• Title/Summary/Keyword: 냉난방부하

Search Result 112, Processing Time 0.031 seconds

Energy Performance Assessment Study of Prismatic Solar Hybrid Collector System (Prismatic Solar Hybrid Collector 시스템의 에너지 성능 평가에 관한 연구)

  • Park, J.U.;Kim, K.S.;Lee, E.J.;Chung, M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2003
  • PSHC(Prismatic Solar Hybrid Collector) is a passive solar system composed of prismatic acrly glazing, glazing and ventilating fan. This PSHC system is applied to effectively reduce heating ventilation load as well as lighting load. But so far no method appraising thermal performance of this PSHC system has been developed yet. To assess thermal performance of the PSHC system, a prototype PSHC experimental facility and TRNSYS subroutine type-205 model have been developed in Korea Institute of Energy Research (KIER). The results indicated that l)TRNSYS empirical model of PSHC has been properly modeled with actual performance data, 2)a more reliable source of weather data such as NASA and KIER weather station have been also obtained, and therefore, 3)the annual energy performance of PSHC could be assessed based on this proposed TRNSYS model.

Time Dependent Thermal Load Analysis of the Building with an Airflow Window System (공기식 집열창 시스템이 설치된 건물의 동적부하 해석)

  • Cho, S.H.;Park, S.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF

Dielectric Properties of Epoxy/Layered Nanocomposites (에폭시/나노 층상 복합재료의 유전특성)

  • Park, Jae-Jun;Ahn, Joon-Ho;Hwang, Byung-Joon;Jang, Choo-Moon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.213-214
    • /
    • 2007
  • 에폭시/마이카는 높은 절연성과 강도, 열 안정성 등으로 인하여 고전압 회전기 고정자 권선의 절연재료로 사용되고 있다. 그러나 최근 청단기기의 등장과 냉난방 부하의 증가로 첨두 부하가 크게 증가하여 발전기 부하변동과 자동 정지횟수가 빈번해지고 있다. 이에 따라 기존에 사용되고 있는 절연재료를 획기적으로 발전시킨 새로운 소재의 개발이 필요하게 되었다. 최근 나노기술은 이러한 기술적 한계를 극복할 수 있는 좋은 대안으로 떠오르고 있다. 그리고 나노 크기의 층상화합물은 기존의 재료에 비해 월등한 전기적, 기계적, 열적 특성을 지닌 것으로 알려져 있다. 본 논문에서는 에폭시 기지에 층상 마이카와 점토를 혼합한 나노복합재료를 제조하여 주파수별, 온도별 유전특성을 살펴보았다.

  • PDF

A study on the load management by using Power Line Communication (Power Line Communication을 이용한 부하관리에 관한 기초연구)

  • Park Jae Ho;Hong Seung Man;Rho Dae Seok
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.263-266
    • /
    • 2004
  • 전력선 통신은 전기공급을 위해 기존에 설치되어 있는 전력선을 그대로 이용하는 것으로 통신망을 새롭게 설치할 필요가 없다는 편의성 및 경제적 잇점을 가지고 있다. 최근 전력선 통신 기술을 이용하여 조명제어, 침입탐지와 같은 방범, 가스원격 차단과 같은 방재, 냉난방기기의 제어와 같은 흠오토메이션, 자동원격 검침, 원격모니터링에 적합한 기술로 주목받고 있다 특히 전력선 통신을 이용한 홈네트워크의 구축도 가능할 것이다. 본 논문에서는 전력선 통신의 등장배경과 정의, 핵심기술을 알아보고, 간단한 모뎀과 사용자인터페이스를 제작하여 간단한 부하를 제어함으로써 차후 전력선 통신을 이용하여 가정내 또는 사업체에서의 부하관리의 가능성을 연구하였다.

