• Title/Summary/Keyword: 냉각 능력

Search Result 149, Processing Time 0.023 seconds

Study on Validity of Pre-cooling System for Hydrogen Gas Using Cryocooler Part II: CFD Simulation (극저온 냉동기를 활용한 기체 수소 예냉 시스템 검증에 관한 연구 Part II: CFD 시뮬레이션)

  • YOUNG MIN SEO;HYUN WOO NOH;DONG WOO HA;TAE HYUNG KOO;ROCK KIL KO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.439-446
    • /
    • 2023
  • In this study, the computational fluid dynamics (CFD) simulations were conducted to verify the cooling capacity of the cryocooler used for pre-cooling of hydrogen gas. Based on the experimental results, the effect of the flow rate on a copper pipe attached to the bottom of the cryocooler was investigated. In this study, the temperature data was calculated through the change of boundary condition for heat flux in the copper pipe. In addition, the cooling capacity of the cryocooler for pre-cooling hydrogen gas was considered by calculating the cooling temperature according to the flow rate in the certified operating range. Consequently the pre-cooing system for hydrogen gas was validated with a reasonable accuracy through CFD simulations.

Study on the energy-saving constant temperature and humidity machine operating characteristics (에너지 절감형 항온항습기 운전 특성에 관한 연구)

  • Cha, Insu;Ha, Minho;Jung, Gyeonghwan
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.27-33
    • /
    • 2016
  • The heat recovery system that was applied in this study, is the energy-saving type that can produce the maximum cooling capacity less power in use. In order to have a more precise control function the temperature and humidity of the constant temperature and humidity machine, control algorithm is applied to designed a fuzzy PID controller, and the outside air compensation device (air-cooled) demonstrated excellent ability to dehumidify the moisture, $-20^{\circ}C$ in winter. High efficiency and the low-noise type sirocco fan operate quitely and designed to fit the bottom-up and top-down in accordance with the characteristics of equipment. as a result of experiment data, the conversion efficiency is 95% or more, power recovery time is within 5sec, stop delay time is within 30sec, pump down time is 10sec, pump delay time is 5sec, heating delay time is 5sec, temperature deviation is ${\pm}2^{\circ}C$ (cooling deviation: $2^{\circ}C$, Heating deviation : $2^{\circ}C$), humidity deviation is a ${\pm}5%$ (humidification deviation 3.0%, dehumidification deviation 3.0%). Recently, ubiquitous technology is important. so, the constant temperature and humidity machine designed to be able to remotely control to via the mobile phone, and more scalable to support MMI software and automatic interface. Further, the life of the parts and equipment is extended by the failure.

A Study on the Cascade Hybrid Cooling/Refrigeration Cycle Equipped With Intercooler and Air-Cooled Condenser in Series (인터쿨러와 공랭식 응축기를 동시에 사용하는 냉방-냉동 겸용 캐스케이드 사이클에 대한 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.353-362
    • /
    • 2019
  • Thermodynamic analysis of cascade refrigeration systems has attracted considerable research attention. On the other hand, a system evaluation based on thermodynamic analyses of the individual parts, including the evaporator, condenser, intercooler, expansion valve, etc., has received less attention. In this study, performance analysis was conducted on a cascade refrigeration system, which has an individual cooling and refrigeration evaporator, and equips the intercooler and air-cooled condenser in a series in a lower cycle. The thermo-fluid design was then performed on the major components of the system - upper condenser, lower condenser, cooling evaporator, refrigeration evaporator, intercooler, compressor, electronic expansion valve - of 15 kW refrigeration, and 8 kW cooling capacity using R-410A. A series of simulations were conducted on the designed system. The change in outdoor temperature from 26 C to 38 C resulted in the cooling capacity of the lower evaporator remaining approximately the same, whereas it decreased by 9% at the upper evaporator and by 63% at the intercooler. The COP decreased with increasing outdoor temperature. In addition, the COP of the cycle with the intercooler operation was higher that of the cycle without the intercooler operation. Furthermore, the increase in the upper condenser size by two fold increased the upper evaporator by 4%. On the other hand, the lower evaporator capacity remained the same. The COP of the upper cycle increased with increasing upper condenser size, whereas that of the lower cycle remained almost the same. When the size of the lower condenser was increased 2.8 fold, the intercooler capacity increased by 8%, whereas those of upper and the lower evaporator remained approximately the same. Furthermore, the COP of the lower cycle increased with an increase in the lower condenser. On the other hand, the change of the upper condenser was minimal.

