• Title/Summary/Keyword: 냉각부

Search Result 508, Processing Time 0.025 seconds

Design and Fabrication of Full-Scale Regenerative Cooling Combustion Chamber (${\varepsilon}$=12) of Liquid Rocket Engine for Ground Hot Firing Tests (지상연소시험용 실물형 재생냉각 연소기(확대비 12)의 설계 및 제작)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Seo, Seong-Hyeon;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.114-118
    • /
    • 2007
  • Design and fabrication of a 30-tonf-class full-scale regenerative cooling combustion chamber of a liquid rocket engine for a ground hot firing test are described. It has chamber pressure of 60 bar and nozzle expansion ration of 12 and manufactured to have a single welded structure of· the mixing head and the chamber. The material of the mixing head is STS316L which has excellent mechanical property in cryogenic condition. The chamber comprise of the cylinder, nozzle throat, and 1st/2nd nozzle parts. The material of the inner jacket is copper alloy/STS329J1/STS316L and that of the outer jacket is STS329J1. The components of· the combustor were manufactured by mechanical processing including lathing, milling, MCT, rolling and pressing. The machined components were integrated to a single body by means of general welding, electron beam welding(EBW), and brazing.

  • PDF

Design and Fabrication of a Pilot Scale Continuous Kimchi Pasteurizer (Pilot Scale 연속식(連速式) 김치순간살균(瞬間殺菌) 장치(裝置)의 설계(設計) 및 제작(製作))

  • Kim, Kong-Hwan;Gil, Gwang-Hoon;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.83-89
    • /
    • 1984
  • In order to study the feasibility of industrial application of Kimchi juice separation-pasteurization method, a pilot scale Kimchi pasteurizer was designed and fabricated. The apparatus consisted of five sections: Kimchi juice separation-mixing, holding, precooling and cooling sections. Stainless steel pipelengths required for the heat exchanging sections were determined based on an equation, $W{\;}C_p{\;}T{\;}={\;}U(2{\;}RL){\;}T_{1m}$. Overall heat transfer coefficients in preheating, holding, precooling and cooling sections were 875, 1398, 2036, and $288{\;}kcal/m^2h^{\circ}C$ at the flow rate of 4 l/min, respectively, and temperature profiles of each section were in good agreement with those predicted from design criteria. A preliminary test using Chinese radish Kimchi demonstrated that this method can effectively be used in commercial processing of kimchi.

  • PDF

THERMAL DESIGN OF A PROTOMODEL SPACE INFRARED CRYOGENIC SYSTEM (적외선 우주망원경 냉각시스템 시험모델 열설계)

  • Yang Hyung-Suk;Kim Dong-Lak;Lee Byoung-Seob;Kim Geon-Hee;Lee Dae-Hee;Pak Soo-Jong;Nam Uk-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.2
    • /
    • pp.153-160
    • /
    • 2006
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cry-ocooler has been designed. The PSICS has an IR sensor inside the cold box which is cooled by a stirling cryocooler with refrigeration capacity of 500mW at 80K in a vacuum vessel. It is important to minimize the heat load so that the background thermal noise can be reduced. In order to design the cryogenic system with low heat load and to reduce the remained heat load, we have performed numerical analyses. In this paper, we present the design factors and the results obtained by the thermal analysis of the PSICS.

Numerical Analysis for Cooling Condition of a Lamp House in the Exposure Device by Response Surface Methodology (반응표면분석법을 이용하여 노광기 램프하우스의 냉각조건 수치해석)

  • Kim, Youngshin;Jeon, Euysik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1265-1271
    • /
    • 2014
  • The lamp cooling system of the exposure has effect on the exposure efficiency and device lifetime. In this paper, we performed the numerical analysis about the thermal flow in the lamp housing of the exposure apparatus for the cooling air inflow rate. We set up the velocity of cooling air of side and bottom as the independent variables because cooling performance of the lamp housing is affected by the velocity of the cooling air side and bottom. The cooling state of lamp housing depend on three dependent variables; the temperature at top mirror and exhaust gas, ellipsoidal mirror. Response surface methodology was used in order to establish the efficient cooling analysis plan. The regression equation predicting the variables temperature of lamp housing according to the cooling air velocity were drawn. The velocity of cooling air to reach the optimum temperature of the lamp housing were derived.

Heat Transfer Characteristics under Recirculation zone of Ramjet Combustor (재순환 영역이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Lee, Keon-Woo;Oh, Min-Keun;Ham, Hee-Chul;Hwang, Ki-Young;Cho, Hyung-Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.9-17
    • /
    • 2007
  • This experimental study has been conducted to investigate the effect of the recirculation zone on the multi-slot film cooling in the ramjet combustor. The recirculation zone which is generated by the protrusion tip on the entrance of the coolant flow path affects on the first slot. Velocity fields, dimensionless temperature fields and adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.

