• 제목/요약/키워드: 냉각탑성능

검색결과 42건 처리시간 0.025초

냉각탑의 선정방법

  • 소헌영
    • 대한설비공학회지:설비저널
    • /
    • 제32권12호
    • /
    • pp.31-37
    • /
    • 2003
  • 냉각탑의 성능저하방지와 에너지절감 및 민원 발생방지를 위한 형식, 용량, 배치, 설치의 최적 선정 방안을 제시한다.

  • PDF

기존 냉각탑의 성능개선 방안

  • 권오익
    • 대한설비공학회지:설비저널
    • /
    • 제32권12호
    • /
    • pp.38-45
    • /
    • 2003
  • 본 글은 공조용 냉각탑에 대한 열적성능에 국한하여 성능저하 요소를 알아보고 그 개선 방안을 제시하고자 한다.

  • PDF

충전재 형상에 따른 냉각탑 성능비교에 관한 연구 (Comparison of performance of cooling tower with various shape of packings)

  • 이강현;최우영;이재헌;소헌영
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.358-367
    • /
    • 1998
  • Since the performance of cooling tower is strongly dependent on the thermal performance of the packing, the evaluations of heat transfer rate and fan power from various packing have attracted intense interest. In the present study, two new packings have been devised and their performances have been compared with those of two existing packings to find better shape characteristic. It is found that one of the existing packings, which showed high heat transfer rate and medium fan power due to zig -zag flow passages and highly irregular surfaces, should be adapted.

  • PDF

기계통풍식 냉각탑 유닛의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Cooling Tower Unit for Mechanical Draft)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.642-648
    • /
    • 2021
  • In this paper, an experimental study was conducted on the performance of the cooling tower. In order to improve reliability in the cooling tower performance test, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. Therefore, the measurement result of the performance experiment is not an actual value, but a reasonable estimated value. The measurement uncertainty for the test was calculated and the measured results were presented.

냉각탑 병용 하이브리드 지열 히트펌프 시스템의 성능 분석 (Performance Analysis of Cooling Tower-Assisted Hybrid Ground-Coupled Heat Pump (HGCHP) System)

  • 손병후;이두영;최재호;민경천
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.19-26
    • /
    • 2016
  • 하이브리드 지열 히트펌프 시스템은 열원을 안정적으로 유지하기 위해 보조 히트싱크나 보조 열원을 활용한다. 본 연구에서는 병원 건물에 설치한 지열-냉각탑 하이브리드 시스템의 냉난방 성능을 분석하였다. 시스템에 각종 센서와 계측 장비를 설치하였으며, 2014년 2월부터 2015년 2월까지 측정한 데이터를 이용하여 성능을 분석하였다. 냉방 기간 중, 냉수 공급 온도는 평균 $11.7^{\circ}C$이었으며, 설계 온도인 $12^{\circ}C$를 넘지 않았다. 또한 난방 기간 중에는 일평균 $39^{\circ}C{\sim}40^{\circ}C$의 온수를 공급하였다. 지열 히트펌프만의 월 평균 성능지수는 3.8에서 8.4의 범위에서 변하였다. 반면 냉각탑을 포함한 하이브리드 지열시스템의 월 평균 성능지수는 2.6에서 6.6 사이에서 변하였다.

대향류형 냉각탑의 탈설계 성능해석 (Off-Design Performance Analysis of a Counterflow-Type Cooling Tower)

  • 신지영;손영석;한동원
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.191-198
    • /
    • 2002
  • Cooling tower design procedure was set up using conventional Merkel theory, The design data could be different depending on the characteristic curve that the engineer chose. It reveals that the consistent and reasonable criteria are required based on the exact information of the cooling tower Performance. In this study, an off-design performance analysis program for a counterflow-type cooling tower was developed and verified by comparing with experimental data. Also, the off-design performance with various operating conditions was analyzed.

냉각성능 분석오류 (Mistakes of Cooling Tower Performance Analysis)

  • 권오익
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.397-404
    • /
    • 2004
  • 냉각탑이란 석유화학플랜트, 철강플랜트 등과 같은 생산 공정이나 냉동기를 비롯한 각종 기계장치에서 발생된 열을 수냉식 열 교환장치에서 물로 직접 냉각시킬 때 공정유체의 열을 전달받아 데워진 물을 대기의 공기와 직접 접촉시켜 물의 증발 잠열을 이용하여 원하는 온도로 냉각시켜 주는 기계장치이다.(중략)

가정용 흡수식 냉온수기용 냉각탑의 성능특성 (Performance Characteristics of Cooling Tower on Small Absorption Chiller)

  • ;김은필;정석권;민경현;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.

연속화학평형 모델을 이용한 이온교환 모델링 (Ion Exchange Modeling with Sequencing Chemical Equilibrium)

  • 이인형;안현경
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2002년도 추계학술발표논문집
    • /
    • pp.306-308
    • /
    • 2002
  • 원자로냉각재계통(Reactor Coolant System) 및 사용 후 저장조정화계통(Spent Fuel Pool Purification System)에는 양ㆍ음이온 교환수지가 충진된 혼상 이온교환수지탑을 설치하여 계통수에 존재하는 방사성 핵종을 제거하고 있으며, 정화율을 나타내는 제염계수(Decontamination Factor)가 특정값 이하이면 수지를 교체하고 있다. 그러나 특정 핵종에 대한 제염계수가 수지 사용기간에 관계없이 기준값 이하로 나타나고 있고, 수지탑의 성능을 예측하고 있지 못하는 실정이다. 원자력발전소 1차 계통에 설치되어 불순물을 제거하는 이온교환 수지탑에 대한 연속화학평형모델에 적용한 결과 수지탑에서 이온 용출은 수지에 대한 이온 선택도 순서와 동일하고 냉각재계통에는 붕산이 주성분이므로 음이온수지에서 붕산이 가장 먼저 누출된다. 그리고 붕산으로 포화된 음이온수지의 음이온 불순물 제거능력은 저하되지 않으며, 리튬으로 포화된 양이온수지의 양이온 불순물 제거능력은 저하된다.