  • PDF

Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile (모바일 기반 온실 냉난방 부하 산정 프로그램 개발)

  • Moon, Jong Pil;Bang, Ji Woong;Hwang, Jeongsu;Jang, Jae Kyung;Yun, Sung Wook
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.419-428
    • /
    • 2021
  • In order to develope a mobile-based greenhouse energy calculation program, firstly, the overall thermal transmittance of 10 types of major covers and 16 types of insulation materials were measured. In addition, to estimate the overall thermal transmittance when the cover and insulation materials were installed in double or triple layers, 24 combinations of double installations and 59 combinations of triple installations were measured using the hotbox. Also, the overall thermal transmittance value for a single material and the thermal resistance value were used to calculate the overall thermal transmittance value at the time of multi-layer installation of covering and insulating materials, and the linear regression equation was derived to correct the error with the measured values. As a result of developing the model for estimating thermal transmittance when installing multiple layers of coverings and insulating materials based on the value of overall thermal transmittance of a single-material, the model evaluation index was 0.90 (good when it is 0.5 or more), indicating that the estimated value was very close to the actual value. In addition, as a result of the on-site test, it was evaluated that the estimated heat saving rate was smaller than the actual value with a relative error of 2%. Based on these results, a mobile-based greenhouse energy calculation program was developed that was implemented as an HTML5 standard web-based mobile web application and was designed to work with various mobile device and PC browsers with N-Screen support. It had functions to provides the overall thermal transmittance(heating load coefficient) for each combination of greenhouse coverings and thermal insulation materials and to evaluate the energy consumption during a specific period of the target greenhouse. It was estimated that an energy-saving greenhouse design would be possible with the optimal selection of coverings and insulation materials according to the region and shape of the greenhouse.

Development of air-conditioning and drinking water supply system using air-water heat pump (공기-물 히트펌프를 이용한 공조 및 음용수급수시스템 개발)

  • Paek, Yee;Kang, Sukwon;Jang, Jae-Kyung;Kim, Young-Hwa
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.118-118
    • /
    • 2017
  • 지구 온난화에 따른 환경변화로 인하여 최근 10년('02~'11)간 여름의 일수는 4일, 겨울 일수는 16일 각각 증가하였다. 현재 육계사 내의 고밀도 밀집사육으로 인하여 고온스트레스로 하절기 육계의 폐사율이 증가하고 있는 실정이다. 2016년 폭염으로 닭 406.1천수, 오리 15.7천수, 메추리 70천수, 돼지 8천수가 폐사하였다. 이에 혹서기 가축이 약430만수가 폐사하였으며 피해 보상금액 128억원 소요되었다. 본 연구에서는 하절기 고온스트레스 경감과 폐사율 저감을 위해 계사 냉난방 공조와 냉온 음용수 급수를 병행할 수 있는 고효율 환경 개선 시스템을 개발하여 고온스트레스 저감 및 생산성 향상에 목적이 있다. 계사 냉난방 공조 및 냉온음용수 급수 병행 시스템 설계요인을 분석하고 냉난방 공조부하, 냉온수 생산 부하를 고려한 시스템 용량 산정하고 히트펌프, 축열조, 냉난방 및 냉온수 분배장치 등 구성요소로서 공조 및 냉온음용수 급수시스템을 설치하였다. 시스템 용량은 공기-물 히트펌프(10kW,1대), 축열조(10톤), 음용수조(2톤), 열교환기(열교환량,5만kcal/h), 물순환펌프(250W,2대) 및 팬코일유닛(1만kcal/h,4대)으로 시스템 모니터링 및 제어 시스템 개발하여 계사 내 환경, 시스템 성능에 대한 실시간 모니터링을 통하여 저장하였다. 조사항목으로 위치별 온습도, 체중, 사료섭취량, 페사율 등을 조사 분석하였다. 연구결과 계사의 내부온도는 시험구에서는 평균 $25.3^{\circ}C$를 나타내었고 대조구에서는 평균 $28.1^{\circ}C$로서 $2.8^{\circ}C$ 높게 나타났으나 상대습도는 시험구 76.2%, 대조구 75.0%로 큰 차이가 없었다. 냉수급여에 따른 계사 높이별 내부온도는 상하의 온도차가 $4.5^{\circ}C$로 크게 차이가 났다. 육계의 음수량은 혹서기 냉수를 급여한 시험구에서 일일 23.2L, 대조구에서는 21.5L를 섭취하였다. 일일 사료섭취량은 냉수를 급여한 시험구에서 937g, 대조구에서는 725g을 섭취하였다. 사료섭취량은 냉수를 급여한 시험구가 212g 많이 섭취하였으며 사료요구율은 시험구는 1.86, 대조구는 1.91로서 시험구가 낮게 나타났다. 체중은 냉수를 급여한 시험구가 359g 많았으며 증체량은 냉수를 급여한 시험구에서 495g, 대조구에서는 392g으로 나타났다. 폐사율은 냉수를 급여한 시험구에서 84%가 폐사율을 줄일 수 있었다.

