• 제목/요약/키워드: 냉동성능

검색결과 382건 처리시간 0.023초

어선용 수평 냉각판 냉동장치의 냉동 효율 개선에 관한 연구 (A Study on Freezing Efficiency Improvement of Horizontal-Plate Freezer for Fishing Vessel)

  • 이재철;정지호;김병목;신성철;김수영;정보용
    • 대한조선학회논문집
    • /
    • 제52권1호
    • /
    • pp.19-24
    • /
    • 2015
  • The economic efficiency for fishery products can be related to their freshness and the quality. In order to freshly storage the product, freezing equipment system is necessary for fishing vessels. For this purpose, the horizontal plate freezer (HPF) is mostly used. In this research, our major objective is to improve the freezing performance of the HPF. Therefore, it is important to analyse the relationship between the shape of channels and the cooling temperature of the HPF. In order to save calculation time while checking the trend analysis between shape and performance, we used scaled models, and evaluate the cooling temperature of full scale model based on trend analysis results. The produced HPF in domestic was used, and the same operating conditions are considered. Based on this paper, the future research will be a comparison and verification through the experiments.

PCA 및 변수 중요도를 활용한 냉동컨테이너 고장 탐지 방법론 비교 연구 (A Comparative Study on the Methodology of Failure Detection of Reefer Containers Using PCA and Feature Importance)

  • 이승현;박성호;이승재;이희원;유성열;이강배
    • 한국융합학회논문지
    • /
    • 제13권3호
    • /
    • pp.23-31
    • /
    • 2022
  • 본 연구는 H해운사에서 제공받은 Starcool사의 실제 냉동 컨테이너 운영데이터를 분석하였다. H사의 현장 전문가와 인터뷰를 통해 4가지 고장 알람 중 Critical 및 Fatal Alarm만 고장으로 정의하였고, 냉동 컨테이너 특성상 모든 변수를 사용하는 것은 비용측면에서 비효율을 초래하는 것을 확인하였다. 이에 본 연구는 특성 중요도 및 PCA 기법을 통한 냉동 컨테이너 고장 탐지 방법을 제시한다. 모델의 성능 향상을 위해 XGBoost, LGBoost 등과 같은 트리계열 모델을 통해 변수 중요도(Feature Importance)를 기반으로 변수 선택(Feature selcetion)을 하고 선택되지 않은 변수는 PCA를 사용하여 전체 변수의 차원을 축소시켜 각 모델별로 지도학습을 수행한다. 부스팅 기반의 XGBoost, LGBoost 기법은 본 연구에서 제안하는 모델의 결과가 62개의 모든 변수를 사용한 지도 학습의 결과보다 재현율(Recall)이 각각 0.36, 0.39씩 향상되는 되는 결과를 보였다.

R-404A를 사용하는 소프트 아이스크림 제조기의 냉매 충전량 및 팽창 밸브 개도 최적화 (Optimization of the Refrigerant Charge and the Expansion Valve Opening for the Soft Ice Cream Machine Using R-404A)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.728-734
    • /
    • 2016
  • 최근 들어 국민 식생활 문화가 개선되고 생활수준이 향상됨에 따라 소프트 아이스크림, 슬러시와 같은 일회용 냉동 유제품의 소비가 급증하고 있다. 이들 냉동 유제품은 소형 냉동 시스템에서 만들어진다. 소프트 아이스크림 제조기의 냉매로 그간 R-502가 주로 사용되어 왔으나 오존층 파괴와 관련하여 R-404A로 대체되고 있다. 본 연구에서는 냉각기 체적 2.8 리터인 R-404A를 사용하는 소프트 아이스크림 제조기에 대하여 최적화와 성능평가를 수행하였다. 최적화는 적정 냉매량 및 팽창 밸브의 개도를 찾는데 주안점을 맞춰 수행되었다. 최적 조건에서 아이스크림 제조 시간은 10분 5초, COP는 0.57로 나타났다. 이 제품에 대하여 무 간격 연속 판매 시험, 30초 간격 연속 판매 시험, 극한 시험을 수행하여 성능을 평가하였다. 무 간격 연속 판매는 20개까지 가능하였고 30초 간격 연속 판매는 무한대로 가능하였다. 또한 여름철 및 겨울철 환경에도 아이스크림 판매가 가능한 것으로 나타났다. 본 연구 결과는 냉동식품 제조기를 비롯한 여타 냉동 사이클의 최적화에도 활용될 수 있을 것이다.