Evaluation of Attention Level on College Students by Application of Cryotherapy in the Posterior Region of Neck (후경부 냉동요법 적용을 통한 대학생의 주의력 수준 평가)

  • Ji Hong Chang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.272-278
    • /
    • 2023
  • Attention, an important element of human cognitive function, is an important cognitive function that focuses only on necessary stimuli from various stimuli through sensory systems. Although various studies have shown that environmental conditions may affect the level of attention, the effect on attention by applying cooling directly to the skin has not been studied much. Differences in attention depending on when and whether cryotherapy was applied during learning and relaxation activities were examined among 36 subjects. The FAIR attention test, a visual attention evaluation tool, was used, and statistical analysis was conducted on the results of the sub-index of FAIR: Performance index, Quality index, and Continuity index. Among participants who performed rest activities, the application of cryotherapy appeared to have no effect on any subindex. Among the participants who performed learning activities, the group that applied pre-cryotherapy (P=469.0, C=435.4)) and the group that applied post-cryotherapy (P=457.4, C=425.4) showed higher Performance index and Continuity index than the group that did not apply cryotherapy (P=335.8, C=301.7). From these results, it can be concluded that cryotherapy maintains the level of alertness and awakens attention, albeit to a limited extent.

Comparisons of Characteristics of Amaranth Starches Isolated from five Cultivars Grown in Korea (국내산 아마란스로부터 분리한 전분의 특성 비교)

  • Choi, Cha-Ran;Choi, Hun-Jae;Kim, Sung-Ran;Lee, Jae-Hak;Shin, Mal-Shick
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.252-257
    • /
    • 2000
  • The physicochemical and pasting properties of amaranth starches isolated from five cultivars, Andy, Suvarna, Nu World, K266-1, K432, grown in Korea, were investigated. The shapes of starch granules were all polygonal and size was in the range $1.14{\sim}1.48\;{\mu}m$ for all five cultivars. X-ray diffractograms were shown typical A type diffraction patterns for all amaranth starches. The protein and crude lipid contents of starches were $0.13{\sim}0.23%$ and $0.01{\sim}0.05%$, respectively. The apparent amylose contents ranged from $2.79{\sim}4.35%$ and the water binding capacities were $128.05{\sim}135.80%$. The transmittances of 0.1% amaranth starch suspensions except K266-1 increased rapidly above $65^{\circ}C$, thereafter increased slowely. The initial pasting and peak temperature ranges of five cultivars by RVA were $71.3{\sim}73.7^{\circ}C$ and $81.5{\sim}84.0^{\circ}C$, respectively. The peak and cooling viscosities followed the order : Nu World>Andy>Suvarna>K432>>K266-1. Nu World was shown the highest peak (166), final (103) and cooling viscosities (30 RVU). K266-I exhibited the lowest setback (-38) of all five cultivars. Gelatinization (To) and peak temperature (Tp) of amaranth starches in DSC thermograms were $65.7{\sim}68.0^{\circ}C$ and $70.6{\sim}75.8^{\circ}C$, respectively. Enthalpies followed the order: K266-1

  • PDF

Study on Confectionary Properties of Chou made with Flour of Rice and Rice-Wheat mixture (미분을 이용한 chou의 제과특성 연구)

  • 김명애;오승희
    • Korean journal of food and cookery science
    • /
    • v.11 no.1
    • /
    • pp.69-76
    • /
    • 1995
  • This study was concentrated on the subject of chou formation and physicochemical characteristics on medium flour mixed with 0, 25, 50, 75, 100% of rice flour in order to clarify the possibility to substitute rice flour for wheat flour on chou preparation. The water holding capacity, swelling power, and maximum viscosity were higher in rice flour than those in medium flour but the initial pasting temperature was equal to 65$^{\circ}C$ in the two flour groups. The ratio of setback during cooling became 0.94 in the rice flour and 1.14 in the medium flour. So, the rice flour showed a slow tendency during gel formation as compared with the medium flour. The volumes of the rice choux were ranged from 80.0% to 89.0% according to the mixing ratio of medium flour as compared with that of the chou of wheat flour. But, the choux formation were increased as much as 108.8% out the paste added gelation of glutinous substance and 124.4% at the paste added Span20 of emulsifier compared to the non-addition treatment. The paste of rice flour added gelatin and Span20 showed better dispersion of components, especially, the small granules of lipid were fairly or plentifully dispersed in the paste added Span20 due to emulsifying activity. In sensory evaluation, the chou of l00% rice flour was inferior to that of medium flour on cavity-forming but the choux of wheat flour mixed with 25%, 50%, and 75% of rice flour were equal or superior to that of medium flour on all characteristics tested such as appearance, surface color, cavity-forming, chewiness, and taste. There were no significant differences on the cavity-forming expansion and taste between choux of rice flour and wheat flour Therefore, the results of this study made conclusion that rice flour would be substituted for wheat flour on the chou preparation.

