• Title/Summary/Keyword: 냉각 온도

Search Result 1,738, Processing Time 0.044 seconds

A Numerical Simulation of Regenerative Cooling Heat Transfer for the Rocket Engine (로켓엔진의 재생 냉각 열전달 해석)

  • 전종국;박승오
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.46-52
    • /
    • 2003
  • This paper presents the numerical thermal analysis for regeneratively cooled rocket thrust chambers. An integrated numerical model incorporates computational fluid dynamics for the hot-gas thermal environment, and thermal analysis for the liner and coolant channels. The flow and temperature fields in rocket thrust chambers is assumed to be axisymmetric steady state which is presumed to the combustion liner. The heat flux computed from nozzle flow is used to predict the temperature distribution of the combustion liner As a result, we present the wall temperature of combustion liner and the temperature change of coolant.

돼지 도체 냉각방법에 따른 PSE육 발생율 비교

  • Park, Beom-Yeong;Hwang, In-Ho;Kim, Jin-Hyeong;Jo, Su-Hyeon;Lee, Seon-Ho;Kim, Dong-Hun;Lee, Jong-Mun;Kim, Yong-Gon;An, Jong-Nam
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.05a
    • /
    • pp.253-255
    • /
    • 2005
  • 국내 도입 운영되고 있는 돼지 도체 냉각방법과 냉각실의 온도에 따른 PSE 발생율을 비교하여 최적의 냉각조건을 설정하고자 수행한 결과, 도체 냉각방법에 따른 PSE 발생율은 사후 초기 90분간 도체 냉각시 냉수 냉각과 급속냉각방법이 일반적으로 사용하고 있는 완만냉각 방법에 비하여 약 22%정도 PSE 발생율이 낮은 것으로 분석되었다(p<.0001). 사후 초기 90분간 냉각실 온도에 따른 PSE 발생율을 비교한 결과 냉각실 실제온도를 $-5{\sim}7^{\circ}C$로 운영한 경우가 이보다 높거나, 낮게 운영하는 것 보다 $4{\sim}14%$의 낮은 PSE발생율을 보였다(p<0.0001).도체등급판정 후 $3{\sim}5$시간에는 냉각실 온도는 유의적인 차이를 보이지 않았다. 이상의 결과에서 사후 초기 90분간의 온도관리의 중요성을 알 수 있었으며, PSE 발생율과 냉각단축을 줄이기 위해서는 초기 90분간 냉각실온도를 $-5{\sim}7^{\circ}C$로 운영하는 것이 바람직하다고 판단된다.

  • PDF

A Study on the Stack Temperature Profile of a Standing Wave Thermoacoustic Cooler (정재파 열음향 냉각기의 스택 온도구배에 대한 연구)

  • Paek, In-Su
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Investigations of the relation between the stack temperature profile of a standing wave thermoacoustic cooler and the cooling efficiency were performed. Based on the mathematical derivations using the Rott Equation, it was found that the temperature profile along the stack becomes nonlinear as the enthalpy flux passing through the stack increases. It was also found that such nonlinear temperature profiles lower the cooling efficiency. Simulations using a thermoacoustic simulation program called DELTAE showed that the nonlinear temperature profile occurs with a long stack and large cooling load.

Analysis of the Impact of Cooling Methods in High-Performance Processors (고성능 프로세서에서의 냉각 기법의 효율성 분석)

  • Choi, Hong-Jun;Ahn, Jin-Woo;Kim, Cheol-Hong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06b
    • /
    • pp.313-317
    • /
    • 2010
  • 최근에는 반도체 공정 기술의 발달로 인하여 프로세서의 성능은 급속도록 발전하였다. 하지만 프로세서에서 소모되는 전력이 급속도록 증가하고, 이에 따라 발생된 높은 온도는 프로세서 신뢰성에 부정적인 영향을 미치고 있다. 그러므로 최근의 프로세서 설계 시 전력, 온도등도 성능과 함께 중요한 고려사항이다. 프로세서의 신뢰성에 치명적인 영향을 미치는 고온현상을 해결하기 위해서 여러 가지 연구가 이루어지고 있다. 대표적으로 방열 판, 냉각 팬 등을 이용한 기계적인 기법과 동적 온도 관리 기법, 연산 이관 기법등을 적용한 구조적인 기법이 활발하게 연구되고 있다. 이러한 기법들의 적용으로 프로세서의 온도를 효과적으로 제어할 수 있게 되었으나 기계적인 냉각 기법은 냉각 효율성이 높지 않다는 단점이 존재하고, 구조적 설계 기법을 통한 냉각기법은 온도를 제어하기 위해 프로세서의 성능을 저하시키는 치명적인 단점이 존재하기 때문에 두 기법 모두 더 많은 연구가 필요하다. 최근의 프로세서 온도 제어 연구의 초점은 부가적인 장치를 통해 프로세서 내에서 발생 된 온도를 제어하는 기계적인 냉각 기법에서 프로세서 내에서 발생하는 온도를 효과적으로 제어하여 프로세서의 신뢰성과 냉각 비용을 절감할 수 있는 구조적 설계 기법으로 이동하고 있다. 본 논문에서는 연구의 초점이 이동하는 원인에 대해 분석하고자 고성능 프로세서에서의 기계적 냉각 기법의 냉각 효율성을 분석하고자 한다. 실험 결과, 온도를 제어하는 데 있어서 매우 높은 비용($1^{\circ}C$ 감소 당 최대 3.58W, 평균 3.36W)이 소모되는 것으로 나타났다. 향후에는 구조적인 설계 기법의 냉각 효율성을 분석하는 실험을 진행하고자 한다.

