• Title/Summary/Keyword: 냉방기

Search Result 289, Processing Time 0.026 seconds

A Study on the Vibration Reduction of Pipe Line in the Air Conditioner for Railway Vehicles (철도차량용 냉방기 배관진동 저감 연구)

  • Jung, Yong-Ho;Koo, Jeong-Seo;You, Won-Hee
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.574-579
    • /
    • 2011
  • In this study, we suggested a design modification method to reduce the vibration of an air conditioner for railway vehicles and increase the durability of its pipe lines. Through experimental vibrational mode analyses and structural modifications on the air conditioning system, vibration reduction scheme was suggested and evaluated its effectiveness by empirical modal analysis. The derived design idea was applied to a real air conditioning system and the expected improvement was obtained.

  • PDF

국가 최대 전문교육훈련기관의 냉난방시설 ESCO사업으로 환골탈태

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.18
    • /
    • pp.18-21
    • /
    • 2002
  • 국가전문행정연수원은 지난해 8월부터 올 6월까지 약 10개월에 걸쳐 기존의 노후화된 증기난방 보일러와 개별 냉방기를 흡수식 냉온수기를 통한 중앙집중식 냉난방으로 전환하는 ESCO사업을 실시해 막대한 에너지 절감 효과를 보고 있다. 총 4개 건물을 대상으로 진행된 이번 냉난방 ESCO사업은 총 사업금액이 6억2천여만원에 이르며 연간 절감되는 에너지절감금액이 약 1억4천4백만원 정도여서 앞으로 5년 10개월에 걸쳐 모든 투자비가 회수될 예정이다.

  • PDF

Cooling Efficiency and Growth of Tomato as effected by Root-zone Cooling Methods in Summer Season (고온기 근권 냉방방식에 따른 냉방효율과 토마토 생육에 미치는 영향)

  • 이재한;권오근;최영하;박동금;권준국
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.130-133
    • /
    • 1999
  • 우리나라의 시설재배는 비가림 형태에서 많은 자본과 기술이 투자된 현대화 고정시설로 발전해가고 있으며 면적도 증가하고 있다. 시설의 활용면에서는 주로 동절기에 집중되어 있고, 하절기에는 최고기온이 3$0^{\circ}C$ 이상되는 날이 2-3개월 정도로 시설내 작물재배는 거의 불가능한 실정이다. 따라서 하절기에는 대부분 휴작함으로서 시설의 주년이용에 문제점으로 대두되고 있다. (중략)

  • PDF

Effect of Root-zone Local Cooling on Seedling Growth of Tomato (근권부 국부 냉방이 토마토 묘 생육에 미치는 영향)

  • Kim, Eun Ji;Hwang, Hyunseung;Ju, Se Hun;Na, Haeyoung
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.286-291
    • /
    • 2022
  • The effect of root-zone local cooling on seedling growth of tomato was investigated. Lower pipe cooling was used for local cooling of the root zone, and the root zone temperature was set at 20 and 25℃. There was no difference in plant height, root length, and leaf number according to local cooling temperature. Leaf area, fresh weight, dry weight, and chlorophyll content of the shoot and root was higher in the 25℃ than those of 20℃ at 28 DAS. These results showed that cooling for seedling growth of tomato 25℃ is sufficient considering energy efficiency. This study will be helpful in the development of local cooling technology that can reduce the energy required for cooling during the production of tomato seedlings in the high temperature season.

An Expert System for Air-conditioner Design (냉방기 설계를 위한 전문가시스템)

  • 김상호;명세현;한순홍
    • Journal of Intelligence and Information Systems
    • /
    • v.3 no.1
    • /
    • pp.83-99
    • /
    • 1997
  • 냉방기인 에어컨디셔너에 대해 기존의 설계방법과 지식, 그리고 경험을 체계화하고, 설계 제한 조건에 따른 최적설계 기법을 도입한 전문가시스템을 구현한다면, 적은 데이터 입력으로 주어진 설계 조건에서의 최적 해를 시간 낭비 없이 얻을수 있고, 설계자 간의 설게 능력 차이에 의한 상이한 결과도 해소할 수 있으므로 경제적인 설계가 중심에서 전문가시스템 중심으로 축적되는 것이 가능해져, 설계자의 이동에 따른 설계 지식의 누수를 방지할 수 있고, 설계 지식이 별도의 지식베이스에 구축되어 있으므로 보수 관리도 용이하게 되어 설계 지식의 지속적인 발전과 집적을 도모할 수 있다. 현장에서 사용중인 에어컨 설계용 소프트웨어를 기초로 실제 실무에서 접할 수 있는 설계 제약 조건에 대해서, 최적설계 기법의 적용과 지식베이스 구축을 통해 경제적인 설계가 가능한 설계 전문가시스템을 개발하였다.

