summer season considering the degree of cooling load possession in customer. The cooling load of customer is selected as the most reliable parameter of peak load in summer season. The proposed estimation method is restricted to the aspect of load management for pole-transformer. The main concept of proposed method is that the error of peak load estimation using load regression equation reduces with considering the degree of cooling load possession in customer. We propose an index for estimation of cooling load possession in each customer. The proposed index is defined as cooling load possession in customer (CLPC) and obtained from the increment of monthly electric energy. The membership function for deciding the uncertainty of cooling load possession in customer is used. The database of pole-transformer in Korea Electric Power Corporation (KEPCO) is used for case studies. Through the case studies, we verify that the proposed method reduces the error of peak load estimation than the conventional method in domestic.

  • PDF

냉각식 시스템과 비교한 복합식 제습냉방시스템의 냉각 열량증가에 관한 실험적 연구 (Study on the Energy Efficiency Improvement of Hybrid Dehumidification Air Conditioning System Compared with Refrigeration System)

  • 이수동;박문수;정진은;최영석
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.952-959
    • /
    • 2004
  • The hybrid liquid desiccant air conditioning system has been in use for many years, primarily in industrial process applications requiring dehumidification and humidity control. In this study, the hybrid dehumidifier has been designed to study the dehumidification characteristic of the aqueous triethylene glycol (TEG) solution. The experimental results show energy efficient characteristics of hybrid liquid desiccant air conditioning system compared with the refrigeration system in terms of energy use, the difference of pressure loss between hybrid liquid desiccant air conditioning system and refrigeration system. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

2단압축 이산화탄소 사이클의 냉방성능 향상 특성에 대한 실험적 연구 (Experimental Study on the Cooling Performance Improvement of a Two-stage Compression $CO_2$ Cycle)

  • 조홍현;이호성;김용찬
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.835-841
    • /
    • 2006
  • A $CO_2$ system using the two-stage compression cycle was tested by varying $1^{st}-2^{nd}$ compressor frequencies in the cooling mode. To improve the cooling performance of the two-stage compression $CO_2$ cycle, the following cycle options were applied: a basic cycle, a cycle with an intercooler, a cycle with an IHX (internal heat exchanger), and a cycle with an intercooler and IHX. The cycle with the intercooler-IHX showed the highest cooling capacity improvement among the cycle options at all compressor frequencies. The cycle with the intercooler, the cycle with the IHX, and the cycle with the intercooler-IHX improved the cooling COP by 7, 12, and 15%, respectively, over the basic $CO_2$ cycle when the compressor frequencies for the first and second compressors were 50 Hz and 30 Hz, respectively. In addition, the applications of the selected cycle options enhanced system reliability.

선박용 흡수식 냉동기의 냉매적용 냉각 시스템 성능 분석 (Performance analysis of a cooling system with refrigerant in a marine absorption refrigerator)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.282-287
    • /
    • 2016
  • 최근 조선사들은 선박이 운항되는 연안 환경의 개선과 보호를 위하여 $CO_2$를 절감할 수 있는 친환경 선박과 함께 선박 운항 중 소비하는 에너지의 절감을 위한 고효율화 선박 개발의 노력도 활발하게 수행하고 있다. 본 연구에서는 전기로 구동되는 선박의 증기압축식 냉동기 대신에 선박 엔진 자켓수의 폐열을 이용하여 냉방을 할 수 있는 흡수식 냉동기의 적용 가능성과 냉각시스템에 냉매를 적용하는 시스템의 성능을 분석하였다. 연구결과, 해수와 열교환하여 액화될 수 있는 냉매들 중 R236fa가 가장 적합한 냉매로 분석되었으며, 이를 적용한 흡수식 냉동기의 COP는 0.798로 육상의 냉각탑을 이용한 수랭식보다 15% 그리고 해수 열교환기식 수랭식보다 5% 향상되었다. 냉동능력 1RT를 얻기 위한 LiBr 흡수용액 순환량은 0.013 kg/s로 수랭식 보다 25% 이상 감소하며, 냉각 매체 순환량도 수랭식의 15.7%에 불과한 매우 효과적인 냉동기가 되었다. 해수온도가 $18^{\circ}C$ 이하로 낮으면 발생하게 되는 LiBr의 결정화는 재생기에서 배출되는 엔진 자켓수의 온도를 이용하여 해수 온도를 상승시킴으로써 방지할 수 있다.