  • PDF

Laser cooling and temperature measurement of cesium atoms (세슘 원자에 대한 레이저 냉각 및 온도 측정)

  • 권택용;이호성;양성훈
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.379-384
    • /
    • 2000
  • We cooled cesium atoms below the Doppler cooling limit by laser cooling. For this deep cooling of atoms, the laser frequency was shifted by using the Zeeman shift of an absorption line of cesium. The stabilization of the laser frequency was maintained while the laser frequency was shifted by 40 MHz within 2 ms. The lowest temperature of the laser-cooled cesium atoms was $2.2\muK$\pm$0.5$\muK$in this experiment. We measured the temperature of the laser-cooled cesium atoms as a function of the frequency detuuing and the intensity of the cooling laser. The results agreed well with the ones calculated by two-photon laser cooling theory.theory.

  • PDF

Spaceborne Cryogenic Cooler Development Status (우주용 극저온 냉각기 기술개발동향)

  • Kim, Hong-Bae;Lee, Seung-Yup;Lee, Won-Beom;Kim, Gyu-Sun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.7 no.2
    • /
    • pp.48-58
    • /
    • 2009
  • Since 1960s, cryogenic cooling technologies has been adopted in the development of spacecraft with components that must be cooled to cryogenic temperatures of 2 to 150 K. In recent years this technology has been a substantial growth in the emerging number of programs that include such spacecraft to service scientific, military, and weather observation missions. The cooling of optics and detectors to reduce signal noise in infrared (IR) telescopes is the principal applications of cryogenic cooling technologies. The choice of cooling technologies depends on the desired temperature level, the amount of heat to be removed, and the required operating life. This paper will present the status of modern cryogenic cooling technologies especially for space application.

  • PDF

Estimation of Cooling Rate in Bulk Amorphous Alloys by Separate Cooling Process

  • Kang, Bok-Hyun;Choi, Seong-Pil;Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.30 no.5
    • /
    • pp.167-173
    • /
    • 2010
  • 벌크 비정질 합금의 특성상 점도가 높고, 냉각속도가 빨라 냉각되는 합금의 온도를 직접 측정하는 것은 곤란하므로, 측정에 의하여 냉각속도를 구하는 것은 매우 어렵다. 본 연구에서는 합금의 온도를 직접 측정하는 대신 금형의 온도를 측정하고, 측정된 금형의 온도를 상용 열해석 프로그램을 이용한3차원 계산 결과와 비교, 보정하는 역문제 기법을 사용하여 Cu계와 Zr계 벌크 비정질합금의 냉각속도를 예측하였다. 예측된 냉각속도는 금형온도와 시편의 두께에 따라Cu계의 경우는 284~300 K/s, Zr계는 279~289 K/s로, 초기 금형온도의 영향은 크지 않은 것으로 나타났다. 전산모사 결과와 달리 금형을 수냉한 쪽보다 가열한 쪽의 응고중 냉각속도가 빨라 조직이 더 미세한 것으로 나타났는데, 이는 응고중 금형과 주물간에 에어갭의 형성으로 열전달을 방해 받은 영향으로 사료된다.

A Study on Development of Liquid Cooled Plate for Cooling of a Communication Electronic Device with High Heat Generation (고발열 통신용 전자부품 냉각을 위한 고성능 수냉식 냉각판 개발에 관한 연구)

  • Chang, G.;Park, C.M.;Kim, E.P.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.26-31
    • /
    • 2007
  • 통신용 전자기기에서 대부분의 열은 증폭기에서 발생한다. 일반적으로 증폭기를 냉각하기 위하여 공랭식을 사용하여 발생하는 많은 열을 냉각하였다. 그러나 전통적인 방법은 고성능 콤팩트화 되어가는 추세에서 발열되는 열을 충분히 냉각하기는 부족하다. 본 논문은 고발열 전자부품 냉각을 위해서 수냉식 방법을 사용하였다. 열전달 효율을 높이기 위하여 냉각판에 직접 냉각수를 흐르게하여 접촉저항을 줄였다. 그리고 냉각판의 유로에 대한 배열과 유량의 비의 효과를 조사하였다. 연구를 수행한 결과, 다음과 같은 결론을 얻을 수 있었다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 냉각 성능이 10 mm일 때보다 우수한 것으로 나타났다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 발열 소자 표면 온도 분포가 더욱 안정적으로 나타났으며, 상하부에 설치된 발열 소자 표면 온도가 더 낮게 나타났다. 동일한 유로 직경의 냉각판에서, 열유속 증가에 따른 냉각수의 전열 성능 증가로 인해 전체 발열량의 증가율보다 발열 소자의 온도 증가율이 낮게 나타났다.

