• Title/Summary/Keyword: 냉각판

Search Result 166, Processing Time 0.025 seconds

Analysis of stress and distortion that develop during accelerated cooling of plate (가속냉각시 강판에 발생하는 응력 및 변형에 대한 연구)

  • 김호영;김창영;주웅용;장래웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.952-958
    • /
    • 1988
  • To analyze the nonflatness and residual stress in accelerated cooled plate, a numerical analysis model has been developed. Two factors, i.e. temperature and phase transformation, are considered in calculating the stress distribution that develops during cooling. The plastic strain and plate-buckling, which are often shown in accelerated cooled plate, were determined from this stress. Mean temperature in through thickness direction and temperature difference in width direction are considered in the model to simplify the calculation. The temperature and stress distribution changes caused by phase transformation are involved in terms of the effective specific heat and the effective thermal expansion coefficient. With the model, accelerated cooling of 10mm(t) $^{*}$3000mm(w) plate was simulated. The condition of accelerated cooling was .deg. C/sec from just after hot rolling to 500.deg. C. The initial temperature-difference ratio, .DELTA.Tr, in width direction is an important factor in evaluating the stress distribution. When .DELTA.Tr is 0.08, buckling occurs during cooling and 7kgf/m $m^{2}$ of residual stress develops at the edge of plate. To secure the flatness, .DELTA.Tr should be less than 0.07. Small scaled cooling test was conducted to verify the exactness of the model and the results proved the usefulness of this numerical analysis model.l.

Optimizing the Configurations of Cooling Channels with Low Flow Resistance and Thermal Resistance (냉각유로 형상변화에 따른 유동 및 열저항 최적화 연구)

  • Cho, Kee-Hyeon;Ahn, Ho-Seon;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this study, we investigated the hydrodynamic and thermal performance of constructal architectures on the basis of the mass flow rates for a given pressure drop, and we determined the thermal resistance and flow uniformity. The five flow configuration used in this study were the first construct with optimized hydraulic diameter, the second construct with optimized hydraulic diameter, the first construct with non-optimized hydraulic diameter, second construct with non-optimized hydraulic diameter, and a serpentine configuration. The results of our study suggest that the best fluid-flow structure is the second constructal structure with optimized constructal configurations. We also found that in the case of the optimized structure of cooling plates, the heat transfer was remarkably higher and the pumping power was significantly lower than those of traditional channels.

Performance Test of Liquid Cooling Type Cold Plates for Robot Cooling (로봇 냉각을 위한 수냉식 냉각판의 성능 평가)

  • Lee, Suk-Won;Karng, Sarng-Woo;Hwang, Kyu-Dae;Kim, Seo-Young;Rhee, Gwang-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.189-196
    • /
    • 2008
  • The increase of system weight due to installation of cooling devices adds electrical and mechanical loads of humanoid robot, and in return, results in much heat. Therefore, the weight of cooling system is a critical issue for robot cooling. In this study, we propose non-metallic cold plates to deal with such problems. We compare thermal performances between one metallic cold plate and five different types of non-metallic cold plates. A metallic cold plate is totally made of copper. Five non-metallic PC(polycarbonate) cold plates, which are designed to reduce the overall weight of robot cooling system, are composed of a polycarbonate cover with different types of base plate. The overall heat transfer coefficients per unit mass and thermal resistances are obtained for the cold plates. The metallic cold plate shows the best thermal performance. It is interesting to note that the PC cold plate with an aluminum base plate with 18 channels shows the best overall heat transfer coefficient per unit mass. Most polycarbonate cold plates display fairly comparable thermal performance with more reduced system weight compared to the metallic cold plate.

2단 GM형 맥동관 냉동기 적용 크라이오 펌프 개발

  • Go, Jun-Seok;Park, Seong-Je;Go, Deuk-Yong;Kim, Hyo-Bong;Hong, Yong-Ju;Yeom, Han-Gil;Gang, Min-Jeong;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.85-85
    • /
    • 2011
  • 반도체 생산 공정은 청정 환경을 요구하며, 이를 위해서는 고진공 환경이 필수적인 요소이다. 반도체 생산 라인의 고진공 환경 조성을 위해서는 주로 복합 분자 펌프와 크라이오 펌프가 사용되고 있다. 본 연구에서는 기존의 상용 크라이오 펌프에 사용되던 GM 극저온 냉동기를 맥동관 냉동기로 대체하기 위한 연구를 수행하였다. 맥동관 냉동기는 저온부에 움직이는 부분이 없어 진동이 작고, 신뢰성이 높은 장점이 있어 이를 이용한 크라이오 펌프는 반도체 생산 공정의 공정 정밀도 향상에 기여할 수 있을 것으로 기대된다. 맥동관 냉동기는 크라이오 펌프에 사용하기 위하여 2단으로 구성되며, 저온부가 U자 형상으로 개발되었다. 상용화를 고려하여 로터리 밸브와 위상조절기구가 위치하는 상온부는 일체형으로 제작하였다. 제작된 맥동관 냉동기의 기초 냉각 성능 시험 결과 부하가 없는 조건에서 최저도달온도는 1단과 2단에서 각각 42.53 K과 8.68 K 이었으며, 부하 시험 결과 1단과 2단에서 각각 40 W at 82.97 K, 10 W at 20.51 K의 냉각 능력을 갖는 것으로 측정되었다. 개발된 맥동관 냉동기에 복사차폐막 및 1차, 2차 냉각판을 설치하여 크라이오 펌프를 구성하였고, 기체 질소에 대한 배기 속도 측정 시험을 수행하였다. 배기속도 측정 결과 배기속도는 2차 냉각판의 형상에 크게 영향을 받는 것이 확인되었으며, 약 650 L/의 배기속도를 갖는 것으로 측정되었다. 실험 결과를 바탕으로 크라이오 펌프로 작동시 맥동관 냉동기의 동작 특성 및 배기 속도 향상을 위한 방안을 논의하였다.