  • PDF

Application of Geostatistical Analysis Method to Detect the Direction of Sea Surface Warm Flows (해수면 난류수 유동방향 탐지를 위한 지구통계학적 분석기법 적용)

  • Choi, Hyun-Woo;Kim, Hyun-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.1
    • /
    • pp.168-178
    • /
    • 2006
  • In recent years, an ingress of mass jellyfish into cooling water intake system causes interruption of electric power production at the Uljin nuclear power plant. Therefore, monitering and forecast on the mass ingress of marine organisms are demanded as one of the early preventing measurements. Sea water movement is a major factor on the ingress of marine organisms like Moon jellyfish which has weak self-mobile ability. When sea surface flow direction adjacent to the Uljin is the northwest, the jellyfish on the Tsushima warm currents move to the Uljin power plant. To detect the direction of sea surface warm flows, the spatial range with $25km{\times}25km$ is set up and NOAA sea surface temperature(SST) data are collected in this area. For the statistical analysis, the SST data are made as GIS point data and geostatistical analysis of ArcGIS is used. Analyzing directional semivariogram, the anisotropy of the SST point data are calculated and warm flow direction is detected. This experimental results are expected to use as an element technology for the early warning system development of mass jellyfish ingress in power plant.

  • PDF

Development of Backup Calculation System for a Nuclear Steam Supply System Thermal-Hydraulic Model ARTS (Advanced Real-time Thermal Hydraulic Simulation) of the W/H Type NPP (W/H형 원전 시뮬레이터용 핵 증기공급 계통 열수력모델 ARTS(Advanced Real-time Thermal Hydraulic Simulation)의 보조계산체계 개발)

  • 서재승;전규동
    • Journal of Energy Engineering
    • /
    • v.13 no.1
    • /
    • pp.51-59
    • /
    • 2004
  • The NSSS (Nuclear Steam Supply System) thermal-hydraulic programs adopted in the domestic full-scope power plant simulators were provided in early 1980s by foreign vendors. Because of limited compulsational capability at that time, they usually used very simplified physical models for a real-time simulation of NSSS thermal-hydraulic transients, which entails inaccurate results and, thus, the possibility of so-called "negative training", especially for complicated two-phase flows in the reactor coolant system. In resolve the problem, KEPRI developed a realistic NSSS T/H program ARTS which was based on the RETRAN-3D code for the improvement of the Nuclear Power Plant full-scope simulator. The ARTS (based on the RETRAN-3D code) guarantees the real-time calculations of almost all transients and ensures the robustness of simulations. However, there is some possibility of failing to calculate in the case of large break loss of coolant accident (LBLOCA) and low-pressure low-flow transient. In this case, the backup calculation system cover automatically the ARTS. The backup calculation system was expected to provide substantially more accurate predictions in the analysis of the system transients involving LBLOCA. The results were reasonable in terms of accuracy, real-time simulation, robustness and education of operators, complying with FSAR and the AMSI/ANS-3.5-1998 simulator software performance criteria.

Hydrogen Compressor Cycle Analysis for the Operating Pressure of 50 MPa and High Charging Capacity (50 MPa급 대용량 수소압축기 사이클 해석)

  • Song, Byung-Hee;Myoung, No-Seuk;Jang, Seon-Jun;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.66-73
    • /
    • 2020
  • In the hydrogen compression cycle, which is currently being developed, hydrogen is compressed to a very high pressure using a compressor, and then stored and used in a high-pressure vessel. This shows that an increase in the temperature of hydrogen in the vessel due to a pressure rise during the filling process and the pressure fatigue due to the repeated cycle may cause problems in the reliability of the vessel. In this paper, for the entire processes in a 50 MPa hydrogen compression system, theoretical and numerical methods were conducted to analyze the following: the temperature increase of hydrogen in the vessel and the time required to reach thermal equilibrium with the surroundings, the change in temperature of hydrogen passing through the pressure reducing valve, and the required capacity of the heat exchanger for cooling the vessel. The results will be useful for the design and construction of hydrogen compression systems, such as hydrogen charging stations.

A Study on Waste Heat Recycling of Plasma Melting System (플라즈마 용융 공정시의 폐열 재활용 연구)

  • Kim, Seong-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.3
    • /
    • pp.85-90
    • /
    • 2006
  • The purpose of this research is to design an imitation boiler similar to the waste heat boiler installed on a plasma melting furnace in order to acquire a capability of a thermal design as to the circulation of heat and the discharge of noxious gas inside a boiler and to improve the efficiency of a waste heat boiler using the CFD (Computation Fluid Dynamics) program. The position of corrosion and the generation of a clinker inside a boiler due to temperature changes, combustion gas flows, and corrosive gases inside a boiler are examined to design the structure of an efficient boiler and recycle energy. As a result of this research, the boiler installed on a plasma melting furnace met the conditions of design by cooling the combustion gases discharged after the second combustion from an exhaust port, originally at 1,200 degrees Celsius, down to around 450 degrees Celsius. On the other hand, the circulation of corrosive gases (SOx and HCL) may lead to the generation of corrosion or a clinker in the upper and lower parts of an exhaust port more easily than any other parts of a boiler. Accordingly, the corrosion on the inside and outside walls of a boiler may result in a shortened lifespan of a boiler and an inability to recycle waste heat in an efficient manner. A prevention against corrosion at high and low temperatures needs to be considered in detail.

  • PDF