  • PDF

형상계수법을 이용한 크라이오펌프용 냉각판의 기체분자 포획능력 해석

  • Im, Jeong-Bin;Gang, Byeong-Ha;Park, Seong-Je;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.86-86
    • /
    • 2011
  • 첨단 공정이 필요한 반도체와 LCD, PDP, LED 등의 디스플레이 및 IT 부품을 제조하는데 필요한 장비의 고성능화와 작업환경의 고청정화에 따른 초고진공펌프의 수요 확대와 앞으로 전개될 한-미 FTA에 따른 시장 확대로 인해 크라이오펌프의 국산화가 시급한 실정이다. 고성능 크라이오펌프를 만들기 위해서는 냉각판을 극저온으로 냉각하기 위한 극저온 냉동기 개발도 중요하지만 냉각판(cryoarray)에 최대한 많은 분자를 포획시키는 것 또한 최우선적으로 고려되어야 할 사항 중 하나이다. 이에 본 논문은 크라이오펌프용 냉각판의 기체분자 포획능력에 대하여 연구하였다. 냉각판의 분자포획능력의 해석은 형상계수법(view factor method)을 이용해 수행하였다. 해석에 이용한 냉각판은 현재 상용화된 모델들 중 원형 중앙판에 45$^{\circ}$ 하향 skirt가 달린 형태이며 8장의 냉각판이 일정한 간격을 두고 아래쪽으로 적층되어있고 이를 기본 모델로 하여 skirt의 형상이 다른 3장의 냉각판을 가진 네 가지 모델을 해석하였다. 해석에 이용한 냉각판의 기체분자 포획능력이 구속된 형상에서 얼마나 우수한가를 알아보기 위해 크라이오펌프의 입구 직경과 냉각판 중앙 원판의 직경비, 냉각판 사이의 거리, 그리고 skirt의 길이를 변화시켜가며 극저온 냉각판에 직접 응축되는 typeII가스와 흡착제가 도포된 부분에 의해 흡착되는 typeIII가스로 분류하여 해석을 수행하고 그 결과를 비교, 분석하였다. 크라이오펌프의 입구 직경과 냉각판 중앙 원판의 직경비가 증가함에 따라 typeII가스와 typeIII가스 모두 기체분자 포획능력이 증가하며 극저온 냉각판 사이 거리의 변화에 따른 기체분자 포획능력은 typeII가스의 경우 극저온 냉각판 사이의 거리가 증가할수록 증가한다. 하지만 typeIII가스는 모델 A, C의 경우 증가하고 모델 B, D의 경우 증가하다가 다시 약간 감소한다. skirt 길이 변화에 따른 기체분자 포획능력은 두 가스 모두 skirt 길이가 증가함에 따라 점점 급격하게 증가하고 모델 B, D는 나머지 두 모델에 비해 큰 값을 갖는다. 기체분자 포획능력을 해석한 결과를 실제 배기속도와 비교할 경우 절대적 수치로써의 비교는 어려우나 각 모델의 형상의 차이에 의한 상대적인 비교는 가능하다.

  • PDF

Study on Evaluation of Local Cooling Performance using Piezoelectric and Thermoelectric Modules (압전소자와 열전소자를 이용한 국소부 냉각성능 평가에 관한 연구)

  • Oh, Hoo-suk;Choi, Byung-Hui
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.478-483
    • /
    • 2017
  • This paper investigated experimentally the performance of cooling systems using thermoelectric and piezoelectric modules for local heating and temperature control, such as a handheld electronic devices. The temperature distribution of the cooling region using thermoelectric modules was measured when the piezoelectric module was and was not with a frequency of 80Hz and 110Hz. The coefficients of performance were also calculated by the temperature results, and the thermo-flow phenomena in the cold region was visualized under the same conditions. The results of the temperature distribution measurements and the coefficient of performance showed that the cooling performance of the cooling system using thermoelectric modules can be improved by operating the piezoelectric module. In addition, when the piezoelectric module was operated based on the result of visualization in the cold region, which was formed by thermoelectric modules, the performance thermoelectric cooling was improved by the thermo-flow formed in the entire cold region as the forced convection of vibration was generated on the local cold region by the piezoelectric module.