흡수식냉난방기용 다성분 리튬염 작동매체의 증기압 및 용해도 측정 (Measurement and Analysis on the Physical Properties of Multi Lithium Salts Solution in Absorption Heat-Pumps)

  • 주우성;김희택;오영삼;백영순
    • 공업화학
    • /
    • 제9권1호
    • /
    • pp.82-88
    • /
    • 1998
  • 고효율 공냉형 흡수식 냉방기를 위한 신작동매체로 기존의 $LiBr-H_2O$계에 높은 흡수성과 용해성를 지닌 $LiNO_3$과 LiCl 무기물을 각각 첨가하여 제조하였다. 본 연구를 통하여 제조된 다성분계의 작동매체에 대한 용해도와 증기압을 측정하여 $LiBr-H_2O$계와 비교 분석하였으며, 이들에 대한 최적혼합비를 각각 구하였다. 용해도 측면에서 $LiBr-LiNO_3-H_2O$계의 경우, LiBr과 $LiNO_3$의 최적혼합 몰비는 5:1이었으며, 반면 $LiBr-LiNO_3-LiCl-H_2O$계의 경우 LiBr, $LiNO_3$, LiCl의 최적혼합몰비는 5:1:2로 나타났다. 한편 증기압은 $LiBr-H_2O$계에 $LiNO_3$의 첨가량이 증가하였으나, LiCl의 경우에는 첨가량이 증가함에 따라 감소하는 경향을 각각 나타내었다.

  • PDF

태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구 (Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System)

  • 김광호;최광환;금종수;김보철;김종렬
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.45-53
    • /
    • 1999
  • 본 논문은 태양열을 구동원으로 하고 액체흡수제인 염화리튬(LiCl) 용액을 이용하여 제습/냉방 및 난방을 하나의 시스템으로 이루는 태양열 이용 냉난방 공조시스템 중 여름철 전열교환기의 제습/냉방에 관한 성능실험 결과이다. 여름의 고온다습한 실내공기는 휀에 의해 전열교환기로 유입되어 충진층에서 살수된 LiCl 용액과 직접 접촉하여 제습/냉각된 후, 건조공기로 바뀌어 실내로 취출된다. 한편 수분을 흡수하여 저농도 용액으로 변한 LiCl 용액은 재생기에서 태양열에 의해 다시 고농도 용액으로 바뀌어 흡수포텐셜을 갖는다. 본 실험에서는 형상 및 크기가 다른 3가지 충진재를 사용하여 전열교환기의 제습성능을 비교하였으며, 절대습도기준 총괄 물질전달계수인 $k_xa(kg/m^3h{\Delta}x)$로써 그 성능을 평가하였다. 특히 $k_xa$값은 액체흡수제 유량, 공기 풍량, 충진재 형상 및 충진층 높이에 따라 변한다. 따라서 이에 대한 영향을 조사하기 위하여 여러 가지 실험한 결과, 풍량은 $k_xa$값에 미치는 영향이 컸으나, 유량은 그다지 영향을 미치지 않음을 알 수 있었다. 또한 충진재의 형상에 따른 비교 실험에서 충진재의 직경이 큰 경우에는 충진층 높이의 영향이 컸으나, 직경이 작은 경우에는 높이에 의한 영향이 직경이 큰 경우보다 작았다. 이상의 실험 결과로부터 $k_xa$값을 충진재 형상 및 충진층 높이에 따라 정지하면 최적 전열교환기 설계 및 제작에 기초자료로 활용할 수 있음을 알았다.