  • PDF

Heater Design of a Cooling Unit for a Satellite Electro-Optical Payload using a Thermal Analysis (열해석을 이용한 위성 광학탑재체 냉각 장치의 히터설계)

  • Kim, Hui-Kyung;Chang, Su-Young;Choi, Seok-Weon
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.20-28
    • /
    • 2011
  • The electro-optical payload of a low-earth orbit satellite is thermally decoupled with the bus, which supports a payload for a mission operation. The payload has a cooling unit of FPA(Focal Plane Assembly) which has a thermal behavior increasing its temperature instantly during an operation in order to dissipate a waste heat into the space. The FPA cooling unit should include a radiator and heatpipes with a sufficient performance in worst hot condition, and a heater design to maintain its temperature above a minimum allowable temperature in the worst cold condition. In this paper, we analyzed the thermal requirements and the heater design constraints from the thermal analysis results for the current thermal design of the FPA cooling unit and the design elements of the better heater design were found.

A Study on the Acquisition Technique of Water Retention Characteristics Based on the Evaporation Method and the Chilled Mirror Method for Unsaturated Soils (증발법과 냉각거울법에 의한 불포화토의 함수특성 획득기법 연구)

  • Oh, Seboong;Yoo, Younggeun;Park, Gyusoon;Kim, Seongjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.4
    • /
    • pp.11-20
    • /
    • 2022
  • In order to acquire hydraulic characteristics for unsaturated layers, water retention tests were performed and compared by using the evaporation method, volumetric pressure plate extractor (VPPE) and chilled-mirror dew point method. The evaporation and chilled-mirror method are currently developed experimental technology and measure the water retention curve of unsaturated soils quickly and accurately. In the evaporation and VPPE method, the water retention has been measured and compared until 100kPa matric suction and consequently the result of the evaporation method could be verified. In the chilled-mirror method, the water retention has been measured until high level of matric suction and the overall shape of water retention curves could be obtained. As a result of water retention tests, the representative water retention curves were obtained and the applicability of each test method was discussed. Using both the evaporation and chilled-mirror methods, the soil water retention curve can be acquired reasonably for the whole range of matric suction.

A Study on Freezing Efficiency Improvement of Horizontal-Plate Freezer for Fishing Vessel (어선용 수평 냉각판 냉동장치의 냉동 효율 개선에 관한 연구)

  • Lee, Jae-Chul;Jeong, Ji-Ho;Kim, Byung-Mok;Shin, Sung-Chul;Kim, Soo-Young;Jeong, Bo-Yong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2015
  • The economic efficiency for fishery products can be related to their freshness and the quality. In order to freshly storage the product, freezing equipment system is necessary for fishing vessels. For this purpose, the horizontal plate freezer (HPF) is mostly used. In this research, our major objective is to improve the freezing performance of the HPF. Therefore, it is important to analyse the relationship between the shape of channels and the cooling temperature of the HPF. In order to save calculation time while checking the trend analysis between shape and performance, we used scaled models, and evaluate the cooling temperature of full scale model based on trend analysis results. The produced HPF in domestic was used, and the same operating conditions are considered. Based on this paper, the future research will be a comparison and verification through the experiments.

Heat Transfer Characteristics on Effusion Plate in Impingement/Effusion Cooling for Combustor (연소실 냉각을 위한 충돌제트/유출냉각기법에서 유출판에서의 열전달특성)

  • Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.435-442
    • /
    • 2000
  • The present study is conducted to investigate the local heat/mass transfer characteristics for flow through perforated plates. A naphthalene sublimation method is employed to determine the local heat/mass transfer coefficients on the effusion plate. Two parallel perforated plates are arranged for the two different ways: staggered and shifted in one direction. The experiments are conducted for hole pitch-to-diameter ratios of 6.0, for gap distance between the perforated plates of 0.33 to 10 hole diameters, and for Reynolds numbers of 5,000 to 12,000. The result shows that the high transfer region is formed at stagnation region and at the mid-line of the adjacent impinging jets due to secondary vortices and flow acceleration to the effusion hole. For flows through the perforated plates, the mass transfer rates on the surface of the effusion plate are about six to ten times higher than for effusion cooling alone (single perforated plate). More uniform and higher heat/mass transfer characteristic is obtained in overall region with small gap between two perforated plates.