착용형 개인 냉방시스템 개발 (Development of the Wearable Personal Cooling System)

  • 장준영
    • 한국산학기술학회논문지
    • /
    • 제13권7호
    • /
    • pp.2872-2877
    • /
    • 2012
  • 본 논문은 더위나 고온의 환경에서 열적스트레스를 줄이기 위한 착용형 개인 냉방시스템 개발에 관한 것이다. 개인 냉방시스템은 냉매압축 냉동사이클로 작동되는 소형 냉동시스템이 적용되었다. 소형 냉동시스템은 이동과 착용이 가능하도록 소형화와 경량화에 맞게 구성되었다. 증발기는 나일론튜브를 사용하여 조끼 내부에 매립하여 열전도에 의해 신체 열을 저감시키는 직접냉각방식이 적용되었다. 착용형 개인 냉방시스템은 냉방능력은 대략 100W이며 주위온도보다 12~$13^{\circ}C$ 정도 낮게 유지되는 성능을 가진다. 착용형 개인 냉방시스템의 무게는 조끼, 케이스, 배터리를 포함하여 약 3kg이다.

사무소 건물에서 냉동기의 대수제어를 통한 냉동기 거동 특성 및 에너지 절감 효과 분석 (Detailed Analysis on Operation Characteristics and Cooling Energy Saving Effect of Chiller Staging in an Office Building)

  • 서병모;손정은;이광호
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.137-144
    • /
    • 2016
  • Commercial buildings account for a significant proportion of the total building energy use in Korea, and cooling energy, in turn, accounts for the largest proportion of total energy consumption in commercial buildings. Under this circumstance, chiller staging is considered to be a reasonable and practical solution for cooling energy saving. In this study, the part-load ratio and the operating characteristics of a vapor compression chiller were analysed within an office building. In addition, energy consumption among different chiller staging schemes was comparatively analysed. As a result, significant proportions of total operating hours, cooling load and energy consumption turned out to be in the part load ratio range from 0% through 50%, and thus energy consumption was significantly affected by the chiller COP at low part-load conditions, indicating that the chiller operation at the part-load is an important factor in commercial buildings. In addition, utilizing a sequential chiller staging scheme can reduce the annual cooling energy usage by more than 10.3% compared to operating a single chiller.

2단압축 냉동장치의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristics of Two-Stage Compression Refrigeration Systems)

  • 김재돌;오후규;김성규;권옥배
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권2호
    • /
    • pp.25-32
    • /
    • 1994
  • The characteristics of the R-22 two-stage compression refrigeration systems were investigated. The apparatus consisted of 0.5HP and 1HP hermetic reciprocating compressors for the high and low stage sides respectively, a condenser, an evaporator, a heat exchanger, four expansion valves, and two intercoolers. The experiments covered a range of refrigerant flow rates from 24 to 84kg/h, and the inlet temperature of cooling water in the condenser and heat source water in the evaporator ranged from 20 to 30$^.\circ}C$The results Showed that the refrigerant flow rate had greater effect on the refrigerating capacities, the compression efficiency and the coefficient of performance of two-stage compression systems than the inlet temperature of heat source water. And all these values were decreased with increasing inlet temperatures of the cooling water. The pressure drops in the evaporator of two-stage compression systems were decreased in proportion to the increase in the inlet temperature of the heat source and cooling water, but it was increased by the refrigerant flow rate.

  • PDF

빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구 (In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System)

  • 신영기;양훈철;태춘섭;조수;김영일
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.