  • PDF

A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building (업무용 건물의 이중외피 성능평가를 위한 해석기법의 고찰 - 이중외피 설계안의 에너지 저감 성능 및 환기성능을 중심으로 -)

  • Chung, Hwan-Kyo;Chung, Kwang-Seop;Lee, Yong-Jun;Shin, Seung-Chul;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.168-178
    • /
    • 2012
  • The objective of this study is applied to office buildings to evaluate quantitative evaluation method about performance of double-skin at design stage to establish the basis for the purpose of evaluation performance. Select the evaluation building about design plan for applying the double-skin using the dynamic heat load analysis program the annual heating and cooling load of before and after the double-skin. Using CFD to analyze wind factor and applied ventilation for realistic results. Effects of double-skin to apply, and control techniques that can be done more realistically proposed through to set and control for shade control mode of ventilator and inside cavity wall of double-skin. Apply for the building the double-skin due to interpretation of the annual heating and cooling loads applied to interpret the quantitative effect confirmed the possibility. According to the form of a double skin was confirmed cavity environmental changes.

An Investigation into the Building's Thermal Mass Effect on the Variation of Indoor Temperature (건물의 축열질량이 실내기온 변화에 미치는 영향 평가)

  • Chun, Won-Gee;Jeon, Myung-Seok
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.72-80
    • /
    • 1992
  • This paper is concerned with the accurate estimation of the thermal mass effect on the variation of indoor temperature for residential buildings. To carry out the analysis here, the method called "PSTAR(Primary and Secondary Terms Analysis and Renormalization)" has been extensively used. This method was originally developed by the National Renewable Energy Laboratory(NREL) in the United States. The test results reported here represent two extreme cases of the interior thermal mass, which demonstrate its effect on the interior thermal environment as well as on the overall thermal behavior of the building structure. The monthly heating and cooling loads are also extrapolated by using the renormalized model, which are crucial in designing and refurbishing HVAC systems for the building.

  • PDF

Thermal Interference Modeling in the Aquifer Thermal Energy Storage Systems (대수층 축열 시스템의 열 간섭 모델링)

  • Kim, Jong-chan;Lee, Young-min;Yoon, Woon-Sang;Koo, Min-Ho;Keehm, Young-seuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.596-599
    • /
    • 2009
  • 대수층 축열 시스템(ATES)의 효율은 지중에 저장된 열 사이의 간섭에 의해 결정이 되며, 열 간섭에 영향을 미치는 요인들은 시추공 간 이격거리, 대수층의 수리 전도도, 주입/양수량 등이 있다. 따라서 이 연구에서는 지하수-지열 거동 모델링을 통하여 열 간섭이 일어나는 현상과 열 간섭이 시스템 효율에 미치는 영향을 분석하였다. 모델링 결과로부터 이격거리는 작을수록 그리고 대수층의 수리전도도와 주입/양수량은 클수록 열 간섭이 잘 일어나는 것을 확인하였고, 열 간섭 계수가 1일 때는 시스템 효율이 상대적으로 크게 낮아지고, 열 간섭 계수가 1 미만일 때는 변화가 미미한 것을 확인하였다. ATES 를 이용한 냉난방 시스템을 시공 하고 있는 안성 연구지역에 대한 장기 예측 모델링을 수행 하였다. 모델링 결과 이격거리가 80 m 이고, 주입/양수량이 100 $m^3/day$ 일 때, 시스템 가동 7년경과 뒤 여름철과 겨울철에 계산된 시스템 효율은 각각 36 RT 와 31 RT 로 나타났다. 따라서 주입/양수량을 100 $m^3/day$로 했을 때, 냉난방 대상건물의 필요 부하인 20 RT 를 충분히 충족할 수 있을 것으로 판단된다.

  • PDF