Temperature Characteristics Analysis of Major Heating Region According to Cooling Device Location of Grid-Connected Photovoltaic Inverter (계통연계형 태양광 인버터의 냉각장치 위치에 따른 주요발열부 온도특성 해석)

  • Kim, Min-Seok;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.7
    • /
    • pp.799-804
    • /
    • 2014
  • To combine to the power transmission, photovoltaic inverter is demanded, because the photovoltaic system is generated direct current power. However, photovoltaic inverter is sensitive to high temperature. In the temperature rising such as at noon and on summer, efficiency of machine is decreased due to the loss increment. Because this problem causes national energy loss according to the expanding the photovoltaic industry, countermeasure is demanded. There, in this paper, we installed a cooling system using a thermoelement regardless of the temperature. Also, we analyze the cooling effect according to the position of two fans which improve the effect maximize.

Film cooling Effects on Wall Heat Flux of a Subscale Calorimetric Combustion Chamber (막냉각량에 따른 축소형 칼로리미터의 열유속 특성에 관한 연구)

  • Kim, Jong-Gyu;Lim, Byoung-Jik;Seo, Seong-Hyeon;Han, Yeoung-Min;Kim, Hong-Jip;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.93-99
    • /
    • 2006
  • The effects of the changes of a film cooling mass flow rate and operating conditions on wall heat flux characteristics of a subscale calorimetric combustion chamber were investigated by experiment and numerical analysis. At the nominal operating condition, with the film cooling mass flow rate being 10.5 percent of a main fuel mass flow rate, maximum heat flux at the nozzle throat was measured to be 30 percent lower than that without the film cooling. For the relatively higher mixture ratio and chamber pressure condition, maximum heat flux at the nozzle throat was increased by 31 percent compared to that of the nominal condition test without film cooling.

MIRIS 우주관측 카메라 Noise Test

  • Park, Yeong-Sik;Lee, Dae-Hui;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Pyo, Jeong-Hyeon;Nam, Uk-Won;Park, Jang-Hyeon;Lee, Seung-U;Matsumoto, Toshio;Han, Won-Yong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.126.2-126.2
    • /
    • 2011
  • MIRIS(Multipurpose InfraRed Imaging System)는 과학기술위성 3호의 주 탑재체이며 2012년 하반기 발사예정이다. MIRIS 우주관측 카메라는 0.9-2.0 ${\mu}m$ 영역에서 3.67 deg. x 3.67 deg. FOV로 우리 은하평면 survey 관측과 우주배경복사(CIB) 관측을 수행할 것이다. 현재 MIRIS는 비행모델 개발 마무리 단계에 있으며, 검교정 시험, 열-진공 시험, 진동 시험 등을 수행하고 나면 2011년 말 위성 본체와의 조립을 진행할 것이다. 망원경이 복사냉각(Passive Cooling)을 통해 200K 이하로 냉각되면, dewar에 설치된 소형 냉각기를 가동하여 적외선 센서를 90K 정도로 냉각한다. MIRIS 우주관측카메라에는 PICNIC($256{\times}256$ pixel) 센서를 사용하였고, 상온과 냉각된 상태에서의 노이즈 특성을 측정하였다. PICNIC 센서와 dewar내부를 냉각하기 위해 RICOR사의 K-508 micro stirling cooler를 사용하는데, cooler가 동작하면서 전자부에 영향을 주어 주된 잡음으로 나타남을 확인하였다. Cooler에서 발생하는 잡음을 최소화 하기위해 fanout B/D와 LVPS 부분을 개선하였으며, 본 발표에서는 잡음 측정 결과에 대해 논의 하고자 한다.

  • PDF

Estimation of PTC (Powertrain Cooling) Performance with Heat Rejection Rate (열방출량 (Heat Rejection Rate)을 이용한 PTC (Powertrain Cooling) 성능 추정)

  • Min, Sunki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3030-3034
    • /
    • 2015
  • It is important to consider powertrain cooling performance, when engine is applied to new vehicle. If the performance is poor, engine will be damaged by overheating. But, the development timing of engine is faster than timing of vehicle, it is difficult to test the cooling performance of new engine and vehicle. In this study the powertain cooling performance was estimated with some test and calculation data. First, the heat rejection test was conducted. From this test, the heat rejection data at required rpm and load was acquired. Second, coolant flow test was conducted. From this test coolant flow rate to radiator was measured. Then engine torque and rpm was calculated from vehicle load and speed. Vehicle load and speed was calculated from test mode. Then by comparing these data, the powertrain cooling performance was estimated.