  • PDF

The performance evaluation of outdoor unit cooling system in a residential apartment complex (주상복합의 실외기 형태에 따른 냉방시스템 성능 평가)

  • Kyung, Seo-Kyung;Kim, Yun-Jin;Lim, Jung-Hee;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

A Study on Cooling Systems with Cold Water Panels in the Walls of Small Buildings (소형 건축 벽면의 냉수 패널에 의한 냉방시스템에 관한 연구)

  • Cho, Dong-Hyun;Jo, Myeong-Gi
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.20-26
    • /
    • 2019
  • This study was conducted on cooling systems in which, for the first time at home and abroad, cold water panels are embedded in the walls of small buildings for radiant cooling by heat absorption with cold water. In summer, cold water is circulated through cold water (chiller) circulation tubes embedded in three walls (two side walls and one rear wall) of a building to implement radiant cooling by the coldness of the water. From the results of this study, the experimental and theoretical natural convection heat transfer coefficients were relatively well-matched over the entire experimental range, thereby verifying the reliability of the experimental results. The surface temperature reduction rate of the walls in which cold water panels are embedded was large whereas that of the walls where no cold water panels are embedded was very small.

CES(Community Energy Supply System) 사업

  • 박용순;정용우
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.1
    • /
    • pp.57-67
    • /
    • 2000
  • 최근 국민소득수준의 향상을 따라 여름철 전력 수요가 폭증하므로 전력안정 공급을 위한 특별 대책이 필요한 실정이고 환경적인 측면이나 수용가 입장에서 만족스러운 새로운 냉·난방, 전기 공급시스템의 개발·적용이 필요하다. 선진국의 경우, 소규모의 집단에너지 공급이 주류를 이루고 있으며 특히 소규모 열병합 발전시 생산되는 전기, 지역난방열 이외에 냉방에 필요한 냉수를 중앙열원에서 동빌딩을 중심으로하는 구역형 집단에너지 시스템(Community Energy Supply System)등 소규모지역 난냉방 공급방식이 활성화되어 있으므로, 우리나라에서도 냉방/난방/전기부하 패턴 및 하절기 피크부하 경감에 대한 기여도 등을 고려한 경제성있는 최적시스템 구성이 가능한지 검토할 필요가 있다. 소규모 집단에너지사업은 대규모 사업과는 달리 적정 수요예측이 가능하므로 효율적인 초기 투자가 이루어질 수 있으며, 상업용 및 사업용 빌딩 등을 중심으로 부하밀도가 높은 구역을 대상으로 하명서 해당 부하패턴에 적합한 효율적인 시스템의 구성을 통해 수익성이 확보된다면 국가 에너지절약 및 한전의 여름철 전력 피크부하 경감, 대기 환경공해 감소, 도심 도시미관 향상 등의 사업효과가 기대된다. 본문에서는 이러한 소규모 집단에너지시스템 개요 및 국내외 공급 현황, 국내 적용환경, 적용 가능에너지 검토 열원시스템의 기본방향 등에 대하여 언급하고자 한다.

  • PDF

A Study on the Efficiency Enhancement of the HT-PEMFC Having Fuel Processing System by Connecting Adsorption Chilling System (흡착식 냉방 시스템을 이용한 수소개질/연료전지 시스템의 효율향상)

  • NASEEM, MUJAHID;KIM, CHUL-MIN;LEE, SANGYONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.5
    • /
    • pp.411-417
    • /
    • 2019
  • An adsorption chiller is connected to the fuel processing/fuel cell system to increase the energy efficiency of the system. Since, the minimum temperature of $70^{\circ}C$ is needed to operate the adsorption chiller, HT-PEMFC is used as a heating source and $80^{\circ}C$ hot water in the water tank at the system is supplied to the chiller. Experimentally measured COP of the adsorption chiller was between 0.4-0.5 and the total calcuated efficiency of the connected system was between 60% and 70% comparing to 47% without adsorption chilling system.

Study on Indoor Thermal Environment Controlled by Portable Cooler (실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토)

  • Choi, Dong-Kyun;Song, Doosam;Kim, Jung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.