인터쿨러와 공랭식 응축기를 동시에 사용하는 냉방-냉동 겸용 캐스케이드 사이클에 대한 연구 (A Study on the Cascade Hybrid Cooling/Refrigeration Cycle Equipped With Intercooler and Air-Cooled Condenser in Series)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제20권7호
    • /
    • pp.353-362
    • /
    • 2019
  • 그간 캐스케이드 냉동 시스템에 대해서 열역학적 해석은 다수 수행되었으나 증발기, 응축기, 인터쿨러 등 부품 해석을 통한 시스템 평가는 미진한 상태이다. 본 연구에서는 냉방 및 냉동 열교환기가 별도로 장착되어 있고 하부 사이클에 공랭식 응축기와 인터쿨러가 직렬로 연결되어 있는 캐스케이드 냉동 사이클에 대해 성능 해석을 수행하였다. 우선 증발기, 응축기, 인터쿨러 등 요소부품에 대해 모델링을 수행하고 R-410A를 사용하는 냉방 능력 8 kW, 냉동 능력 15 kW의 캐스케이드 냉동 사이클의 요소 부품의 - 상부 응축기, 하부 응축기, 냉방 증발기, 냉동 증발기, 인터쿨러, 압축기, 전자팽창변 - 설계를 수행하였다. 설계 사양에 대하여 외기 온도를 $26^{\circ}C$에서 $38^{\circ}C$로 변화시키며 해석을 수행한 결과 냉각 열량은 하부 증발기에서는 거의 일정하고 상부 증발기에서는 9% 감소, 인터쿨러에서는 63% 증가하였다. 한편 COP는 외기 온도의 증가에 따라 감소하였다. 인터쿨러가 작동하지 않는 사이클 대비 인터쿨러 사이클이 COP 측면에서 우위를 보였다. 또한 상부 응축기의 크기를 당초 설계치의 2배 증가시키면 하부 증발기 열량은 변함이 없는 반면 상부 증발기 열량은 4% 증가하였다. 한편 상부 응축기의 크기 증가에 따라 상부 사이클의 COP는 증가하는 반면 하부 사이클의 COP는 큰 변화가 없다. 또한 하부 응축기 크기를 2.8배 증가시키면 상하부 증발기의 열량 변화는 거의 없고 인터쿨러의 열량만이 8% 감소하였다. 아울러 하부 사이클의 COP는 응축기의 크기가 증가함에 따라 다소 증가하였으나 상부 사이클의 경우는 그 변화가 미미하였다.

대체냉매를 적용한 대형 압축식 냉동기의 만액식 증발기에 대한 성능 해석 (Performance Analysis of the Flooded Refrigerant Evaporators for Large Tonnage Compression-Type Refrigerators Using Alternative Refrigerants)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.18-25
    • /
    • 2016
  • 대형 압축식 냉동기의 증발기 전열관으로는 그간 평활관이 주로 사용되어 왔으나 최근들어 비등 성능이 우수한 성형 가공관을 많이 사용하고 있다. 증발기는 관군으로 구성되고 따라서 증발기 내 위치에 따라 냉매 상태가 다르다. 특히 R-11, R-123과 같은 저압 냉매는 압력변화에 따른 포화온도 변화가 크므로 위치에 따라 포화온도가 다르게 된다. 따라서 증발기를 적절히 설계하려면 증발기 내 각 위치에서의 냉매의 상태를 적절히 예측하여야 한다. 본 연구에서는 대형 냉동기의 만액식 증발기를 모사할 수 있는 컴퓨터 프로그램을 개발하였다. 이 프로그램은 증발기를 미소 체적으로 구분하고 각 미소 체적에 적절한 관 내외측 열전달 및 압력손실 상관식을 적용하여 해석을 수행하였다. 본 프로그램을 R-123을 사용하는 T사의 만액식 증발기 해석에 적용한 결과 만족할 만한 결과를 얻었다. 이 프로그램을 이용하여 신 냉매인 R-123, R-134a를 사용하는 만액식 증발기의 해석을 수행하였고 특히 관군 세장비의 영향을 검토하였다.

LNG 열교환기의 압력강하에 따른 천연가스 액화용 초저온 캐스케이드 냉동사이클 특성 (Characteristics of Cryogenic Cascade Refrigeration Cycle for Liquefaction of Natural Gas with the Pressure Drop of Heat Exchanger)

  • 윤정인;최광환;손창효;곽진우;백승문
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.756-761
    • /
    • 2012
  • 천연가스는 $-160^{\circ}C$까지 냉각 및 액화되어 액화천연가스(LNG)가 되고, 이때 LNG의 체적은 천연 가스의 1/600로 줄어든다. 이로 인해 LNG는 수송시에 이점이 있다. 본 연구에서는 천연가스 액화용 초저온 캐스케이드 냉동사이클의 LNG 열교환기내 냉매와 천연가스의 압력강하가 액화사이클에 미치는 영향을 파악한 후, LNG 열교환기 설계시 압력강하에 대한 기준안을 제시하고자 한다. 이를 위해 HYSYS를 이용하여 초저온 캐스케이드 액화사이클 내 LNG 열교환기의 압력강하에 대해서 시뮬레이션을 수행하였다. 그 결과, 초저온 액화사이클의 압축일량과 성능계수(COP)의 증가로부터, LNG 열교환기 내의 압력강하는 50 kPa정도를 기준 설계 압력강하로 설정할 수 있음을 알 수 있었다.