기기냉각수 최저온도와 정지냉각계통 유량조절밸브 개도에 관한 설계분석

  • 김도현;이중섭;오종필;오광석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.444-449
    • /
    • 1995
  • 한국형 표준 원자력발전소의 정지냉각운전시 최대냉각율은 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr)로 기술사양서에 규정되어 있다. 정지냉각운전 냉각율에 가장 큰 영향을 미치는 2가지 중요한 변수는 정지냉각계통 열교환기를 지나는 원자로냉각재 유량과 기기냉각수의 온도다. 이중 열교환기를 지나는 원자로냉각재 유량은 butterfly형 정지냉각계통 유량조절밸브의 개도에 의하여 조절되는데 개도에 따른 throttle 능력이 중요한 인자다. 또 기기냉각수의 온도는 해수온도의 변화에 따라 편차가 발생하므로 유량조절밸브의 개도와 기기냉각수 온도의 상관관계에 따라 냉각능력이 달라진다. 본 논문에서는 현 울진 3&4호기 정지냉각계통 열 교환기 및 조절밸브 둥의 설비를 기준으로 기술사양서 상의 냉각율 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr) 유지가 가능한 최저 기기냉각수의 온도를 찾아보았고, 아울러 기기냉각수의 온도와 조절밸브의 개도 사이의 관계를 조사하였다. 그 결과 현재의 울진 3&4호기 조절밸브를 최저개도로 조절할 때 약 57$^{\circ}$F(13.9$^{\circ}C$)의 기기냉각수가 공급되어도 냉각율 제한치를 넘지 않는 것으로 분석되었다. 한편, 최저조절가능 유량이 약 2000 gpm(7570 l/min)일 경우에는 낮은 기기냉각수가 공급될 경우 최대냉각율을 초과하므로 한 train을 정지시키고 한 train만으로 운전할 것을 고려하여야 할 것으로 보인다. 이 경우 최저 약 56.5$^{\circ}$F(13.6$^{\circ}C$)의 기기냉각수가 공급되어야 한다. 본 논문의 분석결과는 향후 기기설계사양서나 운전지침서 등에 반영되어 실제 발전소 설계 및 운전절차 수립에 기여할 수 있을 것으로 생각된다.공감대의 형성이 요구된다. 질적 측면에서는 공원 녹지의 기능성의 회복이라는 측면과 시대에 부합되는 새로운 기능 및 가치의 부여가 필요하며, 이를 위해서는 공원의 매력, 공원의 시설기능 증진, 녹지의 질의 향상 및 녹지 가치의 증진에 대한 다양한 시책이 요구된다. 구성적 측면에서는 공원녹지의 개별적 존재보다는 공원 녹지를 상호간 유기적인 계통을 확보하여 공원 녹지의 네트워크를 형성하여 도시 속의 산재된 고립된 섬으로서의 공원 녹지가 아닌 시민생활에 늘 가까이 있는 생활 속의 공원녹지로 재편되어야 한다. 이러한 정책의 의제는 양적 측면에서 보전(CONSERVATION)과 창출(CREATION), 질적 측면에서 쇄신(RENOVATION)과 복구(RESTORATION), 그리고 구성적 측면에서 공원 녹지의 연결(CONNECTION)과 시민 참여에 의한 운동(MOVEMENT)이라는 정책 개념의 구현을 통해 가능하다. 이러한 정책 개념과 의제를 가지고 서울시 공원 녹지 정책을 구체화시키기 위해서 푸르름의 새로운 탄생이라는 기치 아래 풍요로운 서울, 사랑 받는 공원, 생활 속의 녹지의 3대 목표, 공원 녹지의 보전, 잠재 공원 녹지의 창출, 공원의 활성화, 녹지의 복구, 경관 보전 및 복구, 공원 녹지의 네트워크, 도시 녹화의 7대 과제를 설정하고 미시설 공원 녹지 집행, 개발 사업시 공원 녹지의 확보, 환경 녹지의 총량 보호 관리, 도시 소공원 개발, 역사 문화 공원 조성, 하천 공간 복원, 공원 시설 기능 개선, 이용 프로그램 개발, 공원 관리 개선, 환경 피해 녹지의 회복, 도시 환경 림 조성, 녹지 기능 증진, 도시 자연 경관 보전, 공원 녹지체계 구성, 공원 녹지 공급 균형, 주변 환경 녹화, 가로 녹화의 17개 시책을 제안하였다. 이러한 정책사업의 원활한 추진을 위해서는 기존의 관주도의 일방적인 공원 녹지 행정이 아닌 시민의 참여를 통한 시민이 함께 하는 정 책 사업의 추진이 요구되며, 특히 민간 부문의

  • PDF