  • PDF

파라핀을 이용한 건축용 시트형 잠열축열재의 축열특성에 관한 실험적 연구 (An Experimental Study on the Heat Storage Properties of Phase Change Material Using Paraffin Sheets in Building)

  • 고진수;김병윤;박성우
    • 한국건축시공학회지
    • /
    • 제11권5호
    • /
    • pp.435-441
    • /
    • 2011
  • 기 발표된 보고서에 따르면, 철근콘크리트 건축물을 전과정 평가 한 결과, 온실가스가 신축과 해체 등을 제외한 냉 난방 사용의 유지관리 단계에서 전체 발생량의 70 % 이상 배출한다고 보고하였다. 이는 건축물로 인한 온실가스 배출량을 줄이기 위해서는 유지관리 단계가 중요하고, 건축물의 설계단계 부터 에너지 소비를 최소화할 수 있는 유지관리 계획이 필요함을 의미한다. 따라서, 본 연구에서는 건축물의 사용단계에서 냉방에너지 소비를 줄일 수 있는 방법으로 상변화물질(Phase Change Material)인 파라핀 시트를 건축물의 개구부 또는 벽체 마감재로의 활용 가능성을 검토하였다. 온도조절이 가능한 챔버 내부에 파라핀 시트를 적용한 축열실과 적용하지 않은 일반실을 제작하고, 대류와 직사일광의 조건으로 각각 챔버 온도를 상승시켜 실험체 내부의 온도변화를 측정하였다. 실험 결과, 파라핀 시트를 적용한 모든 조건의 실험체에서 상변화 온도인 $26^{\circ}C$ 전후에서, 일반실보다 $1{\sim}3^{\circ}C$정도의 실내온도 상승을 지연시키는 것으로 나타났다. 결론적으로 외부 에너지가 상변화에 소비되어 온도변화가 없는 잠열축열재를 건축물 마감재로 활용함으로써, 여름철 실내 냉방 에너지 소비를 줄일 수 있다는 사실을 확인하였다.

열 영상과 퍼지 제어 기법을 이용한 온도 및 풍향 제어 (Control of Temperature and the Direction of Wind Using Thermal Images and a Fuzzy Control Method)

  • 김광백;조재현;우영운
    • 한국정보통신학회논문지
    • /
    • 제12권11호
    • /
    • pp.2083-2090
    • /
    • 2008
  • 본 논문에서는 에너지 절약을 위한 방법으로 냉방기의 적정 온도 및 풍향을 제어하기 위하여 열 영상과 퍼지 추론 규칙을 적용한 온도 및 풍향 제어 기법을 제안한다. 온도 제어를 위한 시뮬레이션에서는 열 영상을 분석하기 위해서 영상을 $300{\times}400$의 크기를 가지는 색상 분포 영상으로 변환한다. 색상 분포 영상은 Red, Magenta, Yellow, Green, Cyan, Blue의 온도 값을 가지는 R,G, B 값으로 구성된다. 각 색상은 $24.0^{\circ}C$에서 $27.0^{\circ}C$의 분포의 온도 값을 가지며, 색상 분포 영상은 레벨 1에서 레벨 10의 높이 계층으로 분류한다. 분류된 각 계층은 고유의 색상 분포도를 가지며 색상이 가지는 온도 수치에 따라 계층별로 온도 값이 할당된다. 실내 공간의 전체적인 온도의 균형과 풍향을 제어하는 과정은 다음과 같다. 풍향의 방향 및 지속 시간, 그리고 풍향의 강도를 구하기 위한 색상 분포 영상의 온도 및 높이 값을 적용하여 퍼지 소속 함수를 설계한 후, 소속 함수의 소속도를 구하고 퍼지 추론 규칙을 적용하여 풍향의 강도를 구한다.